![Spa Electrics Retro Universal Series Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/spa-electrics/retro-universal-series/retro-universal-series_installation-and-owners-manual_1338766025.webp)
This device complies with part 15 of the FCC rules. Operation is subject to the
following two (2) conditions:
(1)
This device may not cause harmful interference, and
(2)
this device must accept any interference received, including interference that
may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different
to that to which the receiver is connected.
•
Consult the dealer or an experienced radio / TV technician for help.
Do not make any changes or modifications to the equipment
unless otherwise specified in the manual.
Underwriters Laboratories (UL) Statement
Per the NEC, NFPA 70, Article 680.23 (B)(5), states that bonding shall not
be required for luminaires that are listed for the application and have no
non-current carrying metal parts. In addition, per Article 680.26 (B)(4),
exception states that Listed low-voltage lighting systems with non-metallic
forming shells shall not require bonding.
Therefore, luminaires with polymeric/non-current carrying metal parts
are not required to be grounded / bonded.
Manufacturers Statement
Spa Electrics
Retro Universal
luminaires with their plastic housing designs
do not require grounding / bonding.
Spa Electrics
Retro Universal
lights have also been determined
to comply with the applicable requirements for wet-niche,
LED type Swimming Pool and Spa Luminaires.
FCC COMPLIANCE STATEMENT
ELECTRICAL GROUNDING
24
Содержание Retro Universal Series
Страница 1: ...POOL LIGHT UNIVERSAL INSTALLATION...
Страница 27: ...KEY DIMENSIONS 59 64 23 4mm 11 13 32 290mm diameter 26...