BMK-8 U / BMK-12 W
31
Explanation of parameters
• Piston
This parameter serves to adjust the post-blow time of the stud feed blow air beyond the standard
measure when the pushing piston in the welding gun/welding head has moved forward to press the
stud out of the stud holder. A longer time setting is required when welding e.g. above the head to
achieve a trouble-free stud reload. The post-blow time can be set between 100 ms and 2000 ms.
• Ready (only possible with "Feeder BMK" function in conjunction with a BMK feeder)
With UVR-300 feeder: This parameter serves to adjust the waiting period of the
hexagonal barrel in the feeding position with simultaneous post-vibration of studs.
Depending on the type of feeder, a basic setting between 500ms and 1000ms is
recommended.
With UVR-250 feeder: This parameter serves to adjust the after-run period of the
feeder when the light barrier has detected a stud in the stud escapement.
• Cont. (only possible with "Feeder BMK" function in conjunction with a BMK feeder)
This parameter serves to adjust the post-vibration period of the feeder to fill the outlet rail
when a stud has been brought in blow-off position. The after-vibration period can be set
between 100ms and 2000ms.
• BlAir
This parameter serves to adjust the delay time of the stud feed blow air after the injection
piston in the welding gun/welding head has moved back. After the set delay time, the stud
feed blow air is activated. This is necessary e.g. in the case of a short stud feed hose. The
delay time can be set between 100ms and 2000ms.
• Feeder (RUT)
This parameter serves to adjust the feeder type connected. UVRBMS and UVRBMK can be
set as feeder types.
R
5.3.4
Special function "Selection of language. Display of software version number"
This special function serves to select different languages and to display the version number of the
software. The languages available are indicated on the display.
For calling this function, please proceed as follows:
• Simultaneously press the "arrow up" and "arrow right" keys and keep them pressed.
• Switch stud welder on with main switch.
• Stop pressing the function keys.
• Follow the instructions on the display.