![Speck EQF 810 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/speck/eqf-810/eqf-810_reference-manual_1341732022.webp)
If it becomes necessary to change the mains voltage, there is a voltage
selector switch inside the EQF 810. The cover must be removed to gain
access to the selector switch.
Always remove the power cord from the power inlet (#23) before
changing the 115/230 voltage selector.
Take the cover off by removing (6) phillips screws on the sides of the
cover, and remove (5) phillips screws on the back of the cover. Do not
remove any other internal mounting screws.
Take the cover off and you will see a slide switch mounted on the green
circuit board as shown in Figure 4. Beside the switch (#26) are
markings in white letters: 115-------230.
If your mains voltage is 100VAC or 120VAC, set the voltage selector
switch to the “115” position.
If your mains voltage is 220VAC, 230VAC or 240VAC, set the voltage
selector switch to the “230” position.
Replace the cover and change the fuse according to the chart shown in
Figure 3, on Page 17.
It is recommended that you
remove the factory marking in
the small square box below the
serial number with a solvent
and re-mark the box so it
indicates the proper operating
voltage.
26
26. Mains Voltage
Selector Switch
Figure 4
Chapter 3
Operation Section