10.0 Check the front panel controls and indicators. Refer to Figure 2-4,
8144-DD Front Panel, for locations of these controls and indicators.
10.1
ALARMS and INDICATORS
The
Major
indicator is red if both clock sources have failed.
The
Minor
indicator is red if there is a failure of one clock
source. Front panel alarm indicators may be cleared with the
RESET
if the clock sources have been restored. The
ACO
clears remote fault indicators even though the alarm conditions
still exist.
10.2
The
READY
indicators are green if the corresponding clock
input is present and not in an AIS condition.
10.3
The
green
SELECTED
indicator switch corresponds to the input
currently selected.
10.4
AUTO/MAN
switch:
If revertive A priority has been selected on H16 - in the
AUTO
position, a ready A clock source has priority. Failure of the A
clock switches the unit to the B clock input. When the A input
returns, the unit will switch back to the A input.
If non-revertive switching has been selected on H16 - in the
AUTO position, selected input can be A or B. Unit stays on the
selected input until an alarm causes a switch to the other input.
In
the
MAN
position, clock selection is operator-controlled by
the A or B Select pushbuttons.
11.0 The Model 8144-DD is now operational.
Содержание 8144-DD
Страница 14: ...SECTION 2 INSTALLATION 2 0 INTRODUCTION 2 1 PREPARATION FOR USE 2 2 SWITCH AND HEADER SETTINGS ...
Страница 18: ...Section 2 Installation Page 2 4 Instruction Manual 8144 DD 075020 FIGURE 2 2 MODEL 8144 DD COMPONENT LAYOUT ...
Страница 33: ...SECTION 4 OPTIONS 4 1 DC POWER OPTIONS 52 AND 54 4 2 MOUNTING OPTIONS ...
Страница 37: ...SECTION 5 SERVICE INFORMATION 5 0 MAINTENANCE AND CALIBRATION 5 1 FUSE REQUIREMENTS ...