background image

SpectraLink Corporation 

Installation  

 

NetLink OAI Gateway 

2.  The NetLink OAI Gateway  

The NetLink OAI Gateway enables third-party applications to communicate directly with 
up to 10,000 NetLink Wireless Telephones, allowing users to retrieve and respond to 
information using their Wireless Telephones.  
The NetLink OAI Gateway is available in two models and several scaled capacity levels, 
please be sure that the OAI Gateway being configured has the appropriate capacity for 
your implementation. 

SpectraLink 

Model Number 

Maximum 

Number of 

Users 

MOG600 64 
MOG710 128 
MOG720 256 
MOG730 512 
MOG740 1,024 
MOG750 10,000 

As shown in the diagram below, a single NetLink OAI Gateway is connected to the site’s 
Local Area Network (LAN) via an Ethernet switch. The connection to the OAI 
Application Server can be accomplished by a direct connect (RS-232) or through the 
Ethernet connection, but may run only via one connection at a time. 
During setup, the IP address of the NetLink OAI Gateway must be set. Once the IP 
address is established, the Gateway can be accessed by the application server via the RS-
232 port or the LAN via telnet. 

Alternate RS 232 
cable for initial 
setup 

RS 232 cable 
for ongoing 
operation 

RS-232 
port  

Configuration

Terminal

(PC)

RS-232 
port  

RS-232

port

Application

Server

(PC)

LAN 

Ethernet 

switch 

 
OAI 
Gateway 

Part Number: 72-0078-

0

7-A.doc 

Page 10 

Содержание MOG600

Страница 1: ...Installation NetLink Open Applications Interface OAI Gateway Part Number 72 0078 07 Issue A ...

Страница 2: ...ofits arising out of or related to this document or the information contained in it even if SpectraLink has been advised knew or should have known of the possibility of such damages Trademark Information SpectraLink LinkPlus Link Wireless Telephone System NetLink Telephony Gateway NetLink Wireless Telephone NetLink SVP Server SpectraLink Voice Priority ccLink Wireless Telephone System are trademar...

Страница 3: ... SCA 416 SCA 516 Battery Charger Models PTC 400 conform to Directive 89 336 EEC for Electromagnetic Compatibility Compliance was demonstrated to the following specifications as listed in the official Journal of the European Communities EN 50081 1 1992 Emissions EN 55022 Radiated Class A EN 55024 Emissions EN 50082 1 1997 Immunity IEC 801 2 Electrostatic Discharge IEC 801 3 RF Radiated IEC 801 4 Fa...

Страница 4: ...ents Note concerning the Wireless Telephones This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this equipment not approved by SpectraLink Corporati...

Страница 5: ...our calling area If your telephone equipment causes harm to the telephone network the telephone service may discontinue your service temporarily If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be informed of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipm...

Страница 6: ...ny repairs or alterations made by a user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be par...

Страница 7: ...plication Server via RS 232 port 15 3 5 Connect the NetLink OAI Gateway to Application Server via the LAN 16 3 6 Connect the NetLink OAI Gateway to Application Server via a modem 16 4 THE MAIN MENU 17 4 1 NetLink OAI System Main Menu 17 4 2 IP Systems Main Menu 18 5 CONFIGURATION PROCEDURES 19 5 1 OAI Box Configuration 20 5 2 Network Configuration 21 5 3 OAI Line Configuration 23 5 4 Telephone Lin...

Страница 8: ... NetLink OAI Gateway 8 CERTIFICATION TEST 33 9 SOFTWARE MAINTENANCE 34 9 1 Software Updates for MOG700 Systems 34 9 2 TFTP Software Updates for MOG600 Systems 36 10 WIRELESS DEVICE PLANNING WORKSHEET 37 Part Number 72 0078 07 A doc Page 8 ...

Страница 9: ...s please contact our Customer Support Hotline at 800 775 5330 The Hotline is open Monday through Friday 6 00 AM to 6 00 PM Mountain Time 1 2 Icons and Conventions This manual uses the following icons and conventions Caution Follow these instructions carefully to avoid danger Note these instructions carefully NORM This typeface indicates a key label or button on the OAI Gateway or Wireless Telephon...

Страница 10: ... MOG730 512 MOG740 1 024 MOG750 10 000 As shown in the diagram below a single NetLink OAI Gateway is connected to the site s Local Area Network LAN via an Ethernet switch The connection to the OAI Application Server can be accomplished by a direct connect RS 232 or through the Ethernet connection but may run only via one connection at a time During setup the IP address of the NetLink OAI Gateway m...

Страница 11: ...ta Device Wireless Telephones Access Point Wired Telephones Direct Connect 3 rd Party Applications Paging Controller Nurse Call Systems Industrial Controllers See Application Note for Specific Installation Server for 3 rd Party OAI Application NetLink OAI Gateway Wired telephone system LAN Backbone LAN based 3rd Party Applications Email Server LAN Clients Internet OAI protocol RS 232 optional RS 2...

Страница 12: ...E rror LED lit when the system has detected an error Status LEDs indicate system messages and status 1 heartbeat indicates NetLink OAI Gateway is running 2 3 and 4 currently unused 5 System master Model MOG7xx Offered in scaled increments to support up to 10 000 users NETWORK RS 232 port STATUS 2 1 5 4 3 E R R O R C O L A C T L N K O K S Model MOG6xx Supports up to 64 users RS 232 port NET 2 1 E 5...

Страница 13: ...lug the power adapter into an outlet or outlet strip 3 Apply power to the Gateway The error LED should be off LED 1 should be blinking New System Installation If this is a new system installation place power up and test the OAI Gateway when the rest of the system is tested See the Setup and Maintenance NetLink Wireless Telephone document for your system for more information Installing in an Existi...

Страница 14: ...rminal 04830130 3 Type the following command on the terminal or PC keyboard 0255CC CTRL M CTRL J Note that this command will not display on the screen as it is typed 4 The Login prompt should display If you made an error entering the command string the message for Ill Formed Packet will display a series of numbers followed by some version of the command you typed Repeat Steps 2 and 3 until you see...

Страница 15: ...routine 3 4 Connect the NetLink OAI Gateway Application Server via RS 232 port Some applications or systems may require an RS 232 connection between the application server and the NetLink OAI Gateway If your applications have the ability to communicate OAI messages over TCP IP and do not require a serial connection the RS 232 cabling is not required and you may use the LAN connection port 5456 via...

Страница 16: ...OAI Gateway to function on the LAN Follow the application s instructions to identify the Gateway to the application Application Server PC LAN Ethernet switch OAI Gateway 3 6 Connect the NetLink OAI Gateway to Application Server via a modem In some situations a modem is used for remote administration of the NetLink OAI Gateway Connect the modem to the Gateway s serial port using a cable that confor...

Страница 17: ...ink OAI System Main Menu TFTP Server Download Configuration This is the default main menu of the OAI Administration console This menu may change when the configuration procedure is completed depending on the OAI Gateway and the type of system See following page for the IP systems main menu Note that if the OAI Gateway is a MOG6xx model the TFTP Server Download Configuration option appears on the d...

Страница 18: ...4 2 IP Systems Main Menu One the configuration procedure is completed the IP System menu adds a Feature Programming option Additionally the OAI Line Configuration option is replaced by a Telephone Line Configuration option Part Number 72 0078 07 A doc Page 18 ...

Страница 19: ...res should be done after the Wireless Telephones have been configured in the NetLink Telephony Gateway Generally configuration follows these steps 1 Establish type of system through OAI Box Configuration option 2 Establish Network settings through Network Configuration option 3 Configure the Wireless Telephones through either OAI Line Configuration for NetLink Gateway systems or through Telephone ...

Страница 20: ...nge this option to Yes Note mogX00 is a model designation for the OAI Gateway TFTP Download Master enter the IP address of the TFTP server Maintenance Lock the system sets this option to Yes when the system needs to be reset Note that the administrator cannot change this option It is automatically set by the system after certain maintenance activities that require reset and will not return to No u...

Страница 21: ...t the factory and not user configurable IP Address Established in the initial serial connection and may be changed as needed The IP address of the NetLink OAI Gateway defined by your network administrator Enter the complete address including digits and periods DHCP should not be used with IP OAI Hostname change the default host name if desired This is the name of the gateway to which you are conne...

Страница 22: ... IP addresses When using Telnet it is also possible to access the OAI Gateway using its hostname instead of the IP address Logging and Log server Logging can be set to Syslog or NONE The log server is the IP address or hostname of the syslog server on the network The gateway will output syslog format diagnostic messages This is usually not needed SNTP server can be set to a hostname IP address or ...

Страница 23: ... System menu select OAI Line Configuration A screen similar to the following displays Enter the Hostname of the NetLink Telephony Gateway The OAI Gateway will fill in the hostname and port number based on the last entry Simply press Enter to accept the default port number and Hostname as you continue to the next line If the Telephony Gateway is active on the network the IP address field will be up...

Страница 24: ...the MAC address is printed on the sticker underneath the battery on the Wireless Telephone It can also be displayed on the Wireless Telephone by turning off the Wireless Telephone and then pressing and holding the Pwr power button The MAC address appears on the first line of the display 12 characters The MAC address must be manually entered by typing the entire address including digits and colons ...

Страница 25: ...s Esc to return to the NetLink OAI System menu 5 6 Searching for a Wireless Phone While in the Telephone Line Configuration or the Telephone Line Status screens a search hotkey is available To search any field 1 Select the field to use as the search key MAC address Name or Extension 2 Press S to display a search screen dialog box 3 Type an appropriate search string and then press Enter The success...

Страница 26: ... Feature Programming A screen similar to the following displays Use the arrow keys to select the function number to associate with OAI and type any label up to six characters What you type here will be displayed on the Wireless Telephone menu In the example screen above the FCN key sequence will display PhonBk on the Wireless Telephone function menu The OAI application in this case is a phone book...

Страница 27: ...AI and Telephony Gateways all have the same password To set or change the password select the Change Password option from the NetLink OAI System menu This option is on NetLink Telephony Gateway systems only It allows you to set the password established here on all NetLink Gateways in the system Using this option overrides any password already established on the NetLink Telephony Gateways The defau...

Страница 28: ...application is communicating correctly with the NetLink OAI Gateway It will be No when the application is not connected This will change dynamically Error Status The only OAI specific error is No ECP heartbeat which means the application failed to send a heartbeat to the Gateway Network Status Information about the connection to the Local Area Network LAN Software Versions lists the software versi...

Страница 29: ...od the length of time the statistics have been accumulating in the Pkts and Bytes columns This is either the system uptime or the time since a user pressed C Clear while viewing this display User Time Period the length of time in seconds statistics will accumulate in the Userpkts column before resetting to zero When troubleshooting a problem use this setting to isolate statistics for a given time ...

Страница 30: ...mitted Interrupts the number of times the Ethernet controller has signaled the microprocessor that it has received or sent a packet Collisions the number of times the Ethernet controller has attempted to send a packet but another device on the network transmitted at the same time corrupting the transmission Collision Drops the number of packets the Ethernet controller has discarded because there w...

Страница 31: ...p of 16 by using the arrow keys WT MAC the MAC address of the Wireless Telephone entered at configuration Name Extension these fields contain the data entered at configuration Phone No ChkIn indicates the Wireless Telephone is not currently using the OAI function ChkIn indicates the Wireless Telephone is currently communicating with the Gateway The functioning of the S Search hotkey is described u...

Страница 32: ...elp you determine if you are running the most recent version and will assist SpectraLink engineering and or customer support in troubleshooting software problems There are two separate methods of downloading new software one for the IP system and one for the NetLink Telephony Gateway system See the Software Maintenance section for information about upgrading or downloading your software From the S...

Страница 33: ...less Telephone registration and PBX programming and perform the usual voice and coverage tests when Wireless Telephone installation is complete If you added the NetLink OAI Gateway to an existing system place a call and test the features on each Wireless Telephone to be sure the system is working properly Test the application on each Wireless Telephone Consult your application provider for specifi...

Страница 34: ...e code used by the corresponding component The FTP File Transfer Protocol method of transfer is used In the NetLink OAI Gateway the flash file system has the following files File name Description config bin The OAI box configuraton fnctla bin The functional code oaiptlst bin The phone list configuration oaipttlsb bin The redundant phone list configuration The fnctla bin file is upgraded periodical...

Страница 35: ...nd password default is admin A login confirmation message will display followed by the FTP prompt 3 At the FTP prompt type binary A confirmation message will display 4 At the FTP prompt use the put command to transfer the functional code file to the client server or OAI Gateway It must be renamed before being loaded into the OAI Gateway The download file is named MOG700 bin Rename it fnctla bin Ex...

Страница 36: ...ftware for example downloading from a web site Obtain and load a TFTP server on a LAN connected system Consult your server vendor s documentation for information about TFTP Once the update is obtained from SpectraLink load it in a location that is accessible by the TFTP program To configure the host and start the download select the TFTP Server Download Configuration option from the NetLink OAI Sy...

Страница 37: ...A doc Page 37 10 Wireless Device Planning Worksheet Copy and complete this worksheet to track parameters for each NetLink Wireless Telephone OAI Port MAC Address User Name Dialing Ext IP Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 ...

Отзывы: