background image

  Do  not  locate  receivers  close  to  other  high  frequency  trans-

other source of  interference  including,  ballasts, LED drivers, 
computers,  video equipment, Wi-Fi/LAN routers, GSM modems 

interference.  

Regulatory Statements

FCC Part 15.231 (315 and 902 MHz models only)

Contains FCC ID:  SZV-STM300C or SZV-STM300U
The enclosed device complies with Part 15 of the FCC Rules.

(I.) this device may not cause harmful interference and
(ii.) this device must accept any interference received, including 

IC RSS-210: (315MHz and 902 MHz models only)
ISO 9001: (only 315 MHz models that bear a MIC mark)     

Law Compliance. This device is granted pursuant to the Japanese Radio Law 
(                   

)

電波法

電気通信事業法

number will become invalid)

telephone: Toll Free: 1-888-554-4465, 1-450-424-6067 • fax: 1-450-424-6071
email: [email protected] • website: www.spartan-pd.com

Содержание WT913G

Страница 1: ...or product family includes WT913G NL Temperature Sensor Setpoint NOTE The WT913G is a solar powered device that absorbs solar energy storing it for use during low light periods Before assigning the RT...

Страница 2: ...ed to provide temperature control in the space that the sensor is monitoring for closed loop temperature control The sensor and receiver must be within range preferably in the same room ing 50 15 2 m...

Страница 3: ...tton RTS 2HS models only Users can override a room occupancy state by pressing the occupancy button on the lower right edge of the sensor LED Operation LEDs are on the right side of the solar panel Th...

Страница 4: ...place Linking the Temperature Sensor to a Receiver This process requires the controller or receiver to be mounted and pow ered and within range of the temperature sensor to be linked The sensor is a...

Страница 5: ...ttery holder and press the clip in with your finger Test Operating Modes Ensure the RTS is fully charged or insert a battery before entering test modes The following tests can be selected when in test...

Страница 6: ...nd only one re ceiver can be linked to the sensor for proper operation of the test disable repeaters in range for proper test operation 1 To enter Range Confirmation Test mode press and hold the occup...

Страница 7: ...r 0 10 Glass 0 10 Brick 5 35 MDF 5 35 Ferro concrete 10 90 Metal 90 100 Aluminum 90 100 Material Radio Range typical Line of sight 80 24m corridors Line of sight 150 46m open halls Plasterboard 80 24m...

Страница 8: ...300U The enclosed device complies with Part 15 of the FCC Rules I this device may not cause harmful interference and ii this device must accept any interference received including IC RSS 210 315MHz an...

Отзывы: