5“
2.6 COMBUSTION AIR
When mounting the air system ensure that the air control system provides fresh air from the outside. In order for
the air system to function, you have to ensure in the structure that no vacuum occurs in the housing. If convection
grates are installed, be sure not to block them. Air system (accessory) is connected to the bottom of the stove.
600-700 Backside air intake
2.6.1 CONNECTION DIRECTLY TO THE UNIT
To connect the separate combustion air directly to the unit you need to have the right separate combustion air
connector Ø 5”. Fix the connector directly to the unit. It can be oriented to the left side, right side or to the back.
Grills
The combustion air ducts will be protected at the outside by a grill. The free passage section of those grills is
at least equivalent to the section of the air inlet. Please note that the infiltration of water and the effect of the
wind can damage the system.