EPSILON CLOCK MODEL EC22S
Spectracom Corporation
EPSILON CLOCK User’s Manual
5-12
4) Traps destination 1: Primary SNMP manager address where traps are sent. Clear field to
deactivate.
5) Traps destination 2: Secondary SNMP manager address where traps are sent.
6) Global Traps Enable: If "Yes", traps are sent according to individual enabling; if "No", no
trap are sent.
7) Global Traps Enable: If "Yes", traps are sent according to individual enabling; If "No", no
traps are sent.
8) Clock Fault:
a. Yes: Generates a trap when the EC22S goes on default (according to "Global
Status")
b. No: No trap generated.
9) GPS fault:
a. Yes: Generates a trap when the gps receiver fails or unlocks (according to "GPS
Lock")).
b. No: No trap generated.
10) External 1PPS Fault:
a. Yes: Generates a trap when the External 1PPS is lost (while enabled)
b. No: No trap generated.
11) Optional Reference source Fault:
a. Yes: Generates a trap when the Optional reference source is lost and this reference
is enabled.
b. No: No trap generated.
12) Internal oscillator Fault:
a. Yes: Generates a trap when the frequency driver goes on alarm (generally the OCXO
goes on default).
b. No: no trap generated.
13) Internal 1PPS Fault:
a. Yes: Generates a trap when the 1PPS driver goes on alarm.
b. No: No trap generated.
14) Phase Accuracy Fault:
a. Yes: Generates a trap when estimated phase of the output signal exceeds the phase
limit.
b. No: No trap generated
15) Frequency Accuracy Fault:
a. Yes: Generates a trap when estimated frequency of the output signal exceeds the
phase limit.
b. No: No trap generated
Содержание EC22S
Страница 4: ...extended coverage...
Страница 5: ...Spectracom Corporation 8194B 8195B 8197B...
Страница 6: ......
Страница 10: ...EPSILON CLOCK MODEL EC22S Spectracom Corporation EPSILON CLOCK User s Manual vi...
Страница 35: ...Spectracom Corporation EPSILON CLOCK MODEL EC22S EPSILON CLOCK User s Manual 5 3 5 2 3 Clock Status page...
Страница 56: ......
Страница 62: ......