- 51 -
Fig. 5f
Varia A-FDh
H
2
O
- 52 -
Possible variant for incorporating the Varia A-FDh H
2
O into a heating
system (Fig. 5f).
A ¾”
feed
B ¾”
return
C
temperature sensor for the ½” overheat discharge valve
D
temperature sensor for the ½” overheat discharge valve
E
Thermal safety heat exchanger ½” ‘discharge’
F
Thermal safety heat exchanger ½” ‘feed’
G bleed
valve
3
/
8
”
H safety
valve
I bleed
valve
3
/
8
”
J
pump thermostat switch (e.g. JUMO, heatTHERM)
K heating
system
connection
L load
unit
M return
N
load unit fittings (e.g. Thermoventiler AB; type Laddomat 21)
O circulating
pump
P
filling and drain fittings
Q expansion
tank
R discharge
S
safety fittings for the overheat discharge valve (e.g. SYR 3065)
T Non-return
valve
Please note: Figures
2a – 2f
show options for incorporating an H
2
O
fireplace insert into existing heating systems. However, these are no
substitute for detailed planning of the installation by a specialist company.
Содержание Mini Z1 H2O
Страница 5: ...9 Mini Z1 H2O Fig 1a 10 Mini Z1 H2O XL Fig 1b...
Страница 6: ...11 Mini Z1h H2O XL Fig 1c 12 Varia 1V H2O Fig 1d...
Страница 7: ...13 Varia 1Vh H2O Fig 1e 14 Varia 1V H2O XL Fig 1f...
Страница 8: ...15 Varia 1Vh H2O XL Fig 1g 16 Varia 1V H2O XXL Fig 1h...
Страница 9: ...17 Varia 1Vh H2O XXL Fig 1i 18 Varia 2Lh 2Rh H2O Fig 1j...