A-TMV

Thermostatic Mixing Valve

HELPFUL TOOLS & SUPPLIES:

TOOLS AND SUPPLIES

Thermometer

Measuring

Tape

Safety

Glasses

Pencil

Flat Tip

Screwdriver

Phillips

Screwdriver

Adjustable

Wrench

Phillips

Drive Bit

Drill

Drill Bit

Ø

5

/

16

Tile Drill Bit

Ø

5

/

16

IMPORTANT

• Compliance and conformity to local codes and
   ordinances is the responsibility of the installer.

• Valve should be accessible for testing, adjustment
   and maintenance in the installed position.

• Make sure that all water supply lines have been
   flushed and then completely turned off before
   beginning installation. Debris in supply lines can
   cause valves to malfunction.

• Ensure the mounting structure and mounting
   hardware can safely support the product in use.

• Do not over-tighten any connections or damage
   may occur.

• Be sure to read instructions thoroughly before
   beginning installation.

Be sure to wear eye protection.

SAFETY TIPS

Warranty information can be found at: 
www.speakman.com

WARRANTY

See section “Testing the Mixing Valve”.

MAINTENANCE

IMPORTANT

1

Determine desired mounting position of the 
A-TMV with Plastic Wall Bracket. Ensure 
mounting location is capable of supporting the 
product in use. Using a pencil, mark the hole 
location.

2

If mounting to drywall or tile, select appropriate 
5/16" drill bit and drill guide hole at marked 
location. Install the Plastic Wall Bracket into the 
drilled hole and press/tap into place until the 
bracket is flush to the wall surface. Secure the 
Plastic Wall Bracket to the wall with the proper 
Mounting Screw (included).

Ø

5

/

16

OR

OR

3

Ensure the A-TMV is vertical and the body rests 
on the top face of the Plastic Wall Bracket. 

4

Connect Supply Lines and Fixtures.

• Ensure incoming water supplies are turned OFF. 

• Install Inlet and Outlet connections to the valve.
   Wrench Tighten.

HOT

INLET

COLD

INLET

TEPID WATER

OUTLET

5

• Check for leaks by pressurizing the unit SLOWLY.

• Check the temperature and adjust if necessary.

HOT

INLET

COLD

INLET

TEPID WATER

OUTLET

CAUTION

When maintaining and 
adjusting the Mixing Valve, all 
fixtures should be isolated from 
use. Speakman recommends 
that appropriate personnel 
shall work safely at all times.

 

 

SETTING THE MIXING VALVE

Should the Valve require adjustment, or an 
application require a different set temperature, 
proceed as follows:

Adjust Temperature with Water Running

• Check the temperature with a stick thermometer.

• Contact proper medical and safety authorities
   to determine the correct water temperature for
   the specific application.

• Remove the Plastic Cap (White) from the Valve
   using a flat tip screwdriver.

REMOVE THE CAP WITH

FLAT TIP SCREWDRIVER

FROM THE NOTCH

ON THE CAP

 

 

SETTING THE MIXING VALVE

• Create a draw on the Mixing Valve by opening
   the faucet.

• Loosen, but do not remove the Locking Nut 

(2)

   using adjustable wrench. Invert Plastic Cap and
   align triangular recess in cap to the Adjuster
   Screw 

(1)

.

• Set the outlet temperature by turning the Adjuster
   Screw

 

clockwise to reduce temperature,

   counterclockwise to increase temperature.
   Use a stick Thermometer to check the outlet
   temperature.

• Tighten the Locking Nut to avoid inadvertent
   adjustment of outlet temperature.

WARMER

COLDER

Содержание EYESAVER SEF-18100

Страница 1: ...ace Hoses and Sensor Wires carefully one at a time through hole in mounting surface Lower Faucet Spout into position NOTE If installing with an optional deck plate please place hoses and wires through...

Страница 2: ...ntil the battery door is fully seated and locks into position 2 13 Make TEPID WATER connection to the inlet of the Eyewash supply A Speakman STW Series Thermostatic Mixing Valve is recommended not inc...

Страница 3: ...connections Make sure all electrical connections are fully inserted 2 If the Faucet does not operate replace the existing Solenoid Assembly with one you know to be functioning If the Faucet activates...

Страница 4: ...NG PRESSURE FLOW RATE PLUME DISTANCE A psi bar gpm L min in cm 30 2 07 1 76 6 7 1 1 5 29 21 40 2 76 2 03 7 7 1 3 33 02 50 3 45 2 1 8 8 3 1 4 35 56 60 4 1 4 2 1 7 9 1 3 33 02 70 4 83 2 1 7 9 1 3 5 34 2...

Страница 5: ...e appropriate hole in the counter top one at a time Align the valve assembly so the Rubber Access Plug 1 is facing the rear and install Valve Assembly through mounting hole 3 From below reinstall the...

Страница 6: ...N INCHES MILLIMETERS UNLESS OTHERWISE SPECIFIED DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE 2 MIN TO LEDGE 51mm 2 MIN TO WALL 51mm LAVATORY ROUGH IN 29mm 1 1 8 MIN NOTES COMPLIANCE CONNECTIONS ASME A1...

Страница 7: ...until the bracket is flush to the wall surface Secure the Plastic Wall Bracket to the wall with the proper Mounting Screw included 5 16 OR OR 3 Ensure the A TMV is vertical and the body rests on the...

Страница 8: ...e Element s body Note Gallon per minute ratings may vary depending upon incoming water temperatures and pressures Hot and cold water inlet pressures must be equal Provisions shall be made to thermally...

Отзывы: