![Spartherm ebios fire Chelsea Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/spartherm/ebios-fire-chelsea/ebios-fire-chelsea_instructions-for-assembly-and-use_1340258006.webp)
GB
6
2.3 INSTALLATION SITE
During set-up and installation of the ebios-fire, ensure that the equipment
is not located immediately beside major heat sources (radiators, chimney
ovens etc.) or in installation spaces with high temperature loads (e.g. sau-
nas). Outside heating of the ethanol fireplace when it is not in operation can
cause the fuel in the tank to be forced out through the burner channel and
then to collect in the safety tray. In such cases, before lighting the ebios-
fire, remove the burner and empty the safety tray.
Your ebios-fire must not be set up:
• In stairways except in residential buildings with two or fewer flats.
• In hallways with general access.
• In garages
• Outside
• In rooms containing readily flammable or explosive substances or where
mixtures are processed, stored or manufactured in such quantities that
combustion or explosion could constitute a hazard.
• In insufficiently ventilated rooms.
• In publicly accessible areas without supervision.
• In areas not protected against lateral ventilation.
• On tables, furniture items, wall-mounted shelving units etc.
2.4 SET-UP AND ASSEMBLY
The ebios-fire Quadra Inside is a ready-to-use item of equipment for instal-
lation in the top panel of a customized item of furniture (combustible materi-
als) or in an individually crafted, open fireplace (not combustible materials).
In the case of individually crafted fireplaces with the Quadra Inside, no
exhaust ducting is required.
The ebios-fire furniture item, whether free-standing or wall-mounted must
be set up horizontally and secured to prevent tilting.
The fireplace inserts may only be installed in recesses with a sufficient
load bearing capacity. If the load bearing capacity is not sufficient, suitable
measures must be taken (e.g., plate for load distribution) to remedy this.
NO modifications may be made to the design of the ebios fireplace insert.
2.5 GENERAL INSTRUCTIONS FOR INSTALLATION IN
TAILOR-MADE FIREPLACE CLADDING
• When designing tailor-made items of furniture, all the minimum dis-
tances and installation dimensions must be observed.
• The installation recess must have a sufficient load bearing capacity
• The ebios fireplace insert must be aligned horizontally
• The furniture items must always be secure to the wall or to the floor
respectively and secured to prevent accidental dislodgement, e.g. after a
collision impact and/or from being lifted up. To accomplish this, choose
appropriate fastening material.
• Installation in individually create fireplace cladding wood is permitted
only up to a body length of 1000mm. A lining of the insertion niche with
40mm calcium silicate boards is always needed.
• All inlet air apertures and rear ventilation points must be kept clear and
must not be obstructed because a heat build-up might otherwise occur.
Danger of fire!
• There must be an air gap of 10 mm around the body and be-tween the
panel and mounting wall. An air gap of 20 mm must be provided to the
rear (see the installation diagram fig. 1).
• The cross-section of the air intake opening for supplying air to and
cooling the burner is based on the burner type and must be positioned
in the direct vicinity of the body. Please refer to the relevant burner
instruction manual (automatic or wick burner) and the instructions under
Point 2.5.1.