6 / 0 5
V 2 0 0 - 1 8 - E 3 X B
S n a p - i n I / O M o d u l e
Analog I/O’s Power Supply
Nominal operating voltage
24VDC
Operating voltage
20.4 to 28.8VDC
Quiescent current
70mA@24VDC
Max. current consumption
130mA@24VDC
Galvanic isolation
Analog power supply to bus
Yes
Analog power supply to
analog inputs
Yes
Analog power supply to
analog outputs
Yes
Analog/ PT100/ TC Inputs
Number of inputs
4
Type of input
Set via appropriate wiring and jumper settings.
Analog Inputs Power Supply
Galvanic isolation
Analog/PT/TC inputs to bus
Yes
Analog/PT/TC inputs to
analog outputs
Yes
Analog /PT/TC inputs to
Analog /PT/TC inputs
No
Analog inputs
Input range
0-10V, 0-20mA , 4-20mA
Power supply
See Analog I/O’s Power Supply above
Conversion method
Succesive approximation
Resolution at 0-10V,
0-20mA
14-bit (16384 units). See Note 6.
Resolution at 4-20mA
3277 to 16384 (13107 units). See Note 6.
Conversion time
Synchronized to cycle time
Input impedance
>1M
ȍ
—voltage
121.5
ȍ
—current
Absolute maximum rating
±20V—voltage
±40mA—current
Full-scale error
±0.4%
Linearity error
±0.04%
Status indication
Yes. See Note 7.
Notes:
6.
12 or 14-bit resolution may be selected via software.
7.
The analog value can indicate faults as shown below:
Value Possible
Cause
16384 Input value deviates
slightly above
the input range
32767 -Input value deviates
greatly above
or
below
the input range
-Power supply disconnected
Spectra GmbH & Co. KG
[email protected]
Spectra (Schweiz) AG
[email protected]