background image

Installation, Operating, 

and Service Manual

Badu

®

 EcoM3V

Variable Speed Pool Pump

Содержание Badu EcoM3V

Страница 1: ...Installation Operating and Service Manual Badu EcoM3V Variable Speed Pool Pump...

Страница 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Manufactured by Speck Pumps Jacksonville Florida USA 2012 All Rights Reserved This document is subject to chang...

Страница 3: ...Operation 12 Start Up Guide 12 Changing the Default Speed 13 Adjusting the Speed 14 5 Service and Maintenance 15 Routine Maintenance 15 Winterizing 16 6 Troubleshooting 16 Controller Malfunction Warn...

Страница 4: ...ion outlet cover is missing broken or loose The following guidelines provide information for pump installation that minimizes risk of injury to users of pools spas and hot tubs Entrapment Protection T...

Страница 5: ...ished edition of ANSI ASME A112 19 8 ANSI APSP 16 2011 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas Hot Tubs and Whirlpool Bathtub Applications Testing and Certification...

Страница 6: ...use with permanently installed pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a bu...

Страница 7: ...ed control panel provides manual speed controls for the pump There are three preset speed buttons that can be selected LOW MEDIUM and HIGH Controls and LEDs 1 LOW MED and HIGH buttons LED Press one of...

Страница 8: ...the vicinity of this pump DO NOT store pool chemicals near the pump 6 DO NOT remove any safety alert labels such as DANGER WARNING or CAUTION Keep safety labels in good condition and replace any missi...

Страница 9: ...hould always be followed The wiring of the motor should be done by a licensed electrician in accordance with local codes BONDING AND GROUNDING 1 The motor frame must be grounded to a reliable groundin...

Страница 10: ...onto the motor Carefully lift the top panel and turn it over to expose the inside terminal box See Figure 2 2 The terminal box is supplied with a 1 2 14 NPS threaded hole Use only liquid tight fitting...

Страница 11: ...system during the filling process This air will compress when the system is pressurized Should the system fail this trapped air can propel debris at a high speed and cause injury Every effort to remov...

Страница 12: ...lid and fill the basket with water before starting the pump 3 Prior to replacing the lid check for debris around the lid o ring seat Debris around the lid o ring seat will make it difficult to prime...

Страница 13: ...ng power to the unit Please follow all local state regulations regarding pool motor and timer speeds settings when choosing the default speed 1 Allow the pump to achieve prime if starting the system f...

Страница 14: ...ess the STOP button or wait 30 seconds without pressing any buttons NOTE If the power is shut off or the pump is stopped using the stop button upon powering up the pump will run a two 2 minute prime o...

Страница 15: ...o 10 seconds All LED light will be fully lit The LED s will blink to indicate the factory defaults were re established Adjusting the Speeds continued Routine Maintenance This pump requires little or n...

Страница 16: ...xpected Allowing the pump to freeze will cause severe damage and void the warranty There are two options when winterizing the pump Option 1 1 Drain all the water from the pump system equipment and pip...

Страница 17: ...rs during start up A Low Voltage During the initial start up 6 12 seconds delay there is a momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period...

Страница 18: ...r shaft noting the way it was originally installed CAUTION Do not damage the ceramic or carbon surfaces of the seal If the surfaces is damaged leaks will occur Figure 3 Removal and Replacement of the...

Страница 19: ...essing together 16 Make sure the diffuser and casing o rings are in place and free of debris Slide the motor flange into the casing 17 Tighten the eight screws using a cross pattern from side to side...

Страница 20: ...DRAIN 3 8 WITH GASKET CASING 2920889410 894 1 2 LEGO SPACER 2920889420 595 1 GASKET 1 4 x 7 16 x 1 2991000088 914 1 8 SCREW CASING HEX SLOT M7 x 48mm SS 2920141210 412 5 1 O RING DIFFUSER 90 x 5mm 29...

Страница 21: ...cturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and conditions 1 The pump and motor are warranted to be free from defects in material...

Страница 22: ...2999999995 Rev 05 2012...

Отзывы: