TIPS FOR LONG MEMBRANE LIFE
1.
Replacement of 1 micron sediment filter once every 6 months.This will pre vent the
mem brane from fouling due to silt or sediment depositing on the membrane.
2.
Replacement of 1 micron carbon block filter at least once every 6 months or before
chlorine breakthrough occurs . This will ensure good membrane life and protect the
membrane from chlorine damage.
3.
Membrane should not be operated at lower than the recommended concen trate to
purified water ratios, as described on page 10.
4.
Operating reverse osmosis systems on softened feed water greatly reduces
the chances of membrane fouling.
5.
Use the optional flush valve kit after each use of the system to extend membrane life .
STORAGE
1.
It is recommended that you store your Eliminator RO System in a cool
place when not being used.
2.
Your Eliminator RO System must be protected from freezing or temperatures
above 100° F (38°C).
CHOOSING A MOUNTING LOCATION
When considering a location for the installation of the System, consider the following
factors:
Light
Sources
1. Most of the components of this system are plastic and are subject to
damage by ultra- violet light from the sun and other sources such as metal
halide lighting.
2. Algae is more likely to thrive inside the clear filter housings when exposed to
bright light.
3. Avoid installing this unit in bright light or direct sunlight.
Temperature Extremes
1. The unit must be kept out of areas that are subject to freezing temperatures.
2. High temperatures greater than 100° F (38° C) must be avoided. If the unit is
used outside, avoid putting the system in direct sunlight or connecting it to a
garden hose that may be exposed to sunlight.