Congratulations

on choosing the latest Spa Power 600 control system. This

controller makes use of the latest technology, including innovative optical and digital sensor
designs. The greater variety of optional accessories, user-friendly touchpad and reliable
components provide you with the most sophisticated controller in its class.

The Spa Power 600AC/BC uses a small circulation pump which runs 24 hours a day, to circulate water
through the filter and heater. The heater is always automatically controlled to maintain the water at the
desired temperature as set by the user

The user can leave the system to look after the spa

and know it will be at the correct temperature whenever he or she wants to use it.

(see below).

Temperature Control

Adjusting Set Temperature

UP

Increase the set temperature by 0.5 C per beep (Max = 41.5 C)

o

o

DOWN

Decrease the set temperature by 0.5 C per beep (Min = 10.0 C)

o

o

The Spa Power 600AC/BC gives the user direct control of the pool temperature from the poolside
control panel. Holding down the Up or Down button will adjust the temperature set point as shown on
the digital readout. There is a slight delay before the buttons operate to reduce the risk of accidental
adjustment. The pool temperature will be maintained very close to the set temperature.

The display normally shows the temperature set point, unless the optional in pool temperature sensor is
fitted in which case the sensed water temperature is displayed. In either case the temperature set point
will be displayed while being adjusted as described above.

Default Display

37.0

Non-Default Display Value

The non-default display value (either sensed water temperature or temperature set point) can be
checked if necessary by pressing the Up & Down buttons simultaneously.

H20

JET PUMP

HEATER

AIR

ON

SPA POWER 600

SPA POWER 600

37.0

Press both buttons
simultaneously

Page 1

Page 6

If the optional time clock has been fitted, sleep mode is used to disable
automatic temperature maintenance and filtration in order to reduce the heat
contribution from the small circulation pump and extend the small circulation
pump and (optional) ozone system life. The sleep time setting is done using the
digital time clock on the front of the control box (See below for setting
instructions). The spa will wake from sleep mode when any button is pushed to
allow it to be used manually as normal. If the spa is in use it will not enter sleep
mode until 30 minutes after the last manual button push, even if the clock is
calling for sleep mode. On wake up from sleep the system will run the Main
pump for 15 seconds and then the blower for 15 seconds to purge the plumbing.
This prevents any stagnant water from collecting in the pipes if the pool is not
used for an extended period.

To Set Current Time and Day

1. Press the

button before use. NOTE: This is optional. It will clear the current time and program settings.

2. Hold down the

button and press the

button until the correct day is selected. Release both buttons.

3. Hold down the

button and press the

button until the correct hour is set. Release both buttons.

4. Hold down the

button and press the

button until the correct minute is set. Release both buttons.

5. After setting the weekday and time, the seconds will reset automatically and the clock will begin keeping time.

RESET

CLOCK

DAY

CLOCK

HOUR

CLOCK

MIN

Sleep Time (Optional Timeclock)

To Set Programs

1.

Press the

button. "1ON" will appear at the left side of the display. This is the start time of the first programmed sleep

block (the time you want the spa to enter the sleep mode).

2.

Press the

button to select the days on which this sleep program will operate. There are 15 settings to choose from.

3.

Press the

button to set the hour of the desired time to enter sleep mode.

4.

Press the

button to set the minutes of the desired time to enter sleep mode.

5.

Now the start time has been set, press the

button again. "1OFF" will appear on the display. This is the end time of the first

programmed sleep block (the time you want the spa to resume normal operation).

6.

Repeat the same procedure (2 to 4 above) until the "1OFF" time is set.(

7.

Your timer gives you up to 8 different programmable periods. You can use all 8 settings , or as few as you like.

8.

To Review your set programs press the

button and keep pressing it to advance through each setting.

TIMER

DAY

HOUR

MIN

TIMER

TIMER

Be careful to set the same days as used in the "1ON" time).

IMPORTANT NOTE: The "MANUAL" button on the clock can be used to override the programmed sleep settings. It is very important to
ensure that the clock is set to "AUTO" so that the programmed times can operate. If the clock is manually set to ON then the pool will
stay in sleep mode and THE WATER WILL GO COLD. If it is left in "OFF" then the pool will not enter the sleep mode. The clock does
not return to "AUTO" by itself.

NOTE: If the “MANUAL” button on the clock is pushed the spa will not return to the programmed settings until the next
programmed time.

MANUAL

DAY

C

LO

C

K

TIM

ER

HO

UR

M

IN

P

ON

9:31

39

ON

AUTO

OFF

MON

ON

HE

AT

HEA

T

HE

AT

HEA

T

PU

MP

PUMP

AU

TO

AUT

O

AIR

AIR

PU

MP

PUMPAU

TO

AUT

O

AIR

AIR

37.0

Отзывы: