Charging Port 

Next to the on/off switch on the back of the light, underneath the rubberized protective 

cover, a USB-C charging socket is located. Pull the water-resistant cover up to expose the 

USB-C port. Plug the USB-C cable end into the light and the USB end into an appropriate 

USB port (e.g. Computer / Phone Charger/240v USB plug). While charging the process is 

symbolized by flashing green LED on the battery indicator.  When fully charged the Battery 

indicator LED will be illuminated solid green. 

 

Maintenance:              

  Fully charge the light before first use 

  Recharge after every use 

  When not in use recharge every 3 mouths  

  The lamp must not be switched on whilst being charged  

  Use only 5v / 1A charger to charge lamp  

 

Disposal & Recycling Information 

When the tool reaches its end of life, take it to a collection point designated by local 

Authorities for E-wast. The separate collection and recycling of your product at the time of 

disposal will help conserve natural resources and ensure that it is recycled in a manner 

that protects human, heath and the environment. 

 

 

 

 

 

• The safety features should be regularly checked for proper function

 

• The product must not be used, if damaged or defective in any way 

• Modification of the product is not allowed 

• Store in a safe place away from children and untrained personal 

• This Disinfection lamp is not a toy - store away from children  

• This Disinfection Light must be operated by adults only 

   NEVER look directly at the UV light while it is illuminated – doing so could temporarily or    

   chronically damage your eyesight or may even result in loss of vision. Failure to follow all    

   instructions listed may result in serious personal injury.  

• Use objects to block UV rays for example when disinfecting inside a car, keeping all the  

  windows up prevents UV-C rays escaping the vehicle as they cannot pass through the  

  glass of the vehicles windows. 

Short wave ultraviolet with wavelength 200~280nm (UVC,)  

  has the weakest penetration ability and cannot penetrate most transparent glass and  

  plastic products.  Quartz is an exception and reason this unit is fitted with a quartz lens.

 

• Avoid using on valuable 

 

• Always wear long sleeved cloths to cover bare skin 

• Always wear Glasses with glass or resin lenses 

• Always wear gloves to cover hands 

• Most importantly, make sure people, pets and plants  

  cannot be exposed to UV rays during sterilization.  

• The warnings, cautions and instructions discussed in   

   this instruction manual cannot cover all possible  

   conditions and situations that may occur. The operator must exercise common sense  

   and caution when using this UV-C Disinfection lamp. 

 

 

Содержание SP81479

Страница 1: ...AND ATTACH RECEIPT TO MANUAL FOR FUTURE REFERENCE NOTE Proof of purchase must be retained by the customer as it will be required in the event of a claim under warranty AFTER SALES SUPPORT AUSTRALIA Vi...

Страница 2: ...uction 3 Intended Use 3 Scope of Delivery 3 Technical data 4 Safety Symbols 4 Warning 5 Operating Instructions 7 Charging Process 9 Maintenance 9 Disposal Recycling Information 9 Training Record 10 Wa...

Страница 3: ...contents of this manual and must strictly observe the instructions therein The user of the product is always fully responsible for its safe use and application Observe all safety instructions and regu...

Страница 4: ...LED s Beam Angle 120 Charging Time 4 5 hours approx Battery Lithium ion 3 7v 4400mAh Charge Voltage Current 5v 1000mA Charging Cable USB USB C Water Resistant IP65 Operating Temperature 10 C 40 C Dim...

Страница 5: ...emissions are divided into 3 main groups UV A rays have the least energy among UV rays These rays can cause skin cells to age and can cause some indirect damage to cells DNA UV A rays are mainly linke...

Страница 6: ...n OFF turns UV rays off when movement is detected during fixed mode operation Kills 99 9 of pathogens such as bacteria viruses and protozoa Visible violet light provides visible confirmation of when U...

Страница 7: ...ure to overlay each track slightly Be aware that the UV rays will be extinguished if the unit is moved more than 3cm away from the surface This is a safety measure to prevent accidental exposure and e...

Страница 8: ...Work Light Mode Press the power switch once for white light and the unit can be used as a normal work light Press the power switch again to turn off UV C Test Mode Used to turn on UV C emitters only...

Страница 9: ...Modification of the product is not allowed Store in a safe place away from children and untrained personal This Disinfection lamp is not a toy store away from children This Disinfection Light must be...

Страница 10: ...as detailed in this manual Date of Training Name Signature Always wear gloves to cover hands Always wear glasses with glass or resin lenses Always wear long sleeved cloths to cover bare skin Most impo...

Страница 11: ...or normal wear and tear 1 2 Has been used in a manner other than for which it was originally designed 1 3 Has been tampered with or is otherwise than as supplied by SP Tools 1 4 Where any damage malfu...

Отзывы: