background image

GB

 10

•  Ensure that the housing cover is closed and the protective panes are 

inserted.

•  It is recommended to open a window during operation.
•  Several decorative ethanol fireplaces may only be operated if the fuel 

consumption rate of all devices together does not exceed 0.5 l/h and if 
additional measures are taken to ensure sufficient ventilation. Please 
note the table on page 6 under point 2.1 for more details. Technical 
data.

•  The burner may only be operated with the burner mat and these wicks. 

It is not permitted to change the number of wicks, the wick material or 
the burner mat.

•  The ebios-fire furniture must not be modified. 
•  This is merely a decorative fireplace for use in the home and is not 

intended for heating or continuous operation! Nevertheless, it should 
be taken into account that heat (approx. 3 kW) is generated as a by-
product of the combustion process. Amongst other things this can cause 
increased heating in the room where the fireplace is installed.

•  There should never be any fuel in the tank and the cover must always be 

placed on the burner when the latter is not in use.

•  The burners are designed for the fuel to be burnt until all gone. If you 

only wish to enjoy the flames for a short period of time, use a cor-
respondingly smaller amount of fuel. If you wish to take the burner out 
of operation prematurely, place the cover on the burner with the aid of 
the grip stick. Allow the burner to rest for at least one hour after it has 
been extinguished! 

•  The burner must NOT be filled when warm or alight and must NOT be 

filled via the burner channel! 

DANGER TO LIFE!

•  The handling of fuel in the vicinity of the hot or burning device is associ-

ated with significant risks and is not permitted! 

•  Only fill the burner via the filling opening and never via the burner chan-

nel! (see Fig. 1). 

•  Should you accidentally spill ethanol, clean this up immediately and 

before lighting the burner! 

•  Please note that the luminosity of the flame can decrease to such an 

extent that the flame is no longer clearly visible. Make children and 
others in the home aware of this. 

•  Minimum waiting time between extinguishing and refilling the burner 

= 1 hour!

•  Do not smoke when handling fuel and operating the ebios-fire. 
•  Never extinguish the fire with water!!!

Failure to follow these basic rules can result in uncontrolled ignition or even 
explosions!

3.2 FIRE PROTECTION

There must be no flammable objects (decorations, clothing etc.) in the 
radiation area. In order to guarantee sufficient thermal insulation, there 
must be a minimum distance of 300 mm to flammable components at the 
side, furniture, decorations and curtains! There must be no objects between 
the fireplace and room ceiling (distance to the ceiling >1000mm)!

3.3 FUEL

Bioethanol (chemical formula C

2

H

6

O) with an ethanol content of 96% is used 

as the fuel, this is available from your specialist dealer. It is a dangerous 
substance as per ADR: Class 3 PG II, UN 1170. 

Содержание ebios-fire architecture SL

Страница 1: ...Installation and operating instructions ebios fire architecture SL GB...

Страница 2: ...our specialist partners we offer first class products which will touch your emotions and evoke a sense of security and comfort To achieve this we recommend that you read the operating instructions ca...

Страница 3: ...ly 14 4 Cleaning and care 15 4 1 Cleaning cladding parts 15 5 Maintenance troubleshooting 15 5 1 Furniture and glass depending on the model becomes sooted heavily rapidly and unevenly 15 5 2 Fire is d...

Страница 4: ...n Only allow the device to be refilled by individuals who are familiar with the safety instructions and who you been trained on its operation The ebios fire is not a heater but a decorative fire IMPOR...

Страница 5: ...de of Ceramat FN Safety container for all burner types made of stainless steel Cover plate with recess for grip stick made of stainless steel Bottle for moistening the burner mat Tank lock with seal F...

Страница 6: ...that the flame is no longer clearly visible Make children and others in the home aware of this These figures refer exclusively to the combustion air requirements of the Should you have additional air...

Страница 7: ...when not in use this can cause fuel in the tank to be expelled over the burner channel and accumulate in the safety tray In such cases the burner is to be removed and the tray emptied before the ebio...

Страница 8: ...least 2 people are required in order to set and move the concrete base Take care to prevent the edges and corners of the base from either being damaged or causing damage when moving it Slight imperfec...

Страница 9: ...on process which causes the burner the housing surfaces the glass panes depending on the model and the protective glass panes to heat up It is not permitted to touch these items without taking the nec...

Страница 10: ...burner with the aid of the grip stick Allow the burner to rest for at least one hour after it has been extinguished The burner must NOT be filled when warm or alight and must NOT be filled via the bu...

Страница 11: ...being ignited unintentionally or by unauthorised persons and to also stop the fuel from evaporating Please note that ethanol is used exclusively for combustion and it not suit able for consumption Su...

Страница 12: ...one out and has cooled down fully minimum waiting time after being extinguished 1 hour 3 The burner remains in the housing when being refilled For this remove the protective panes and then open the ho...

Страница 13: ...immediately and before lighting the burner Clean the surface of the burner until it is dry and completely free of ethanol 3 5 REFILLING THE BURNER The burner must NOT be filled when warm or alight an...

Страница 14: ...el is reached when the bioethanol runs out of the slit see arrow into the reflector curve Should you ever pour in too much fuel and cause the burner to overflow the ethanol collects in the safety cont...

Страница 15: ...around 190 l bioethanol Please contact your specialist dealer Only use our original spare parts The tank seal must be examined occasionally for cracks or brittleness and should be replaced if necessa...

Страница 16: ...h current statutory provisions 6 3 WARRANTY PERIOD The standard warranty terms only apply within Germany and the European Union The warranty period and scope of the warranty are ensured within the fra...

Страница 17: ...tion of defects shall take precedence The terms of this warranty shall not extend to any damage or compensation not covered by statutory provisions 6 7 EXTENSION OF THE WARRANTY PERIOD The warranty pe...

Страница 18: ...urniture stove and installed burner The builder con firms that all the points listed in these instructions have been taken into account and included in his design Furthermore the builder must hand ove...

Страница 19: ...GB 19 GB NOTE...

Страница 20: ...merk van wereldformaat voor uw woonkamer wiatowa marka do Pa stwa salonu 1 D Ihr Fachh ndler UK Your specialist dealer F Votre revendeur sp cialis IT Il vostro rivenditore specializzato E Sus comerci...

Отзывы: