Page 10
Installations
(refer to Page 4 for parts)
:
Measure the distance between stove top and the bottom of
range hood. A distance of 28” to 31” is recommended*.
*Due to different ceiling height configurations, recom
-
mended height may not be applicable.
Using references in
1.
Height & Clearance
on Page 5 and
Measurements and Diagrams
on Page 15, mark the lev
-
eling point of the hood. Position two mounting screws on
the wall, leaving 1/8” space away from the wall.
Measure the width of the chimney then attach the chim
-
2.
ney-mounting brackets to the wall as high as you want
the upper chimney to be.
NOTE: Use threaded drywall anchors only when mount-
ing the hood on sheet rock. Mounting the hood on wall
studs or lumbars is highly recommended.
Align hood-mounting holes to the screws on the wall and
3.
hook the hood into place. Tighten screws to secure hood
to the wall.
CAUTION: Make certain the range hood
is secure before releasing!
Connect the venting duct between the hood and the exhaust opening either on the ceiling or wall. Use silver
4.
tape or duct tape to make all joints secure and air tight.
Connect the range hood to a designated standard outlet (please refer the product label for the suitable voltage
5.
of this unit) or cut off the plug and connect three wires (black, white and green) to house wires and cap with
wire connectors. Connect according to colors (i.e. black to black, white to white, and green to green).
SAFETY WARNING: Risk of electrical shock. This range hood must be properly grounded. Make sure
this is done by qualified electrician in accordance with all applicable national and local electrical codes.
Before connecting wires, switch power off at service panel and lock service panel to prevent power from
being switched on accidentally.
Installation
Figure 1
Figure 3
Figure 4
Figure 2