14
Aquifer Operation continued...
Purifying Salt Water From a Container or Tank
If the system has been pickled or stored or contains cleaning compounds, use the
“
New
System Startup
”
procedure.
1.
Set up a system to supply feed water to the container.
2.
Set up the product tubing so that the product is being discarded and can be sampled.
3.
Place the feed hose into the tank or well and identify a suitable location for the brine dis-
charge hose.
4.
Start the feed pump and check for flow by inspecting the brine discharge or checking for
pressure on your pressure gauge. If there is no flow open the pressure relief valve on the
Clark Pump and bleed the air out of the feed pump (this may take a few minutes).
5.
Check the product water with your hand held salinity tester. When it is below 750 PPM,
you may divert it into your fresh water container.
Shutting Down
1.
Make about 3 gallons of water into a bucket. This water will be used to flush the salt wa-
ter out of the watermaker.
Use only unchlorinated water for flushing
2.
Install the intake service hose and place it in the bucket. Start the feed pump.
3.
Flush until container is empty, note the pressure will drop on the gauge indicating that
the membrane is flooded with fresh water. Stop the feed pump.
4.
Disconnect and stow the hoses connecting them together so water will not drip into the
case.
You may now leave the system unattended for up to five days without further attention.
We recommend operating the system for longer periods and effecting a fresh water flush
rather than running the machine every day and not flushing the system. Remember that you
need to run the system almost a half an hour to make the flushing water. You may notice
that the system output is higher while charging your batteries as the machine is voltage sen-
sitive.
For the Power Pack Solar units, the battery should be fully charged (if possible) after the watermaker
is shut down to extend battery life. Battery life is extended significantly when they are kept fully
charged. The solar controller will drain the battery over time if left connected so either disconnect
the fully charged battery or plug the charger into a 110v source for extended storage.
Содержание Aquifer AF-200-DC
Страница 2: ...2...
Страница 31: ...31...
Страница 37: ...37 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB10 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used...
Страница 39: ...39 Parts 1...
Страница 40: ...40 PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...