6
Stage 7 – “Float”
This stage will “even out” the voltage between all cells maintaining a constant voltage with
a reduced current, thus prolonging the battery service time. If a load is applied to the battery
and the battery voltage drops below 12.4 volts, the charger will restart from the absorption
stage.
Stage 8 – “Maintain”
This final stage regulates the fully charged battery. A small pulse charge is applied at 0.5Hz
to maintain the battery at its fully charged state and ready to be used at any time. If a load
is applied to the battery and the battery voltage drops below 12.4 volts, the charger will
restart from the absorption stage.
Safety Instructions for Charger & Battery
1. Do not use a damaged appliance. If the
electrical cord is damaged have it
repaired or replaced by a qualified
electrician immediately.
2. Explosive gases may escape from the
battery during charging.
3. Do not charge inside a box or container of any kind. The battery must be placed in a
well-ventilated area during charging.
4. Prevent flames and sparks - ensure the area is well ventilated.
5. Do not short the battery or touch the terminals with any conductive materials.
6. Do not expose battery charger to water or rain, make sure you have dry hands when
operating the charger.
7. Before charging ensure you have read the instruction manual in full.
8. This charger is for use indoors, do not expose to rain or excessive dust.
9. Be careful not to drop, shake or strike the charger or battery.
10. Disconnect from 240Volt supply before making or disconnecting connections to the
battery.
11. This charger is for charging 12volt batteries only
12. This appliance is not for use with non-rechargeable batteries.
13. Never charge a frozen battery.
△
!
△
!
WARNING