Form 43343050
-34-
Jan 2014
Fresh Air Intake Assembly
(Part No. 44129000)
Slide fresh air intake
into hole and secure
flange with screws (4 each).
4 Flexible Air Inlet Hose
2 Ft. Long
(Part No. 30675020)
4 Starting Collar
(Part No. 30504040)
Control Box
(End View)
Ceiling
4 Spring
Tension Clamp (2 each)
(Part No. 30676040)
Cut hole in ceiling
approximately
4-1/4 diameter.
Note: This hole location
should allow the hose enough
room to expand and contract with
the heater.
Step A
Step B
Compress end of
flexible hose.
Squeeze ears of
spring clamp and slide
over compressed end
of flexible hose.
Step D
Step E
Slide hose and clamp onto
starting collar of control.
Repeat steps D & E on opposite
hose end for connection to
fresh air intake.
Step F
Cold Air Stopper (supplied as accessory)
(Part No. 30683000)
Flapper
Side
Step C
Slide cold air stopper
into starting collar. Make
sure that flapper side is
facing outward as shown.
Roof Ridge V
ent
The fresh air intake is not an
outdoor terminal.
DO NOT
penetrate through roof.
Improper operation of the heater
will occur.