SIM Inverter Monobloc Air-to-Water Heat Pump

SpacePak Buffer Tanks

 

The “Manufacturer” warrants to the original owner at the original installation site that the Hydronic Buffer Tanks 

(the “Product”) will be free from defects in material or workmanship for a period not to exceed ten (10) years from 

the startup, provided the product is installed in accordance with the manufacturers installation instructions. If 

upon examination by the Manufacturer the Product is shown to have a defect in material or workmanship during 

the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown 

to be defective.

The following items apply to each Limited Warranty offered by SpacePak.

4)  NO LABOR. Each Limited Warranty offered by SpacePak does NOT include labor or any other costs incurred 

for service, maintenance, repair, removing, replacing, installing, complying with local building and electric codes, 

shipping or handling, or replacement of the System/Products, compressors or any other parts. For items that are 

designed to be maintained or replaced by the original owner, the original owner is solely responsible for all labor 

and other costs of maintaining, installing, replacing, disconnecting or dismantling the System/ Products and 

parts in connection with owner-required maintenance. Please consult the applicable technical documentation 

for regularly suggested maintenance procedures.

5)  PROPER INSTALLATION. This Limited Warranty applies only to Systems/Products that are sold by SpacePak 

HVAC representatives, installed by contractors who are licensed for HVAC installation under applicable local 

and state law, and who install the Systems/Products in accordance with (i) all applicable building codes and 

permits: (ii) SpacePak’s installation and operation instructions: and (iii) good trade practices.

6)  BEFORE REQUESTING SERVICE, please review the applicable technical documentation to insure proper 

installation and correct customer control adjustment for the System/Products. If the problem persists, please 

arrange for warranty service.

a.  

TO OBTAIN WARRANTY SERVICE:

i.  Contact the licensed contractor who installed the System/Products or the nearest licensed contractor, 

dealer, or distributor (whose name and address may be obtained on our website at www.SpacePak.

com of any defect within the applicable warranty time period.

ii.  Proof of the installation date by a licensed contractor is required when requesting warranty service. 

Present the sales receipt, building permit or other document which establishes proof and date of 

installation. In the absence of acceptable proof, this Limited Warranty shall be deemed to begin one 

hundred twenty (120) days after the date of manufacture stamped on the System/Products.

iii.  This Limited Warranty applies only to System/Products purchased on or after February 1, 2021 only 

while the System/Products remains at the site of the original installation, and only to locations within 

the continental United States, Alaska, Hawaii and Canada.

iv.  Shipment, to the Manufacturer, of that part of the Product thought to be defective. Goods can only 

be returned with prior written approval from the Manufacturer. All returns must be freight prepaid. 

Determination, in the reasonable opinion of the Manufacturer, that there exists a defect in material 

or workmanship.

b.  THIS LIMITED WARRANTY DOES NOT COVER: property damages, malfunction or failure of the System/

Products, or personal injury caused by or resulting from: (a) accident, abuse, negligence or misuse; (b) 

operating the System/Products in a corrosive or wet environment, including those containing chlorine, 

fluorine or any other hazardous or harmful chemicals or environmental factors, including sea- or salt-water; (c) 

installation, alteration, repair or service by anyone other than a licensed contractor or other than pursuant to 

the manufacturer’s instructions; (d) improper matching of System/Products components; (e) improper sizing 

of the System/Products; (f) improper or deferred maintenance contrary to the manufacturer’s instructions; 

(g) physical abuse to or misuse of the System/Products (including failure to perform any maintenance as 

described in the Operation manual, or any System/ Products damaged by excessive physical or electrical 

stress; (h) System/Productss that have had a serial number or any part thereof altered, defaced or removed; 

(i) System/Products used in any manner contrary to the Operation Manual; (j) freight damage; or (k) events 

of force majeure or damage caused by other external factors such as lightning, power surges, fluctuations 

in or interruptions of electrical power, rodents, vermin, insects, or other animal- or pest-related issues.

c.  THIS LIMITED WARRANTY ALSO EXCLUDES: (a) SERVICE CALLS WHERE NO DEFECT IN THE 

SYSTEM/PRODUCTS COVERED UNDER THIS WARRANTY IS FOUND: (b) System/Products installation 

or set-ups; (c) Adjustments of user controls; (d) System/Products purchased or installed outside the 

continental United States, Alaska, Hawaii and Canada; or (e) System/Products purchased or installed prior 

to February 1, 2021. Consult the operating instructions for information regarding user controls.

Содержание CSOLSTICE SIM-036

Страница 1: ...n Location Water Loop Connection Electrical Connections Control Input Connections Control Output Connections Dimensions Required Clearances SECTION 3 GLYCOL WATER SYSTEM 13 SECTION 4 WIRING 15 Control...

Страница 2: ...the air to refrigerant heat transfer and the refrigerant to water energy transfer Low Ambient Temperature Cooling Operation SIM heat pump is capable of operating in cooling mode in ambient temperature...

Страница 3: ...26 10 75 Efficiency IPLV 12 2 12 1 Delivered Water Temp Range DegF 41 68 Ambient Temp Range DegF 50 110 Heating Capacity Range BTU hr 13 191 38 755 25 413 70 666 Efficiency Range COP 5 01 4 04 4 67 3...

Страница 4: ...Compressor Frequency SIM 036 Heat Capacity 122F RWT 30 40 50 60 70 80 90 Cooling Capacity 8 128 10 757 16 904 20 285 23 768 26 603 30 837 BTU hr EER 9 90 10 14 10 24 10 00 9 62 9 42 9 22 Cooling Capa...

Страница 5: ...city EER Minimum Capacity 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0 5 000 10 000 15 000 20 000 25 000 30 000 35 000 5 19 36 45 COP r h U T B y t i c a p a C g n i t a e H Ambient Temperatur...

Страница 6: ...80 9 Capacity BTU Compressor Frequency SIM 060 Heat Capacity 122F R 30 40 50 60 70 80 90 Cooling Capacity 14 915 26 724 32 389 34 915 41 366 45 973 49 591 BTU hr EER 9 83 9 93 10 07 10 04 9 78 9 39 9...

Страница 7: ...aximum Capacity EER Minimum Capacity 1 2 3 4 5 6 7 8 9 10 0 10 000 20 000 30 000 40 000 50 000 60 000 5 19 36 45 COP r h U T B y t i c a p a C g n i t a e H Ambient Temperature F 122 F Returning Water...

Страница 8: ...8 SIM Inverter Monobloc Air to Water Heat Pump Typical System Diagram SIM Heating with DHW Offset Applicable to SIM 036 and SIM 060...

Страница 9: ...esult The total system must be protected with a Pressure Relief Valve or valves sized to protect the system component with the lowest pressure rating In no instance shall this exceed 30PSI Caution It...

Страница 10: ...relay contact capable of switching 24 to 240VAC at a low current to operate a contactor which engages electric or any supplemental heat source according the selected parameters This connection is loca...

Страница 11: ...11 SIM Inverter Monobloc Air to Water Heat Pump Dimensions Unit Dimensions inch mm SIM 036 Top View Top View Front View Front View Side View Side View SIM 060...

Страница 12: ...12 SIM Inverter Monobloc Air to Water Heat Pump Required Clearances Unit shall be mounted per local codes and high enough off ground to allow for proper condensate drainage...

Страница 13: ...ion 26 F 3 C 18 F 8 C 8 F 13 C 7 F 22 C 29 F 34 C SpacePak Capacity Multiplier 0 99 0 98 0 96 0 93 0 88 Pressure Drop Multiplier Cooling 1 10 1 20 1 34 1 5 1 65 Pressure Drop Multiplier Heating 1 10 1...

Страница 14: ...System Volume and Expansion Volume To ensure smooth temperature control and minimize cycling of refrigeration system all installations must have total circulating volumes equal to or greater than 7 5...

Страница 15: ...ll not operate on the 24V signals from typical thermostats or air handlers Connecting 24V to either of these points will result in signi cant component damage Connect multiple zone system to heat pump...

Страница 16: ...nd Definitions Internal Wiring SIM 036 CAUTION The Remote On Off Remote Heat Cool Heat Cool On Off and DHW On OFF inputs are for voltage free relay contacts only Any voltage introduced to the controls...

Страница 17: ...On Off Remote Heat Cool Heat Cool On Off and DHW On OFF inputs are for voltage free relay contacts only Any voltage introduced to the controls at these points will immediately destroy the primary uni...

Страница 18: ...nd Definitions Internal Wiring SIM 060 CAUTION The Remote On Off Remote Heat Cool Heat Cool On Off and DHW On OFF inputs are for voltage free relay contacts only Any voltage introduced to the controls...

Страница 19: ...d Definitions Field Connections SIM 060 CAUTION The Remote On Off Remote Heat Cool Heat Cool On Off and DHW On OFF inputs are for voltage free relay contacts only Any voltage introduced to the control...

Страница 20: ...Function of the Ports Display Windows and Functions If the display screen is not touched in 30s the screen will dim The screen will go to sleep after 2 minutes of no operation Touching the screen will...

Страница 21: ...he unit will still have power going to it The main display will then turn grey Return Key In each sub menu not the main interface the user can use the return key to return to the previous screen This...

Страница 22: ...mode the display will show cooling 4 When choosing Hot Water Heating mode the display will show hot water and heating 5 When choosing Hot Water Cooling mode the display will show hot water and coolin...

Страница 23: ...screen and then entering in a numeric value within specified parameters in the control see parameter chart for min and max settings Once a target is set the user will need to press enter to save the s...

Страница 24: ...or example If a user does not want the unit to run on Monday from 11 AM 2PM Select Mon at the bottom red arrow should be under the day Select AM and press the clock on the 11 12 block and the 1 2 bloc...

Страница 25: ...ature being measured 4 Outlet Water Temp Displays the current outlet water temperature being measured 5 Tank Water Temp Displays the domestic hot water tank temperature if used If installed see wiring...

Страница 26: ...selecting and adjusting the appropriate parameters see parameter chart to provide supplemental heat when desired To turn the feature on press the electric heating key and choose on To turn off choose...

Страница 27: ...e fans down to provide a quieter operation However the fast whisper will also decrease capacity Use only when quiet operation is required To turn off press Fast Whisper again Fast Whisper may also be...

Страница 28: ...istorical the operational curves of the inlet water outlet water and ambient on graph of temperature versus time period Settings Factory The factory key allows the user to enter in a password that wil...

Страница 29: ...word 22 the following menus appear Settings Factory Passcode 22 Parameters Parameters Submenu Press this key to access certain parameters only meant to be changed by a user Use the parameter chart fro...

Страница 30: ...is Heating S06 DHW On Off Open Closed Indicates DHW enabled by an external switch S07 Electric Heater Overload Open Closed Auxiliary Electric Heater Safety Switch Closed allows normal heater operatio...

Страница 31: ...f the fault will all be recorded and displayed The log is capable of holding the most recent 35 faults The fault log can be cleared by pressing the Clear button in the upper right hand corner and then...

Страница 32: ...just the screen brightness Press the brightness bar to the right to make the display brighter and the left on the brightness bar to make the display less bright Settings Factory Passcode 66 Password 6...

Страница 33: ...tric Heat During Defrost 0 1 66 0 0 If 0 no action If 1 aux heat is energizes during Defrost D11 Compressor Speed during Defrost Hz 30 to 90 66 70 70 Fixed compressor speed during Defrost only EEV E01...

Страница 34: ...on H03 Temperature Units 0 1 66 1 1 0 Temps displayed in C press in Bar 1 Temps in F press in PSI H04 4 way valve polarity 0 1 66 0 0 0 Reversing Valve de energized in heating 1 RV energized in Heatin...

Страница 35: ...ive when the water temp is below R02 R13 R14 Electric Heat Start AT Deg F 14 to 86 66 41 41 Electric Heat is active after delay when the Amb Temp is below R14 R15 Delay of Electric heater Min 0 to 60...

Страница 36: ...r the suction pressure parameter A02 the unit will restart to run automatically 2 If the protection happens over 3 times within 30min the unit won t be restarted automatically Recovery only by manual...

Страница 37: ...of D11 The following operations shall be conducted if it complies with stop defrosting requirements a The compressor start to down the frequency at the target frequency of 30Hz timings start b The fa...

Страница 38: ...ing the timing mute will result in the time mute failure 2 When F10 1 enable the timing mute function During the time of F11 F12 including F11 excluding F12 if the fan needs to be turned on it will ru...

Страница 39: ...pressor is not running the pump will start every P02 minutes and run for the duration of P03 minutes in order to circulate wate from the system through the Heat Pump so that it can sample the water te...

Страница 40: ...Format 2 Connect the wire from the BMS to the terminal labeled RS485 in the SIM electrical cabinet and wire from the BMS to the terminal labeled RS485 in the SIM electrical cabinet Locate a GND if re...

Страница 41: ...6 Hot water function 0 disable 1 enable DIGI1 1034 03 16 06 40A H17 Cooling mode 0 disable 2 enable DIGI1 1035 03 16 06 40B Reserved 1036 03 16 06 40C Reserved 1037 03 16 06 40D Reserved 1038 03 16 06...

Страница 42: ...click mute 0 off 1 on DIGI1 1075 03 16 06 433 Reserved 1076 03 16 06 434 Reserved 1077 03 16 06 435 Reserved 1078 03 16 06 436 Reserved 1079 03 16 06 437 Reserved 1080 03 16 06 438 Reserved 1081 03 16...

Страница 43: ...rved 1166 03 16 06 48E Reserved 1167 03 16 06 48F P01 Working mode of circulating water pump 0 normal 1 special 2 intermittent DIGI1 1168 03 16 06 490 P02 Circulating water pump running time interval...

Страница 44: ...1238 03 16 06 4D6 Reserved 1239 03 16 06 4D7 Reserved 1240 03 16 06 4D8 Reserved 1241 03 16 06 4D9 Reserved 1242 03 16 06 4DA Reserved 1243 03 16 06 4DB Reserved 1244 03 16 06 4DC Reserved 1245 03 16...

Страница 45: ...03 802 T06 Coil temperature TEMP1 2051 03 803 T07 Ambient temperature TEMP1 2052 03 804 T08 Suction pressure TEMP1 2053 03 805 T09 Exhaust pressure TEMP1 2054 03 806 T10 Actual frequency DIGI1 2055 0...

Страница 46: ...ter tank temperature sensor failure 0 no 1 yes bit4 Suction temperature sensor failure 0 no 1 yes bit5 Coil temperature sensor failure 0 no 1 yes bit6 Ambient temperature sensor failure 0 no 1 yes bit...

Страница 47: ...t14 Reserved 2090 03 82A Failure bit0 Reserved bit1 Reserved bit2 Reserved bit3 Reserved bit4 Reserved bit5 Reserved bit6 Reserved bit7 Reserved bit8 Reserved bit9 Reserved bit10 Reserved bit11 Reserv...

Страница 48: ...r lower water temperature E02 Low Pressure Dischare Pressure Excessive refrigerant discharge pressue If in Cooling insufficient water flow If in Heatinging restricted airlow or dirty coil Correct wate...

Страница 49: ...49 SIM Inverter Monobloc Air to Water Heat Pump SECTION 7 TROUBLESHOOTING Possible Cause Possible Solution...

Страница 50: ...50 SIM Inverter Monobloc Air to Water Heat Pump Troubleshooting continued Possible Causes for the Failure Possible Solutions...

Страница 51: ...51 SIM Inverter Monobloc Air to Water Heat Pump SECTION 8 REPLACEMENT PARTS SIM036...

Страница 52: ...52 SIM Inverter Monobloc Air to Water Heat Pump Replacement Parts SIM036...

Страница 53: ...53 SIM Inverter Monobloc Air to Water Heat Pump Replacement Parts SIM060...

Страница 54: ...54 SIM Inverter Monobloc Air to Water Heat Pump Replacement Parts SIM060...

Страница 55: ...9 01 Heat exchanger refrigerant to water X 45W50 WG1262 01 X 17 45W40 WG1210 01 Manifold Water outlet X 45W40 WG1210 03 X 18 45W11 WG1211 01 Flow switch X X 19 45W11 WG1212 01 Pressure sensor 0 45bar...

Страница 56: ...X 40 45W09 WG1229 01 Fan speed module IC3 X X 41 45W09 WG1230 01 EMI Filter IC4 X 45W09 WG1230 02 X 42 45W09 WG1231 01 Inverter Compressor drive IC2 X 45W09 WG1231 02 X 43 45W09 WG1232 01 Control Boar...

Страница 57: ...rter outdoor and indoor components connected via refrigerant piping and electrical wiring purchased on or after February 1 2021 i sold from a licensed HVAC representative of SpacePak and not an unauth...

Страница 58: ...ty service Present the sales receipt building permit or other document which establishes proof and date of installation In the absence of acceptable proof this Limited Warranty shall be deemed to begi...

Страница 59: ...59 SIM Inverter Monobloc Air to Water Heat Pump...

Страница 60: ...IN UNITED STATES 260 NORTH ELM ST WESTFIELD MA 01085 800 465 8558 FAX 413 564 5815 IN CANADA 7555 TRANMERE DRIVE MISSISSAUGA ONTARIO L5S 1L4 905 670 5888 FAX 905 670 5782...

Отзывы: