![Spectra Geospatial Focus 35 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/spectra-geospatial/focus-35/focus-35_user-manual_1343390076.webp)
4 Setup
To correct the horizontal position of the laser spot, insert the allen key into the horizontal adjustment
port and turn it as shown:
Check the alignment of the laser spot and the cross-hairs. Throughout the adjustment procedure, keep
the telescope pointing to the adjustment target. The adjusting screws are of a high tension because they
are self locking. The screws tighten automatically after you adjust them.
Refit the plugs in the adjustment holes. Make sure that the plugs are correctly fitted for proper sealing
against the cover.
CAUTION –
To keep out moisture and dust, make sure that the plugs are correctly fitted in the
adjustment ports.
FOCUS 35 Total Station User Guide |