background image

www.spartacogroup.com 

 800-860-6170

6

OPERATING INSTRUCTIONS

  Compression

  MAINTENANCE AND INSPECTION

1.  Daily maintenance is required to ensure that the tool is kept in good working condition.
2.  Do not store the tool in a humid environment.
3.  Wipe away any excess oil with a soapy cloth.
4.  Provided that maintenance of the tool is carried out regularly, the tool should provide  

 

many years of service.

5.  Should you experience any difficulty with the operation and maintenance of this tool,  

 

contact Huskie’s technical support department at 1-800-860-6170.

1.  Before connecting the tool head, make sure the pump and hose being used is working 

properly, and adjusted to and rated at 10,000 psi. The use of a pump or hose not rated 
at 10,000 psi working pressure may cause severe damage and result in personal injury.

2.  Connect the tool head to the pump and hose, making sure all coupler connections are 

secure. It is important that all connections are tight for tool to function properly.

3.  Select appropriate compression die set for the connector and cable being used. The 

“U” style Huskie HT-41 series dies are to be used with these tools

4.  To insert the dies, depress the die release pin on the ram, and slide die into place. Then 

lift release knob on top of “C” head and slide other die half in place. Be sure both die 
halves are secure before operating the tool.

5.  Position the connector between the dies and operate pump to hold connector in place. 

Fully insert cable into the barrel of the connector and operate pump as described 
in the pump operations manual until connector is fully crimped. For pumps that are 
not equipped with a hold feature, connector and cable must be in alignment before        
operating the pump.

6.  Always be sure to keep couplers clean and caps in place when the tool is not being 

used.

Содержание Huskie Tools EP-510HC

Страница 1: ...n Remote Compression C Head Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendale Heights IL 60139...

Страница 2: ...bution markets Huskie Tools products represents the state of the art tools and are dependable safe Trust integrity teamwork and mutual respect these words are something we take to heart here at Huskie...

Страница 3: ...containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone o...

Страница 4: ...ye protection when operating this tool Failure to wear eye protection could result in serious eye injury from flying debris Electric Shock hazard Use proper personal protective equipment when using th...

Страница 5: ...p to 750 MCM Cu Features The EP 510HC is a remote C head that requires an external 10 000 psi pumping source It accepts all U type dies used with conventional 12 ton compression tools The larger jaw o...

Страница 6: ...al injury 2 Connect the tool head to the pump and hose making sure all coupler connections are secure It is important that all connections are tight for tool to function properly 3 Select appropriate...

Страница 7: ...efore use TROUBLESHOOTING FOR THE TOOL 1 Never operate tools without dies in place Failure to insert dies before operation will cause damage to the C frame and tool ram 2 Never attempt to adjust press...

Страница 8: ...www spartacogroup com 800 860 6170 8 BREAKDOWN...

Страница 9: ...0 06 1 14 Retainer Pin B 410 12 1 15 Spring 177 410 01 1 16 2 5 X 14 Drive Pin BW 410 11 1 17 Ram 510HC 03 1 18 Die Release Pin 430 21 1 19 2 5 x 8 Dowel Pin B 410 17 1 20 P 42 Back Up Ring B C 510 18...

Страница 10: ...www spartacogroup com 800 860 6170 10 NOTES...

Страница 11: ...www spartacogroup com 800 860 6170 11 NOTES...

Страница 12: ...195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com...

Отзывы: