X. Troubleshooting cont’d
The PixiePlus does not control the projector/monitor.
Be sure that the code was programmed correctly – try reprogramming the unit.
Confirm that the IR emitter bud is positioned directly over the receiver on the IR win-
dow of the device you are controlling. Some devices are sensitive to accurate
placement.
Fluorescent lights can interfere with IR signals. Check if the projector is close to a
fluorescent light source. If so, try turning off the lights. If this restores control, cover
the IR emitter bud and display device IR receiver window with an IR-opaque shield,
such as gaffer's tape. Some opaque tapes do not block IR.
The device will not switch to one of the inputs.
Some display devices will not switch to certain inputs if there is no signal present
Control is intermittent.
If you are using a device manufactured by Philips, Magnavox, or Koss, please con-
sult the SP Controls PXE-DCM Philips Protocol Application Note for additional pro-
gramming instructions.
If you are still unable to control your device, please contact SP Controls Technical
Support for further assistance.
XI. Technical Specifications
The PixiePlus is
UL listed
and
CE certified
.
Package Type
Dimensions
Weight (PCB with bezel and 3
insert modules)
Power Supply
Output Type
Recommended Wire
Single-Gang Decora™ Mounting
4.130” (h) x 1.745” (w) x .90” (d)
2.5 oz
6VDC, 300mA
IR Emitter/RS-232 (programming RS232
commands requires PXE-PGM-TOOL, sold
separately)
18- to 22- Gauge 3-conductor stranded copper
wire