background image

Page 16

Measurements and Diagrams

All measurements in parenthesis are in millimeter.

All inch measurements are converted from millimeters, thus inch measurements are estimated.

Page 16

Without optional single-piece chimney:

With optional single-piece chimney:

Содержание UCH18 Pro Turbo Series

Страница 1: ...SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance Keep these instructions for future reference 30 05 2018 UCH18 Pro Series Turbo 48 in MAAN1272 02 ...

Страница 2: ...orities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...

Страница 3: ...with a close fitting lid cookie sheet or metal tray then turn OFF the burner BECAREFUL TO PREVENT BURNS NEVER PICK UPA FLAMING PAN you may be burned KEEP FLAMMABLE OR COMBUSTIBLE MATERIALAWAY FROM FLAMES If the flames DO NOT go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or 911 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONL...

Страница 4: ... requirements 8 Preparation 9 Installation 10 11 Range hood operations 12 13 USE AND CARE Troubleshooting 14 Use and care information 15 Specifications 15 Measurements Diagrams 16 22 MAINTENANCE Cleaning 23 Replacing the filter light bulb 23 Tools needed Page 3 Level Flat blade and Phillips screwdrivers Powered screwdriver or drill Measuring tape Utility knife Marker or pencil ...

Страница 5: ...2PCS Baffle Filter Qty 3 PCS Grease Tunnel Qty 1 PCS Type C For Hood mounting Bracket Length 3 10 Qty 8 1 PCS Single piece Chimney Optional sold separately 6 baffle filter handle 12 1 pcs filter handle screws Qty 20 1 pcs Round head Under Cabinet Range Hood 2 Tape for ducting transition Hood mounting Bracket Qty 2 PCS ...

Страница 6: ...recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm or bigger round metal aluminum vent work The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows ...

Страница 7: ...d be no higher than 30 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Due to differe...

Страница 8: ...r terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal aluminum duct work only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Use caulking to seal exterior wall or roof opening around the cap Vertical roof venting Roof cap Option 2 Side wall cap Horizontal ...

Страница 9: ...l or ground circuit IMPORTANT Save this Installation Guide for electrical inspector s use The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable ETL listed strain relief must be provided at each end of the power supply cable Wire sizes copper...

Страница 10: ...e hood IMPORTANT Peel white plastic protective coat off the hood if any Use silver tape or duct tape to seal joints between pipe sections For installing under the cabinet with recessed bottom attach 4 inch wide wood filler strips not provided on each side Refer to Figure 1 Using references in Measurements and Diagrams on Page 16 create access opening for electrical wires and hood exhaust under the ...

Страница 11: ... recommended B 3 Puncture the knockout wire access hole at the back of the hood and draw the electrical wires through as shown in Figure 4 Attach each hood mounting bracket to the back of the hood with 4 flat head screws as shown in Figure 5 B 4 Align hood mounting bracket to the screws on the wall and hook hood into place as shown in Figure 6 B 5 Tighten screws to secure hood to the wall CAUTION M...

Страница 12: ...pacer placement Refer to Figure 10 for the following five steps Angle baffle filter toward back of hood Push baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits into resting positions Repeat Step 8 to install all baffle filters and stainless spacers 9 OPTIONAL Install heating lamps not included last 120 Volt 250 Watt maximum per...

Страница 13: ...pressed before a Speed Control button can be activated NOTE The light setting will not be affected by the Power Control On Off button Press the Power Control On Off button once The four LED Speed Indicators above the Speed Control will flash if a Speed Control button is not pressed within 10 seconds power will be turn OFF automatically While the LED Speed Indicators are flashing press a Speed Contro...

Страница 14: ... Indicator not flashing press the Power Control On Off twice to turn OFF the fans Light Control Light Control button operates independently from the Power Control On Off and power off delay function Pressing the Power Control On Off button or activating the delay function will not turn LED lights ON or OFF CAUTION DO NOT touch the lights until switched OFF While the LED lights are OFF press the Lig...

Страница 15: ... insufficient duct size For example 9 duct over 8 hole and loosely secured Check if duct is clogged or if damper unit half cir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattling The blower might be jammed or scraping the bot tom du...

Страница 16: ...up at all times to prevent possible fires Filters must be cleaned periodically and free from accumulation of cooking residue see cleaning instructions on Page 23 Old and worn filters must be replaced immediately DO NOT operate blowers when filters are removed Never disassemble parts to clean without proper instruc tions Disassembly is recommended to be performed by qualified personnel only Read and un...

Страница 17: ...iagrams All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated Page 16 Without optional single piece chimney With optional single piece chimney ...

Страница 18: ...age 17 All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated Without hood mounting bracket With hood mounting bracket ...

Страница 19: ...Page 18 Rear Knockout Holes All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated Hood mounting Bracket ...

Страница 20: ...Baffle Filters and Stainless Steel Spacers Circuit Diagram Page 19 ...

Страница 21: ... 2 Screw for Mounting Bracket 11 Light Panel 3 Mounting Bracket 12 LED Light 4 Power Cord 13 Stainless Steel Spacer 5 Ducting Transition 14 Baffle Filter Handle 6 Screw for Ducting Transition 15 Screw for Light Panel 7 Blower 16 Control 8 Electrical Assembly 17 Baffle Filter 9 Panel 18 ...

Страница 22: ... 4 5 Motor 4 2 Air Flow Grill 4 6 Right Squirrel Cage 4 3 Left Locknut 4 7 Right Locknut 4 4 Left Squirrel Cage 4 8 Air Chamber Optional Single Piece Chimney Sold Separately No Description No Description 3 Screws 3 16 x 3 8 24 Single Piece Chimney Cover Size Varies ...

Страница 23: ...e 22 Electrical Assembly No Description No Description 21 1 Bolt 21 6 Electrical Box Base 21 2 Electrical Box 21 7 Screw 21 3 Screws 21 8 Capacitor 21 4 Processor Board 21 9 Screw 21 5 Electrical Box Cover ...

Страница 24: ...Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Stainless Steel Baffle Filter IMPORTANT Drain oil from baffles sp...

Отзывы: