ELECTRICAL CONNECTION
This work must be carried out by a licensed electrician.
All 3 phase compressor are not supplied with a power lead or plug. A licensed electrician is required to wire up the
compressor from the wall mounted contactor box, to a dedicated 3 phase electrical outlet, either with a four pin plug or
hard-wired into the electrical supply. The circuit must be of adequate capacity and fitted with a circuit breaker.
Mount the contactor box to the wall as close to the compressor as practical.
Ensure correct direction of rotation
:
The installing electrician must ensure that when wired in, the motor
is turning in the correct direction. Failure to obtain the correct
direction of rotation will prevent the fan / flywheel from delivering
the necessary air cooling across the pump.
Electrical Connection
All electrical installation and service work must be performed by a licensed electrician in accordance with all applicable
regulations. The electric motor rating as shown on the motor nameplate and the power supply must have compatible
voltage, phase and frequency characteristics.
The required size of electrical wiring between the power supply and the electric motor varies according to motor power
and other factors, use the table below to understand what power is required to operate each size Compressor.
Adequately sized wiring must be installed to protect against excessive voltage drop during compressor start-up and
running. If connecting other electrical equipment to the same circuit, consider the total electrical load when selecting
the proper wire size. Overheating, short circuiting and fire damage may result from undersize wiring.
NB
Portable electric generators are not recommended for operating compressors unless they have ample generating
capacity to provide the requisite starting and running currents without appreciable voltage or frequency drop.
Model:
XRS25
Piston Compressor
50% duty cycle
453L/PM
10 Bar
(150 psi)
5.5 HP
(4 KW)
415V
(3 Phase)
8AMPS
(per Phase)
200 L
XRS35
Piston Compressor
50% duty cycle
708L/PM
10 Bar
(150 psi)
7.5 HP
(5.6 KW)
415V
(3 Phase)
10AMPS
(per phase)
270 L
XRS50
Piston Compressor
50% duty cycle
1132L/PM
10 Bar
(150 psi)
10HP
(7.46 KW)
415V
(3 Phase)
13.5AMPS
(per phase)
270 L