![Speco O2VB1V Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/speco/o2vb1v/o2vb1v_user-manual_1342109026.webp)
22
Sub stream: The address format is
“rtsp://IP address: rtsp port/profile2?transportmode=mcast”.
Third stream: The address format is
“rtsp://IP address: rtsp port/profile3?transportmode=mcast”.
Audio: Having entered the main/sub stream in a media player(like VLC), the video and audio will play automatically.
If “Allow anonymous login…” is checked, there is no need to enter the username and password to view the video.
If “auto start” is enabled, the multicast received data should be added into a VLC player to play the video.
4.5.7
UPNP
If this function is enabled, the camera can be quickly accessed through the LAN.
Go to Network
UPnP. Enable UPNP and then enter UPnP name.
4.5.8
If you need to trigger Email when an alarm happens or IP address is changed, please set the Email here first.
Go to Network
Email.
Sender Address: sender’s e-mail address.
User name and password: sender’s user name and password.
Server Address: The SMTP IP address or host name.
Select the secure connection type at the “Secure Connection” pull-down list according to what’s required.
SMTP Port: The SMTP port.
Send Interval(S): The time interval of sending email. For example, if it is set to 60 seconds and multiple motion detection alarms
are triggered within 60 seconds, they will be considered as only one alarm event and only one email will be sent. If one motion
alarm event is triggered and then another motion detection alarm event is triggered after 60 seconds, two emails will be sent.
When different alarms are triggered at the same time, multiple emails will be sent separately.
Click the “Test” button to test the connection of the account.
Recipient Address: receiver’s e-mail address.