background image

7

Discharge of extract air:

Connected to the discharge duct to the outside

This duct must be well sealed and thermally insulated to avoid condensation
both on the inside and outside.

By-pass:

The 100% by-pass system of the ORKA allows the introduction of cooler fresh air (during the evenings 
and in the night) avoiding the heat exchanger and thus without it being tempered by the outgoing 
warm air which has accumulated in the house during the day.

Alarm fi lter change:

The unit has a timer “12 months TIMER” that alerts the user when to change the fi lters.

2.3. DIMENSIONAL CHARACTERISTICS

2.3a. Central

      

Weight: 20 kg

2.3b. Remote control

Содержание ORKA HR

Страница 1: ...ORKA HR EN ...

Страница 2: ......

Страница 3: ... mental capabilities or lack of experience and knowledge if they have been given supervision or instruc tion concerning use of the appliance in a safe way and understand the ha zards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision ...

Страница 4: ...ntrol of ORKA 6 Commissioning the ORKA 7 Maintenance 8 Putting out of service and recycling 9 ECODESIGN Technical sheet The following items are included 1 1 x ORKA HR 2 1 x remote control 3 1 x condensate drain tube support 4 3 x positioning accessories 5 3 x reductions Ø 125 160 6 4 x plug Ø80mm 7 1 x instruction manual ...

Страница 5: ...R has been designed to be incorporated into a ventilation system Following installation there should be no risk to safety health and the environment according to EC directives This also applies to other products used in the installation The following general guidelines are important Follow the safety instructions to prevent injuries and damage to the motorised fans The technical characteristics de...

Страница 6: ...t Fresh air from outside Discharge to outside Extraction of bathroom and kitchen Supply to living room and bedrooms Covers to filters access New fresh air inlet This spigot is to connect the supply duct of fresh air from outside Install the fresh air intake wall or roof a sufficient distance from any area of high pollution trees exhaust fumes road etc This duct must be sealed and insulated to preven...

Страница 7: ... of the ORKA allows the introduction of cooler fresh air during the evenings and in the night avoiding the heat exchanger and thus without it being tempered by the outgoing warm air which has accumulated in the house during the day Alarm filter change The unit has a timer 12 months TIMER that alerts the user when to change the filters 2 3 DIMENSIONAL CHARACTERISTICS 2 3a Central Weight 20 kg 2 3b Re...

Страница 8: ...mally isolated In areas that regularly have negative temperatures 2ºC a pre heating battery must be installed Operating temperature 2ºC 45ºC Ducts must be thermally insulated and correctly installed Uninsulated duct Insulated duct Insulated duct Spigot arrangement Ø 80 mm Spigots that are not used must be plugged with the supplied accessory ...

Страница 9: ...ories The condensate outlet that is not used must be plugged with the supplied plug The condensate tube must maintain the slope throughout its length Fix the duct if it is necessary Installation should have a siphon filled with water as indicated For correct maintenance a sufficiently large equipment access hatch must be installed Recommended Dimensions 1000 x 750 mm ...

Страница 10: ...accessory The condensate outlet that is not used must be plugged with the supplied plug The condensate tube must maintain the slope throughout its length Fix the duct if it is necessary Installation should have a siphon filled with water as indicated For correct maintenance access must be allowed to the equipment to each exposed side Access is from the top ...

Страница 11: ... sections and must be correctly stretched It is recommended not to put th RDR flow regulator on a branch both in extraction kitchen and in supply living room to take advantage of the peak flow activated by the remote control Kitchen Toilets Living room bedrooms BDO or TPM 80 CPR or CT 125 ...

Страница 12: ...must be correctly stretched It is recommended not to put th RDR flow regulator on a branch both in extraction kitchen and in supply living room to take advantage of the peak flow activated by the remote control Kitchen Toilets Living room bedrooms CPR or CT 125 BDO or TPM 80 BDO or BOAP 125 BDO or TPM 80 ...

Страница 13: ...hort sections and must be correctly stretched It is recommended not to put th RDR flow regulator on a branch both in extraction kitchen and in supply living room to take advantage of the peak flow activated by the remote control Kitchen Toilets Living room bedrooms CPR or CT 125 ...

Страница 14: ...ICS AND ELECTRICAL CONNECTION Power Single phase 230V 50Hz Max current 0 7 A Electrical protection 2 A curve C Max Power 145 W Maximum ambient temperature 50ºC Maximum flow temperature 45ºC Configuration A Configuration B ...

Страница 15: ...seconds during the first 4 days Subsequently the flashing will be every 30 seconds for the next 9 days When the filters have been changed the alarm must be reactivated by pressing the button for 5 seconds To check the remaining time until the end of the timing press the button for 3 seconds and the pilot light will illumi nate a number of times to the number of months remaining to reach 12 months To ...

Страница 16: ... the following process 1 Verify that all system components are correctly installed and connected Fresh air intake duct insulated and connected correctly Do not use a fresh air intake equipped with insect screen Fresh air and exhaust ducts insulated and connected correctly Fresh air and exhaust vents connected Flow regulators mounted in the right direction if installed Air outlet using insulated du...

Страница 17: ...s remove dust from inside of the heat recovery unit with a vacuum cleaner Every 6 months clean the extraction spigots of kitchen and bathroom with warm water and soap 8 PUTTING OUT OF SERVICE AND RECYCLING EEC legislation and our consideration of future generations mean that we should always recycle materials where possible please do not forget to deposit all packaging in the appropiate recycling ...

Страница 18: ...tor 1 Control typology Manual o Maximum internal leakage for BVU 4 Maximum external leakage for BVU and UVU 4 p Mixing rate for BVU without duct connection Not apply q Position of visual filter warning Remote control description of visual filter warning Pilot light r Instructions to install supply grilles Not apply Instructions to install exhaust grilles Not apply s Internet address www solerpalau c...

Страница 19: ......

Страница 20: ...S P SISTEMAS DE VENTILACIÓN S L U C Llevant 4 Polígono Industrial Llevant 08150 Parets del Vallès Barcelona España Tel 34 93 571 93 00 Fax 34 93 571 93 01 www solerpalau com Ref 9023090600 ...

Отзывы: