background image

CARE & MAINTENANCE

27

Protecting the Spectra Laser Level Kit

 

Your Spectra Laser Level is precision levelling equipment and should be treated as such. 

Always handle with care and transport within the carry case provided.

 

Always turn the laser level off  when transporting or moving around the job site.

 

Ensure the laser & accessories are clean and dry before storing in the case. 

 

If wet, dry well before storing and store the case and contents at room temperature. Failure 

to do so may void warranty.

 

NEVER store the Spectra Laser Level Kit in a van, car or an unheated location (workshop 

/ shed / garage / lockup etc.) overnight. The Spectra Laser Level Kit is designed to work in 

cold and wet conditions but it’s the storage of the product when not in use that is critical. 

Keeping it in a secure heated building increases the usable life of the product and reduces 

the possibility of theft.

 

When the laser level is not in use or is being stored long term, it is highly recommended to 

remove the batteries or battery pack from the base of the laser as well as the batteries in the 

remote control and detector.

 

Ensure the protective lighthouse glass is clean and free of dust and dirt at all times.

 

Only use the supplied charger with the laser. The charger is for indoor use only. If the 

charger becomes damaged, stop using immediately and purchase a replacement. 

Never use 

a generic charger with this laser.

 

Always check the accuracy of the laser level before precision levelling is attempted. Failure to 

do so may result in inaccurate levels. See page 

23

 for further details.

 

If the 

Laser Level

 has received a heavy impact or has been dropped, please ensure the 

calibration is checked. 

 

There are no user serviceable parts inside the 

Laser Level

. Warranty void if tampered. 

Содержание GL422N

Страница 1: ...r Levels Online Spectra Precision Laser Range REVISION 1 1 Handy Tips Advice 2021 Laser Levels Online Spectra LL100N Spectra HV101 Spectra LL300N Spectra LL300S Spectra HV302 Spectra HV302G Spectra GL...

Страница 2: ...day because we have always made communication and listening to our customers a top priority We also employ the best engineers and technical specialists we can nd to ensure that our reputation for inno...

Страница 3: ...pm indicating a level datum No other button needs to be pressed for the laser to self level When you have established the horizontal datum you can then use the mm scale on the rear of the measuring st...

Страница 4: ...ss is complete the laser will start spinning at 600rpm indicating a vertically level datum No other button needs to be pressed for the laser to self level 2 Turn the Detector onto it s side landscape...

Страница 5: ...etector onto it s side landscape mode and face towards the Laser The up and down arrows used for horizontal levelling will then become left and right arrows The Detector will accurately pinpoint the v...

Страница 6: ...ately and purchase a replacement Never use a generic charger with this laser The general procedure to adopt is to use the laser during the day charge up overnight You cannot damage the system by over...

Страница 7: ...use Important Do NOT allow battery to go completely at before recharging Rechargeable Battery Pack Removal Procedure Turn the laser over Twist the central battery latch through 90 degrees to remove t...

Страница 8: ...give around 30 hours of continuous use The GL422N battery pack will give around 35 hours of continuous use Important Do NOT allow battery to go completely at before recharging Rechargeable Battery Pac...

Страница 9: ...t polarity into the laser itself Although the Spectra LL300N LL300S HV302 HV302G and GL422N Lasers are intended to run using a rechargeable battery pack it is also possible to use 4 x type D Alkaline...

Страница 10: ...attery compartment and t 2 x 1 5v type D alkaline replacement batteries taking care to ensure correct polarity Type D alkaline batteries are readily available from all good hardware stores supermarket...

Страница 11: ...a feature not available on any Spectra laser level system It is compatible with the Spectra LL100N Spectra HV101 Spectra LL300N only However not all remote functions are available on all models of las...

Страница 12: ...door Groundworks run the HV101 at its maximum speed of 600rpm which gives the best working range when used with the supplied Laser Detector The default rotational mode is 600rpm when the laser self le...

Страница 13: ...ng at 600rpm The laser is now running in self levelling mode once more Up Down Left Right Arrows When the LL100N HV101 or LL300N is in manual mode Self levelling system has been turned o the Up Down L...

Страница 14: ...tum and then begin rotating at 600rpm The laser is now running in self levelling mode once more Setting Y Axis Slope This example sets a grade in the Y axis Press the ON OFF button once and the Laser...

Страница 15: ...ore convenient to use the laser in its Manual mode Next remove the bracket from your laser detector Switch the detector ON and lay it on its SIDE over a distant mark along one side of the concrete sla...

Страница 16: ...entially introduce an error or inaccuracy to the 90 degree squaring procedure Dot axis alignment Depending on your make model of laser level most have a light house cover over the prism with glass win...

Страница 17: ...per than 1 in 40 the liquid may run faster than the solids in a foul water pipe thus leaving the solids stranded which could then block the pipe Conversely if a gradient is not steep enough usually le...

Страница 18: ...d to gain access to a drainage system for un blocking cleaning rodding or inspection Land drainage systems excluded They can be manufactured in PVC masonry or pre cast concrete When setting appropriat...

Страница 19: ...0 278 1 27 3 704 1 67 1 492 1 135 0 740 1 370 0 270 1 28 3 572 1 68 1 470 1 140 0 714 1 380 0 264 1 29 3 448 1 69 1 450 1 145 0 690 1 390 0 256 1 30 3 334 1 70 1 428 1 150 0 666 1 400 0 250 1 31 3 226...

Страница 20: ...20 HOW TO SET SLOPES FALLS GRADES Working Example 2 when you do NOT know the grade to set Diagram 1 Diagram 2 Diagram 3 Use diagrams in conjunction with written example on page 21...

Страница 21: ...annel to join A to B Procedure First measure distance D Next attach the laser level on the surveying tripod switch it ON and allow it to auto self level The tripod height is unimportant Face keypad Y...

Страница 22: ...ls LL300S HV302 HV302G GL422N To make the next adjustment use the RC402N radio remote control if distance D is less than 100m or a colleague at the laser if D is more than 100m Hold the UP arrow butto...

Страница 23: ...o the right hand wall and mark the position of the laser beam on the wall Walk back to the laser and carefully twist the laser level round so the laser keypad now faces the left wall Be extremely care...

Страница 24: ...deviation can be appreciable even over small distances In some instances a double beam position can occur and the wrong level marked Our advice is to be aware of this and take appropriate care when se...

Страница 25: ...ses problems Its false economy Ensure that all users are aware of which batteries are tted so that in error a charger is not plugged into a laser level tted with standard batteries which could cause s...

Страница 26: ...nd ensure that the compartment is clean and that the battery terminals are not corroded Detector Not Detect ing The Laser Beam All Laser Levels Multiple Causes Check the batteries in the detector They...

Страница 27: ...ecure heated building increases the usable life of the product and reduces the possibility of theft When the laser level is not in use or is being stored long term it is highly recommended to remove t...

Страница 28: ...ester eld Derbyshire S41 9FG United Kingdom Freephone 08000 869 769 Free from UK mobiles and landlines www laser level co uk sales laser level co uk Put a Magnetic Detector Receiver on your machine an...