background image

52

7.8 CARE OF PLATED PARTS 

If the appliance is equipped with plated parts, you must clean fingerprints 
or other marks from the plated surfaces before operating the appliance 
for the first time. Use a glass cleaner or vinegar and towel to clean. If 
not cleaned properly before operating for the first time, the marks can 
cause permanent blemishes on the plating. After the plating is cured, the 
fingerprints and oils will not affect the finish and little maintenance is 
required, just wipe clean as needed. Prolonged high temperature burning 
with the door ajar may cause discolouration on plated parts.

NOTE: The protective wrap on plated parts is best removed when the 
assembly is at room temperature but this can be improved if the assembly 
is warmed, using a hair dryer or similar heat source.

8. REPLACEMENTS

Contact your dealer or the factory for questions concerning prices and 
policies on replacement parts. Normally all parts can be ordered through 
your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT 
PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO 
HONOUR THE CLAIM. When ordering replacement parts always give the 
following information:

•  Model & Serial Number of appliance
•  Installation date of appliance
•  Part number
•  Description of part
•  Finish

*  IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER 

INFORMATION, CONTACT YOUR AUTHORIZED DEALER.

WARNING

FAILURE TO POSITION THE PARTS IN ACCORDANCE 

WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS 
SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY 

RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY.

For chamotte replacement see chapter 5.1

Содержание M 700 INSERT

Страница 1: ...600 ZERO CLEARANCE FIREPLACE M 700 ZERO CLEARANCE FIREPLACE Keep this insruction for future use Spartherm Feuerungstechnik GmbH Maschweg 38 D 49324 Melle Phone 49 0 5422 94 41 0 Fax 49 0 5422 9441 14...

Страница 2: ...ESCRIPTION SPARTHERM S600 M700 ZERO CLEARANCE FIREPLACE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL YOUR S600 M700 ZERO CLEARANCE FIREPLACE PLEASE READ THE MANUAL FOR OPERATING INSTRUCTIONS AND...

Страница 3: ...m diameter pipe Failure to provide this may starve other fuel burning appliances from an adequate air supply Make sure not to create negative pressure in the installation room e g by means of an exhau...

Страница 4: ...moke Safe Wood Burning Practices When using your wood burning appliance follow these guidelines for safe operation Keep flammable items like curtains furniture newspapers and books away from your appl...

Страница 5: ...24 MINIMUM CLEARANCES TO COMBUSTIBLES 25 PLACEMENT 0F S600 INSTALLATION 27 PLACEMENT OF M700 INSTALLATION 28 FLANGES AND ANCHOR PLATE 27 INSTALLATIONS HEARTH EXTENSIONS 29 DISTANCE TO COMBUSTIBLE MAN...

Страница 6: ...OR CHIMNEY FIRE 50 CHIMNEY CLEANING 51 GLASS REPLACEMENT 51 CARE OF GLASS 52 CLEANING THE GLASS CERAMIC SHEET 52 CARE OF PLATED PARTS 53 REPLACEMENTS 53 EXPLODED VIEW 54 TROUBLESHOOTING 56 GENERAL WA...

Страница 7: ...ate this wood heater in a manner inconsistent with operating instructions in this manual This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal re...

Страница 8: ...8 12 9 inches 25 33 cm 1 8 kg hr 2 1 kg hr Intermittent operation Flue gas mass flow grams per second grams per second Flue gas temperature C F C F Single wall connector stove pipe Canada 6 150mm USA...

Страница 9: ...essary WARNING THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED Do not operat...

Страница 10: ...to be installed on the appliance Keep the packaging material out of reach of children and dispose of the material in a safe manner As with all plastic bags these are not toys and should be kept away f...

Страница 11: ...Ne connectez pas ce po le un conduit de chemin e utilis par un autre appareil N utilisez pas de grille et ne faites pas monter le feu Etablissez le feu de bois directement dans l tre L installation d...

Страница 12: ...ce po le un conduit de chemin e utilis par un autre appareil N utilisez pas de grille et ne faites pas monter le feu Etablissez le feu de bois directement dans l tre L installation doit tre faite excl...

Страница 13: ...NSIONS Example shown S 600 S 600 fireplace A 18 7 9 477mm B 25 5 9 649mm C 23 1 3 592mm D 6 152mm E 17 1 3 441mm F 24 4 5 630mm Allgemeintoleranzen nach DIN 7168 mittel A B D C back cumbustion air con...

Страница 14: ...25 1 3 643mm D 6 152mm E 18 1 2 471mm F 28 5 6 732mm u0 15 u5 u0 3 u10 u0 6 u20 u0 9 u30 u1 8 u60 Abma e mm auf 100 mm 400 120 400 50 120 10 50 10 Abma e Winkelminuten Nennma des k rzeren Schenkels Al...

Страница 15: ...7 M 700 FIREPLACE 1 58 ft3 13 129 BTU h 29 452 BTU h 66 77 USA 7 x2 only CANADA 7 x1 only 298lbs 135kg 2 DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE THIS APPLIANCE AND TH...

Страница 16: ...ossible to enable the exhaust products to easily flow through it Chimney vent systems that are too short or too long refer to point 4 3 chimney installation can also have an adverse affect on the flow...

Страница 17: ...ide In order for the air system to function you have to ensure in the structure that no vacuum occurs in the housing If convection grates are installed be sure not to block them Air system accessory i...

Страница 18: ...to the back Fresh air ducts The ducts providing the outside combustion air should be as short as possible to prevent pressure loss and to prevent making the house cold Grills The combustion air ducts...

Страница 19: ...outside wall as possible The air duct should be insulated and the distance from the fireplace to the outside should be as short as possible For 5 air duct please refer to the maximum lengths and elbow...

Страница 20: ...PRECAUTIONS WILL REDUCE THE POSSIBILITY OF APPLIANCE SMOK ING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW OR ANY OTHER OBSTACLES IT MUST BE UNRESTRICT...

Страница 21: ...teilweise werden gem 2 Absatz Ziffer 7 96 ff und 106 ff Urhebergesetz sowie u U nach 1 3 4 18 und 19 UWG zivil und strafrechtlich verfolgt Bez glich Rechtsanspr che u d Benutzung gelten unsere allgeme...

Страница 22: ...y around the stove protect the stove surface with an acid proof cover Fresh Air Inlet Unless there is deemed to be insufficient residual air into the room via doorways windos and the like a dedicated...

Страница 23: ...BUSTIBLE MATERIALS Minimum hearth requirement Cassette Insert 600 Make sure there is enough space for the wood heater If the fireplace is fitted with a frame that s conceals the contours of the recess...

Страница 24: ...s of the recess an additional tolerance of 1 1 2 ca be set when the recess is made The wood heater must be able to expand freely The brickwork or decorative materials must not enter into contact with...

Страница 25: ...nt of the stove made of non combustible material is required In front of the unit the hearth exten sion must extend 6 on each side Also there must an hearth extension under the unit which extend 2 on...

Страница 26: ...en material A If the R value Thermal resistance is given no conversion is needed Configuration SIDE WALL TO UNIT SIDE WALL TO PIPE BACK WALL TO UNIT BACK WALL TO PIPE CEILING OR ALCOVE TO BOTTOM OF UN...

Страница 27: ...27 4 2 DISTANCE COMBUSTIBLE MANTLE MANTLE MINIMUM CLEARANCES For mantle that is 8 deep 7 1 4 Min 9 25 7 1 4...

Страница 28: ...9 228 6 mm Clearance to Combustible Wall Member Using a 8 203 2 mm inside diameter listed factory built Solid Pak chimney section with insulation of 1 25 4 mm or more build a wall pass through with a...

Страница 29: ...l surfaces on all sides Make sure fasteners used to secure the metal chimney connector do not penetrate chimney flue liner Method D 2 50 8 mm Clearance to Combustible Wall Member Start with a solid pa...

Страница 30: ...id the noise created when the fireplace expands This can be achieved by having the chimney supported by the supports The maximum chimney length that should be supported by the fireplace is 9 ft 2 75 m...

Страница 31: ...eiling floor separation through which the chimney will pass At the attic level install an attic radiation shield from above 3 Follow the chimney s manufacturers instructions and place the first chimne...

Страница 32: ...iant shield attic radiation shield flashing storm collar rain cap chimney section basement 1st floor attic elbow elbow wall radiation shield radiation shield attic radiation shield flashing storm coll...

Страница 33: ...y section insulated wall radiation shield elbow offset support wall band rain cap flashing storm collar basement 1st floor attic attic 1st floor basement chimney wall band offset support fireplace ins...

Страница 34: ...roots 2 ft 3 ft min 10 ft to nearest roofline less than 10 ft 2 ft 3 ft min pitched roof 3 ft min 3 ft min 2ft min less than 10 ft 10 ft or more wall or parapet flat roof windward leeward location NO...

Страница 35: ...over cut a six inch 6 3 4 171mm hole to lie directly below the fireplace flue opening Allow two inches of material for a flange on all sides and cut to these measurements Bend down the flanges If you...

Страница 36: ...installation instructions above If a continuous liner is not installed a direct flue connection must be made The direct flue connection requires a non combustible connector that extends from the modul...

Страница 37: ...N Circulation of convection air The convection air enters into the fireplace via the inlet at the bottom of the fireplace The hot air for convection comes out of the fireplace via the front outlet and...

Страница 38: ...ALLATION WARNING OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERATURES THAT COULD DAMAGE THE APPLIANCE CHIM NEY AND THE SURROUNDING ENCLOSURE NOTE DO NOT OPERATE IF BAFFL...

Страница 39: ...L INSTALLATION WARNING BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE DO NOT STRIKE OR SLAM DOOR NEVER REMOVE THE DOOR WHEN THE...

Страница 40: ...40...

Страница 41: ...the smell To start a brisk fire is required Place loosely crumpled paper on the floor of the appliance and cover with dry kindling Light the paper and leave the door slightly ajar one inch until all k...

Страница 42: ...this Without an appliance thermometer you are working blindly and have no idea of how the appliance is operating An appliance thermometer offers a guide to performance Can t get the fire going Use mor...

Страница 43: ...volume of combustion air and secondary air B Controlled burning Control lever approx 20 mm further than the closed air supply position This ensures that the fire does not receive too much air and the...

Страница 44: ...44 DOOR ASSEMBLY SPARE PARTS ROBAX 4MM CERAMIC GLASS USE ONLY AS PER MANUFACTURERS STANDARD AND SPARE PARTS 7 600 GLASS REPLACEMENT PART NUMBER SP 898 700 GLASS REPLACEMENT PART NUMBER SP 899...

Страница 45: ...f position For maximum efficiency when the appliance is throughly hot load it fully to the line of air inlet nozzles at the backside of the firebox or if not present to 50 of the fireboxes backside he...

Страница 46: ...ax binders etc Never burn more than two manufactured firelogs at a time Do s Dont s Build a hot fire Take ash out immediately Let it accumulate to a depth of at least one inch A good ash layer provide...

Страница 47: ...kitchen bathroom WC etc This will avoid low pressure building up in the installation room that can affect the extraction of flue gasses from the fireplace Check the combus tion air supply if required...

Страница 48: ...or for creosote and soot buildup weekly until a safe frequency for cleaning is established If accumulation is excessive disconnect the appliance and clean both the chimney and the appliance You may wa...

Страница 49: ...ocessed wood coal charcoal coloured paper or cardboard 7 1 ASH REMOVAL PROCEDURES WARNING IMPROPER DISPOSAL OF ASHES RESULTS IN FIRES DO NOT DISCARD ASHES IN CARDBOARD BOXES DUMP IN BACK YARDS OR STOR...

Страница 50: ...g a solid fuel appliance chimney in a few days if slow smoldering fires are burned and the chimney is cold NOTE Appliances burned consistently without hot fires may result in significant creosote accu...

Страница 51: ...rong but do not let burning fuel rest or fall against it and always close the door gently NEVER FORCE IT SHUT If the glass should ever crack or break while the fire is burning do not open the door unt...

Страница 52: ...but this can be improved if the assembly is warmed using a hair dryer or similar heat source 8 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacem...

Страница 53: ...1004 voll in Anspruch genommen Unbefugte Vervielf ltigungen tungen und Wiedergaben ganz oder teilweise werden gem 2 Absatz Ziffer 7 96 ff und 106 ff Urhebergesetz sowie u U nach 1 3 4 18 und 19 UWG z...

Страница 54: ...losed too far Open air control more Burn hotter smaller fires Use well seasoned wood 10 GENERAL WARRANTY TERMS AND CONDITIONS 10 1 GENERAL INFORMATION This quality manufactured product is state of the...

Страница 55: ...erload the elevating mechanism If the installation instructions are not correctly followed resulting in overheating of the pulleys and bearings the seals Reduced sealing due to thermal stress and hard...

Страница 56: ...56 10 6 FOR YOUR INFORMATION...

Страница 57: ...57 10 6 FOR YOUR INFORMATION...

Страница 58: ...58 10 6 FOR YOUR INFORMATION...

Страница 59: ...59 Appliance Service History This heater must be serviced annually depending on usage Date Dealer Name Service Technician Name Service Performed Special Concerns 11 SERVICE HISTORY...

Страница 60: ...ERM A1 SP US CA 05 2019 THE GLOBAL BRAND FOR YOUR LIVING ROOM Your specialist dealer Spartherm Feuerungstechnik GmbH Maschweg 38 D 49324 Melle Phone 49 0 5422 94 41 0 Fax 49 0 5422 9441 14 www sparthe...

Отзывы: