11
Operating Instructions
9 . Dial the throttle valve all the way closed (against the arrows on
the knob) and open the throttle valve, again, 1 to 2 full turns
before energizing the equipment and setting the pressure .
10 . The Cadet will operate up to 1,500 PSI with supplied open
nozzle (70700670) and 700 PSI with the supplied closed nozzle
(72705400) . If the machine is operating at a lower pressure, the
throttle valve knob can be turned in the open direction (following
the arrows on the knob) to increase the pressure . The operating
pressure is shown on the pressure gauge (see Fig . 5) .
11 . Open the inlet water valve . Energize the equipment with the
power switch and set your working pressure . See Chart 1 for
pressures and run times .
»
Use the lowest pressure whenever possible .
»
For every continuous cycle, allow the jetter to cool for a
minimum of 15 minutes .
FIG. 5
FIG. 6
12 . While working, always pull the water jet hose back one half
the distance advanced . The actual cleaning of the pipe takes
place when the hose is pulled back toward the operator .
Pulling the water jet hose backwards also ensures that the
hose is not caught in the pipe or has not exited the pipe .
13 . If the water jet hose fails to advance, it may be necessary to
pull off additional hose and twist the hose in a corkscrew-like
manner (see Fig . 6) .
14 . In those rare instances where backflow is created, a bilge
pump may be used (see Fig . 7) .
15 . When the pipe cleaning operation is complete, the Cadet
must be shut down in the following sequence to avoid
problems:
a . Turn off the motor switch
b . Turn off the water faucet
c . Close the water inlet valve
d . Unplug the electrical outlet
e . Disconnect the garden hose
f . Retrieve the HP hose
FIG. 7
Nozzle with
3⁄16" hose
10 minutes
continuous
20 minutes
continuous
30 minutes
continuous
70700670
open, 3/4 gpm
1500 psi
(max)
1250 psi
1000 psi
72705400
closed, 2 gpm
700 psi
(max)
600 psi
500 psi
CAUTION
Never operate the jetter for periods longer than the recommended continuous time
and never operate the jetter at maximum pressure for more than two 10-minute cycles per hour .
CHART 1
16. For more operating tips and troubleshooting, see the Cadet
Quick Guide in the organizer pocket of your Cadet.
Содержание CADET
Страница 3: ...3 Notes ...
Страница 16: ...16 Power Pack Assembly POWER PACK ASSEMBLY 3 3 4 4 5 5 6 6 7 7 8 8 23 24 25 16 20 ...
Страница 17: ...17 Power Pack Assembly POWER PACK ASSEMBLY 3 3 4 4 5 5 6 6 7 7 8 8 17 3 21 39 33 14 2 15 29 ...
Страница 19: ...19 Wiring Diagram WIRING DIAGRAM ...
Страница 22: ...CONTACT US Spartan Tool LLC 1618 Terminal Road Niles MI 49120 800 435 3866 SpartanTool com 70700000MAN 1907 ...