8
After securing the Bracket to the mounting surface, align and slide Solenoid Assembly over Mounting Bracket.
9
Make electrical connections from the Sensor Eye to the Solenoid Assembly. Connect the Blue Male Ended Wire
to the Blue Female Connection. Connect the Green Male Ended Wire to the Green Female Connection. To
further aid proper alignment, there are white alignment lines on the connector ends. These alignment lines
should face forward when properly installed.
GREEN
BLUE
10
FOR BATTERY MODELS (SEF-18100 SERIES)
Access the interior Battery Enclosure by pressing down on the tab to release the tray holding the batteries (1). Pull out
Battery Tray (2). Insert or replace the batteries with six (6) new standard 1.5v AA batteries. Ensure the position of the
new batteries are aligned to the plus (+) and minus (-) symbols within the battery holder.
11
FOR A/C MODELS (SEF-18200 SERIES)
Verify that no batteries are present within the battery enclosure (1). Connect the A/C Adapter to the BLACK connector
on the Solenoid Body (2). Plug the A/C Adapter into the wall outlet. The A/C light (3) should illuminate.
12
Reinstall the Battery Tray (1). Make sure to press
the indicated location until the battery door is
fully seated and locks into position (2).
13
Make
TEPID WATER
connection to the inlet of the Eyewash supply. A Speakman
STW Series
Thermostatic Mixing Valve is recommended (not included). Make
WATER
connection to the inlet of the Solenoid. A Speakman
A-TMV
Thermostatic Mixing Valve is recommended (not included). Inlet supplies are not included. Wrench tighten
connections.
EYEWASH
TEPID
WATER SUPPLY
IMPORTANT
If shut off valves are
installed in the supply
line of the eyewash,
provisions shall be
made to prevent
unauthorized shut off.
IMPORTANT
Flush Tepid Water Supply
Lines into a Bucket for 1
Minute prior to making
connection.
FAUCET
TEPID
WATER SUPPLY
IMPORTANT
Dry Connections
Only! Do not use any
sealant on these
connections
14
After the assembly is complete, turn the Faucet and Eyewash water
supplies on. Activate Sensor and allow Faucet to run for 1 minute to
flush out any debris. Check all connections for leaks.
15
Install Aerator (1) into the Faucet Outlet. Secure with included Aerator
Wrench.
IMPORTANT
If installing optional
Outlets for either the
Eyewash or Faucet,
please do so at this
time.
16
Activate Faucet and test for proper operation.
NOTE: Before
testing, you must remove tape from Eyewash Dust Cap.
Lift
Eyewash Handle to activate Eyewash and test for proper operation.
See “EYEWASH FLOW DATA” chart
. Check all connections for leaks.