8
NOTE: Under certain conditions it is possible that
the current “drifts off” to the left or the right from
the middle due to water bouncing off the back wall.
In the event that it interferes with your swimming
action, turn the unit OFF for a few minutes and
restart.
Getting Started - continued
Before starting the pump for the first time (or after losing prime),
remove the red filler plug. Fill the pump body with water (approx.
2 gallons) until the water is level with the suction inlet. Replace
the red filler plug, hand tighten, making sure the o-ring is not
damaged. Due to the large amount of air that can be trapped in
the vertical portion of the suction line above the water level,
initial priming time may be longer than with regular pool filtration
pumps. It may take up to ten (10) minutes. This will not damage
the mechanical seal. If prime is not achieved in ten (10) minutes,
stop the pump, re-fill the pump body and restart.
Figure 2 - The Speck Model 21-80/33 GS (US Motor)
The BaduStream system comes with a 4 HP self-priming pump (Speck Model 21-80/33 GS) to specifically work with the
swimjet system. The Model 21-80/33 GS self-priming pump has the ability to remove air from the plumbing lines when
installed above the water level (up to 4 feet). During the initial startup, the pump must be filled with water. You should never
run the pump dry for extended periods of time.
Fill Plug
Priming Pump
4
Service and Maintenance
WARNING: Before each use, the GFCI located on the side of the control box must be tested.
Control Box - Testing the GFCI
1. Press the RESET button on the GFCI. The GREEN “power” LED
should be ON.
2. Press the TEST button: GREEN LED should turn OFF. RED LED
should start blinking. Circuit breaker should trip to OFF position.
3. If sensing module LEDs DO NOT change or circuit breaker
DOES NOT trip, DO NOT USE THIS DEVICE. Consult a qualified
electrician for assistance.
4. Press RESET button: RED LED should turn OFF and GREEN LED
should turn ON.
5. MANUALLY RESET circuit breaker to ON position to restore
circuit power.
Figure 3 - Control Box
Содержание BaduJet super-sport II
Страница 18: ......
Страница 19: ...Rev 03 17 ES Manual de Servicio y Funcionamiento BADU JET super sport II Sistema de Nado Contra Corriente...
Страница 36: ......