FRESH WATER
STEP 1: Unscrew the third position housing (MaxCap DI) and the fourth position housing (Silica-Buster DI) from the system
and remove the DI Cartridges. Then, re-install the empty housings back onto the system.
STEP 2: Connect the 3/8” Black Line to the cold water line by using either the garden hose adapter, which is provided
with the system, or a Feed Water Adapter.
STEP 3:
PURE WATER FLUSH CYCLE INSTALLATION USING THE HIGH & LOW FLOAT SWITCHES:
A. Install both the High and Low Floats onto a open container like a Rubber Maid
TM
trash can. The floats can be
mounted by drilling a 5/8” hole. (The High Float shuts down the system, while the Low Float turns the system
on).
B. Connect the floats to the “Y” adapter.
C. Attach the 3-pin connector on the float switches to the HI-REC MODULE.
NOTE: Floats are to be mounted horizontal when dry and float up when wet. In most instances we
recommend locating the low float approx. half way down your reservoir. DO NOT OVERTIGHTEN
when installing the floats.
STEP 4: For now, direct both the 3/8” blue (product) line and the yellow (waste) line to drain.
STEP 5: Open the cold water line, where the black line is connected to. Plug in the 24 V transformer to the UHE Module
and connect to power.
NOTE: Floats have to be installed in a FRESH WATER storage container.
NOTE: This system MUST be connected to the floats to operate the Flush Cycle. Failure to install
the pure water flush connection for this unit will void any warranty.
SET-UP PROCEDURES
Garden Hose
Adapter
Feed Water
Adapter
“Y” adapter