background image

3

TABLE OF CONTENTS

INTRODUCTION AND UNIT DESCRIPTION  

2

SAFETY INFORMATION 

2

SAFE WOOD-BURNING PRACTICES 

2

TABLE OF CONTENTS 

3

SPECIFICATIONS Cassette Insert 600/700 

4  

INSTALLATION  OVERVIEW 

4   

INTRODUCTION 5 

EXAMPLES OF IDENTIFICATION PLATES 

6  

DIMENSIONS 600 

7

DIMENSIONS 700 

7

SPECIFICATION 8

GENERAL INSTRUCTIONS 

GENERAL INFORMATION 

8

COMBUSTION AIR 

9

CONNECTION DIRECTLY TO THE UNIT 

9

CLOSURE VALVE 

10

INSTALLATION PLANNING 

10

MINIMUM CLEARANCES TO COMBUSTIBLES 

10

PLACEMENT 11

INSTALLATION 11

DISTANCE TO COMBUSTIBLE MANTLE 

12

CHIMNEY LINER INSTALLATION 

12

LISTED CHIMNEYS 

12

EXAMPLES OF TYPICAL INSTALLATIONS 

13

MASONRY 14

CONVECTION 15

FINISHING –BRICKS AND BAFFLE PLATE 

15

DOOR REMOVAL/INSTALLATION 

17

OPERATION 18

FIRE EXTINGUISHERS/SMOKE DETECTORS 

20

FUEL  

20

LIGHTING A FIRE 

20

FLASH FIRE 

21

EXTENDED FIRE 

21

SMOKING 21

MAINTENANCE 21

ASH REMOVAL PROCEDURES 

22

CREOSOTE FORMATION AND REMOVAL 

22

RUNAWAY OR CHIMNEY FIRE 

22

CHIMNEY CLEANING 

22

GLASS REPLACEMENT 

22

CARE OF GLASS 

22

CLEANING THE GLASS CERAMIC SHEET 

23

CARE OF PLATED PARTS 

23

REPLACEMENTS 23

EXPLODED VIEW 

24

TROUBLESHOOTING 24

GENERAL WARRANTY TERMS AND CONDITIONS  24

REQUIREMENT OF EFFECTIVENESS FOR 
THE WARRANTY 

24

WARRANTY EXCLUSIONS 

25

NOTE 46

FOR YOUR INFORMATION 

26

SERVICE HISTORY 

27

U.S. ENVIRONMENTAL PROTECTION AGENCY Certified 
to comply with 2020 particulate emission standards 
using cordwood 600 insert 1.67 g/hr and 700 insert 
1.14 g/hr, Method 28R

This insert needs periodic inspection and repair for 
proper operation. It is against federal regulations 
to operate this insert in a manner inconsistent with 
operating instructions in this manual.

This insert has a manufacturer-set minimum low burn 
rate that must not be altered. It is against federal reg-
ulations to alter this setting or otherwise operate this 
wood heater in a manner inconsistent with operating 
instructions in this manual.

Содержание Insert-600

Страница 1: ...refer to it Spartherm Feuerungstechnik GmbH Maschweg 38 49324 Melle Phone 49 5422 94 41 0 Fax 49 5422 9441 14 www spartherm com The Spartherm wood insert have been tested and certified by CSA based on...

Страница 2: ...raise the fire At least 14 square inches 90 3 square centime ters of outside air must be admitted to the room or directly to the unit through a 5 127mm diameter pipe Failure to provide this may starv...

Страница 3: ...NCE 21 ASH REMOVAL PROCEDURES 22 CREOSOTE FORMATION AND REMOVAL 22 RUNAWAY OR CHIMNEY FIRE 22 CHIMNEY CLEANING 22 GLASS REPLACEMENT 22 CARE OF GLASS 22 CLEANING THE GLASS CERAMIC SHEET 23 CARE OF PLAT...

Страница 4: ...amount of wood when fueling lbs kg wood 2 3 logs of wood of app 18 21 46 53cm 1 8 kg hr 2 1 kg hr Intermittent operation Single wall connector stove pipe 6 153mm 7 178 5mm Chimney pipe class A UL 103...

Страница 5: ...to protect infants toddlers from touching hot surfaces Even after the appliance is out the glass and or screen will remain hot for an extended period of time Check with your local hearth specialty dea...

Страница 6: ...da 18 457mm from unit to front of floor protector Safety Information Informations Sur La S curit Listed by Manufactured by Spartherm Feuerungstechnik GmbH Maschweg 38 D 49324 Melle Germany info sparth...

Страница 7: ...6 1 8 410mm B 22 5 16 566mm C 21 1 2 544mm D 23 582mm E 6 Example shown 600 Example shown 700 AVAILABLE FRAME FINISHES 60 MM 2 3 8 80 MM 3 1 8 100 MM 3 15 16 Insert 700 A 17 5 16 440mm B 26 1 4 666mm...

Страница 8: ...t systems that are too short or too long refer to point 4 3 chimney installation can also have an adverse affect on the flow of exhaust through it The wood burning appliance and chimney vent system al...

Страница 9: ...r directly to the unit you need to have the right separate combustion air connector 5 Fix the connector directly to the unit It can be oriented to the left side right side or to the back Grills The co...

Страница 10: ...ockage or other signs of deterioration If necessary have any repair work done by a qualified professional before installing the insert Do NOT remove bricks or mortar from the wood insert In case of an...

Страница 11: ...m bustible item such as drying clothes newspapers firewood etc Failure to meet the required clearances can endanger property and personal safety 3 1 2 PLACEMENT Make sure there is enough space for the...

Страница 12: ...with the following brands of chimney liner measuring 6 and 7 152 and 178mm in diameter 4 5 1 LISTED CHIMNEYS This appliance must be installed with a listed 6 and 7 chimney liner system approved under...

Страница 13: ...fireplace The masonry fireplace is to be con structed in accordance to N F P A 211 Latest Edition Standards of Chimney Fireplaces Vents and Solid Fu el Burning Appliances and Equipment or applicable...

Страница 14: ...rst Fasten this flue cover in position as high as possible with two masonry screws per side through the flanges into the wood insert I n Canada Install only flexible or solid chimney liner from the to...

Страница 15: ...convection air enters into the fireplace via the inlet at the bottom of the fireplace The hot air for convection comes out of the fireplace via the front outlet Air flow 5 FINISHING 5 1 BRICKS AND BA...

Страница 16: ...rice list 4 price list Attention Surcharge according to price list when ordering in eboris 1300 block Masonry Insert 700 fil l 0 l 7462 l l 017405 z l O1746l l 1017404 article designation base brick f...

Страница 17: ...L INSTALLATION WARNING BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE DO NOT STRIKE OR SLAM DOOR NEVER REMOVE THE DOOR WHEN THE...

Страница 18: ...in an unsatisfactory burn Remember it is more efficient to burn medium sized wood briskly and refuel frequently than to load the appliance with large logs that result in a smouldering inefficient fir...

Страница 19: ...not used there is a risk of BURNS A Air supply open when lighting the fire or adding new wood The control lever is pushed completely to the right The firebox will now receive the maximum volume of co...

Страница 20: ...d has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of a likelihood that the wood will roll onto the glass Manufactured firelog...

Страница 21: ...n Volume of wood to add per hour 11 When the wood has been completely burnt and only embers are remaining from the initial wood added to the fire new wood can now be added as required hard wood is ide...

Страница 22: ...uation and a place outside for everyone to meet Prepare to evacuate to ensure everyone s safety Close air control on appliance Call local fire department Have a fire extin guisher handy Contact local...

Страница 23: ...or vinegar and towel to clean If not cleaned properly before operating for the first time the marks can cause permanent blemishes on the plating After the plating is cured the fingerprints and oils wi...

Страница 24: ...aft Add more pipe Let air stabilize before opening door Ensure baffles are positioned correctly Negative pressure Open a window near the appliance Appliance emits odour Paint curing See GENERAL INSTRU...

Страница 25: ...or overload the elevating mechanism If the installation instructions are not correctly fol lowed resulting in overheating of the pulleys and bearings the seals Reduced sealing due to thermal stress a...

Страница 26: ...26 10 6 FOR YOUR INFORMATION...

Страница 27: ...27 11 SERVICE HISTORY Appliance Service History This heater must be serviced annually depending on usage Date Dealer Name Service Technician Name Service Performed Special Concerns...

Страница 28: ...ARTHERM A1 SP US CA 04 2021 THE GLOBAL BRAND FOR YOUR LIVING ROOM Your specialist dealer Spartherm Feuerungstechnik GmbH Maschweg 38 49324 Melle Phone 49 5422 94 41 0 Fax 49 5422 9441 14 www spartherm...

Отзывы: