Section 1: General Information
Page 1-4
Instruction Manual 8144-DD/075020
ALARM INPUTS
The alarm inputs are configured to operate as RS-422/485 receivers as follows:
Line
Rate:
DC
Level:
Sensitivity ±200 mV, hysteresis 50 mV typical
Termination:
Balanced twisted pair
Impedance:
Terminated 120 ohms ±5%
Unterminated > 4K ohms
Alarm inputs can also be configured for contact closure input. A contact closure
between pins 1 and 3 on the alarm inputs alarms the A channel. A contact closure
between pins 4 and 6 alarms the B channel.
1.6.2 DS1
Outputs
The Model 8144-DD provides up to twelve clock outputs.
DS1 CLOCK OUTPUTS
The twelve DS1 clock outputs comply with ANSI T1.102-1987 as follows:
Line Rate:
1.544 Mb/s
Tolerance:
Same frequency as input
Level:
2.4 to 3.6V base-to-peak into 100 ohms ±5%
Termination:
Balanced twisted pair
Impedance:
100 ohms ±5%
Pulse Shape:
Per Figure 1 of ANSI T1.102-1987
1.6.3 Power
Requirements
Standard Option:
115/230 VAC ±15% 50/60 Hz, 15 watts
Option 52, 12 to 24 VDC:
±11.0 to 32.0 VDC, 12 watts
Option 54, 48 VDC:
±55.2 VDC ±20%, 12 watts
1.6.4
Mechanical and Environmental Specifications
Height:
2 rack units (3.50 inches)
Width:
EIA 19" rack
Depth:
10
inches
Weight:
6 lbs. maximum
Temperature: 0
to +50°C operating range
Humidity:
95% R. H. non-condensing
Содержание 8144-DD
Страница 14: ...SECTION 2 INSTALLATION 2 0 INTRODUCTION 2 1 PREPARATION FOR USE 2 2 SWITCH AND HEADER SETTINGS ...
Страница 18: ...Section 2 Installation Page 2 4 Instruction Manual 8144 DD 075020 FIGURE 2 2 MODEL 8144 DD COMPONENT LAYOUT ...
Страница 33: ...SECTION 4 OPTIONS 4 1 DC POWER OPTIONS 52 AND 54 4 2 MOUNTING OPTIONS ...
Страница 37: ...SECTION 5 SERVICE INFORMATION 5 0 MAINTENANCE AND CALIBRATION 5 1 FUSE REQUIREMENTS ...