![SpectraPure CSPDI-180-AF Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/spectrapure/cspdi-180-af/cspdi-180-af_installation-and-operating-manual_1343941011.webp)
SpectraPure
®
Inc
.
Fax 480.894.6109 Fax us toll-free 1.877.527.7873
[email protected] www.spectrapure.com
11
SpectraPure
®
SYSTEM INSTALLATION & INITIALIZATION:
1. Most of the components of this system are plastic and are subject to damage
by ultraviolet light from the sun and other sources such as metal halide lighting.
2. Avoid installing this unit in an area where it may be subjected to bright light
or direct sunlight, as algae is more likely to thrive inside the clear filter housings
when exposed to bright light. The unit must be kept out of areas that are
subject to freezing temperatures.
3. High temperatures greater than 113° F (45° C) must be avoided. If the unit is
used outside, avoid putting the system in direct sunlight or connecting it to a
garden hose that may be exposed to sunlight.
4. Attach the black tap water tubing to the left side of the Sediment Filter Housing
(See page 6 or 7).
5. Attach the yellow drain line to the “Y”- connector at the rear of the system. This
“Y”- connector already has a yellow and green tube attached to it.
6. Attach the blue product line to the front port of the right-hand DI housing.
7. Attach the black tubing and elbow(s) to the membrane housing cap(s).
8. Unscrew the right DI housing and remove the DI cartridge. Reconnect the
empty housing to the threaded cap. Hand tighten.
9. Attach the garden hose adapter
(connected to the black tubing)
to your cold
water source. Never run hot water (greater than 113° F/45° C) through the system.
10. A provided ball valve can be located at a convenient place on the black tap
water line. Cut the black tubing in two and reconnect the two cut ends with
the ball valve.
11. Place the
yellow concentrate (waste) tubing
and the
blue purified (product)
water tubing
temporarily into a drain. Do not restrict flow from these lines.
12. There is a group of red, white, green and blue sensor wires. At the end of the
wires, you will find a small white connector. Just insert the connector into the
receptacle on the top of the TDS meter. You can then use the Velcro on the
back to mount the meter whereever it’s convenient. For example, you may
even mount it on a wall for easier viewing.
13. Open the cold water supply valve. The pressure should not exceed 80 psi.
14.
Check the system to ensure that all fittings are tight and leak-free
before leaving the system unattended. (If anything is leaking, contact
SpectraPure for assistance.)
15.
Run both the blue and yellow tubings down the drain for an hour, then
reinstall the DI cartridge. Hand tighten.