background image

P.O. Box 9792  

 

 Boardman, Ohio 44513

PH: (855)629-4648 

 Fax: (330)758-3314

www.spartanscientific.com

P.O. Box 9792  

 

 Boardman, Ohio 44513

PH: (855)629-4648 

 Fax: (330)758-3314

www.spartanscientific.com

Application and 

Installation Guide

Application and 

Installation Guide

A56-1620 Rev.00 

Series 4D85

Two-Way, Two Position, Normally Closed

Pressure 

Inlet 

P (1)

Pressure 

Outlet 

A (2)

A

P

Position 1)  Coil De-energized.   

 

Pressure inlet port P (1) is  

 

blocked to outlet port A (2).

Position 2)  Coil Energized. 

 

Pressure inlet port P (1) is

 

open to port A (2).

Series 4D85

Two-Way, Two Position, Normally Closed

Pressure 

Inlet 

P (1)

Pressure 

Outlet 

A (2)

A

P

Position 1)  Coil De-energized.   

 

Pressure inlet port P (1) is  

 

blocked to outlet port A (2).

Position 2)  Coil Energized. 

 

Pressure inlet port P (1) is

 

open to port A (2).

Excessive use of pipe sealant can cause clogging and leakage.  Please follow ASME standards for applying pipe 

sealant and tape.  Do not use media, voltage or pressures other than that recommended by Spartan Scientific Inc. as 

valve malfunction could result. Misuse or misapplication of Spartan solenoid valves could cause serious bodily injury 

or property damage.

Caution

Solenoid valves and all other products manufactured by Spartan are warranted by Spartan to be free from defects in 

material and workmanship for a period of 1 year from the date of purchase. Spartan's obligation under this warranty is 

limited to repair or replacement of the defective product or refund of the purchase price paid solely at the discretion of 

Spartan and provided such defective product is returned to Spartan freight prepaid and upon examination by Spartan 

such product is found defective. This warranty shall be void in the event that the product has been subject to misuse, 

misapplication, improper maintenance, modification or tampering. This warranty is expressed in lieu of all other war

-

ranties, expressed or implied from Spartan Scientific, Inc., representatives or employees.

Warranty Information

Excessive use of pipe sealant can cause clogging and leakage.  Please follow ASME standards for applying pipe 

sealant and tape.  Do not use media, voltage or pressures other than that recommended by Spartan Scientific Inc. as 

valve malfunction could result. Misuse or misapplication of Spartan solenoid valves could cause serious bodily injury 

or property damage.

Caution

Solenoid valves and all other products manufactured by Spartan are warranted by Spartan to be free from defects in 

material and workmanship for a period of 1 year from the date of purchase. Spartan's obligation under this warranty is 

limited to repair or replacement of the defective product or refund of the purchase price paid solely at the discretion of 

Spartan and provided such defective product is returned to Spartan freight prepaid and upon examination by Spartan 

such product is found defective. This warranty shall be void in the event that the product has been subject to misuse, 

misapplication, improper maintenance, modification or tampering. This warranty is expressed in lieu of all other war

-

ranties, expressed or implied from Spartan Scientific, Inc., representatives or employees.

Warranty Information

A56-1620 Rev.00 