background image

Important Safety Notice

Read all Instructions before Installing and operating this appliance

•  The installation in this manual is intended for qualified installers, service technicians or persons with 

similar qualified background. Installation and electrical wiring must be done by qualified profession

-

als and in accordance with all applicable codes and standards, including fire-rated construction.

• 

DO NOT

 attempt to install this appliance yourself. Injury could result from installing the unit due to 

lack of appropriate electrical and technical background.

•  Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any 

parts for installing, cleaning or servicing.

•  Activating any switch ON before completing installation may cause ignition or an explosion.

•  Due to the size and weight of this range hood, two people installation is recommended.

 

To reduce the risk of fire, electric shock, or injury to persons:

•  For general ventilating use only. 

DO NOT

 use to exhaust hazardous or explosive materials and va

-

pors.

•  The combustion air flow needed for safe operation of fuel-burning equipment may be affected by this 

unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such 

as those published by the National Fire Protection Association (NFPA), and the American Society of 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

•  Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre

-

vent power from being switched ON accidentally.

•  Clean grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make 

sure to vent air outside. DO NOT

 vent exhaust into spaces between walls, crawl spaces, ceiling, attics 

or garages.

•  Ducted fans MUST always be vented to the outdoors.

•  Use only metal ductwork and this unit MUST be grounded.

•  Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent 

back drafting.

•  When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid

-

den utilities.

•  All electrical wiring must be properly installed, insulated and grounded.

•  Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire.

•  Check all joints on duct work to insure proper connection and all joints should be properly taped.

•  Use this unit only in the manner intended by the manufacturer. If you have questions, contact the 

vendor.

To reduce the risk of a stove top grease fire:

•  Keep all fan, baffle, spaces, filter, grease tunnel, oil container and grease-laden surfaces clean. Grease 

should not be allowed to accumulate on fan, baffle, spaces, filter, grease tunnel and oil container.

•  Always turn range hood ON when cooking at high heat or when cooking flaming foods. 

•  Use high settings on cooking range only when necessary.

•  Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers 

that may ignite. Heat oils slowly on low or medium settings.

Page 1

Содержание PS19

Страница 1: ...nual Professional Built in hood Professional Insert Liners IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference Rev 2036u 1c Spagna Vetro PS19 ...

Страница 2: ...rities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...

Страница 3: ...er and or distributor reseller further declines all responsibility for injury due to neg ligence and the warranty of the unit automatically expires due to improper maintenance The manufacturer and or distributor reseller will not be held responsible for any damages to per sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood Clean ventilating ...

Страница 4: ...tant to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm or bigger round metal aluminum vent work Always use rigid type metal aluminum ducts if a...

Страница 5: ...d mounting height above range Due to different ceiling height configurations recommended height may not be applicable Minimum Duct Size Round 8 minimum Rectangular 3 1 4 x 10 minimum requires a provided 3 1 4x10 adaptor Duct Run Calculation Recommended maximum run 8 or 3 1 4 x 10 duct 50 ft Vent piece deduction Each 90º elbow used 9 ft Each 45º elbow used 5 ft Each 8 to 3 14 x 10 transition used 7...

Страница 6: ...Valley Road Cleveland Ohio 44131 5575 Advanced Preparations 1 Be familiar with the controls of the range hood by reading through Range Hood Operations Page 12 2 Place the range hood on a flat stable surface Connect the range hood to a designated standard outlet please refer the product label for the suitable voltage of this unit and turn on the range hood Verify all operations of the range hood by...

Страница 7: ...al shock this range hood must be properly grounded Make sure this is done by qualified electrician in accordance with all applicable national and local electrical codes Before connecting wires switch power off at service panel and lock service panel to prevent power from being switched on accidentally 7 Connect the range hood to a designated standard outlet or cut off the plug and connect three wi...

Страница 8: ...hood before cooking and allow it to operate several minutes after the cooking is completed to clear all smoke and odors from the kitchen Button functions Power Power ON OFF the range hood and activate power off delay timer Decrease Value Blower motor speed decrease timer value decrease and enter timer mode Increase Value Blower motor speed increase timer value increase and cleaning reminder reset ...

Страница 9: ...arette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep fryers during use Superheated oil may be flammable Cleaning The saturation of greasy residue in the ...

Страница 10: ...ted from millimeters thus inch measurements are estimated Professional Insert Liner Wiring Diagram 4 Speed NOTE Wiring Diagrams shown above with GU10 light configuration A transformer is required for MR16 Lights Wiring Diagram 6 Speed Measurements Wiring Diagram Continued Measurements Wiring Diagram ...

Страница 11: ...You must present proof of original purchase date Please provide an original dated proof of purchase sales receipt invoice in order to obtain service under warranty The information in this document is subject to change without notice please contact your local reseller for updated details Warranty SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal ope...

Страница 12: ... A restocking fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty ...

Страница 13: ...Spagna Vetro Appliances Inc Burnaby BC Canada www KitchenHoods ca tel 604 430 5252 SPAGNA VETRO ...

Отзывы: