Soyal AR-837-E Скачать руководство пользователя страница 6

V200929

   

LCD / Biometrics Access Controller 

O. Alarm Clock (for Factory)

Hardware installation

M1

Board

Horn

M2

1

2

3

4

5

6

7

8

N.C.

N.O.

COM

CTL

12V

ALM

12V

GND

GND

P1

Output to 

M1

 and 

M2

Mike device

Mike device

Music Box

Music Box

Mike's sound wire

Mike's sound wire

DC 12V Relay Board

Controller 

POWER

12VDC

Access programming mode

 →     

Tools

 →     

Daily Alarm

 → 

Set (00~15) 

→ 

Set Start Tm (24 Hours)

 

;

 

Set Effect Sec. 

(Seconds as the bell time, Range:1~255)

 

→ 

Set Weekday (0:disable, 1: enable) 

→ 

Succeeded

  

5

9

N. Lift control

[e.g.] Connect with 

AR-401RO16B

 to control which floor the user will be able to access. (BAUD9600)

Access programming mode

 →     

Tools

 →    

 Terminal Port

 → 

0

Lift Controller 

→ 

Baud Selection 0

: 

9600

5

4

Setting Lift control

Access programming mode

 →     

User Setting

 →    

 Single Floor

 →

Input 5-digit user address

 → 

Input single floor number: 1~64

2

4

Single floor

Access programming mode

 →     

User Setting

 →    

 Multi Floor

 → 

Input 5-digit user address

 → 

Select range: 1 or 2 or 3 or 4

 → 

Input 16 digits 

multi floors number [0:disable, 1: enable]

[e.g.] Set NO. 114, can use it through the 8 F and 16F:

       

Access programming mode

 →     

User Setting

 →    

 Multi Floor

 → 

114

     

 

→ 

1     

 

→ 

0000000100000001

           

2

2

5

5

Multi floors

Set Floor/ Stop

1

0

17

0

33

0

49

0

9

0

25

0

41

0

57

0

1

2

3

4

3

0

19

0

35

0

51

0

11

0

27

0

43

0

59

0

2

0

18

0

34

0

50

0

10

0

26

0

42

0

58

0

4

0

20

0

36

0

52

0

12

0

28

0

44

0

60

0

5

0

21

0

37

0

53

0

13

0

29

0

45

0

61

0

6

0

22

0

38

0

54

0

14

0

30

0

46

0

62

0

7

0

23

0

39

0

55

0

15

0

31

0

47

0

63

0

8

1

24

0

40

0

56

0

16

1

32

0

48

0

64

0

Access programming mode

 →     

Tools

 →    

 Terminal Port

 → 

1

Lift Controller

(

need to use 725L485

)

5

5

While connecting with AR-721-U, AR-737-H/U(WG mode) and AR-661-U for anti-pass-back function, the access mode must be "Card" only.

M. Anti-pass-back

Device enable

Access programming mode

 →   

 

 

Parameters[2]

 →     

Anti-pass-back

 → 

master controller select [1: Yes] 

→ 

WG select [1: Yes]

4

6

Card user enable

Access programming mode

 →   

 

 

Add/ Delete

 →     

Antipass Group

 → 

Input 5-digit starting user address

 → 

Input 5-digit ending user 

address

 → 

must select [1: Yes]

1

9

Enable/Disable the arming status:

Standby Mode

Access Programming mode

Card only

Card or PIN

Card and PIN

Open the door
Present the tag to reader

 → 

Input 

4-digit arming PWD

 →

Input user address

 → 

Input 

4-digit individual PWD

 →      → 

Input 4-digit arming PWD

 →

Present the tag to reader

 → 

Input 

4-digit individual PWD

 →      → 

Input 4-digit arming PWD

 →

Enable:

 Access programming mode

 →     

Quit & Arming

7

Disable:

 Access programming mode

 →     

Quit

6

No open the door

     → 

Input 4-digit arming PWD

 

→ 

Present the tag to reader

※ 

[Use FP] can substitute for [Induct valid card].

Содержание AR-837-E

Страница 1: ...Cable WireApplication Wire Color Description Door Bell 1 Black White Transistor Output Max 12V 100mA Open Collector Active Low 2 Black DC 0V Cable WireApplication Wire Color Description Beeper 1 Pink...

Страница 2: ...lue Cable Cable Cable WireApplication Wire Color Description 1 2 TCP IP Output 3 Orange White Net TX 4 Orange Net TX 5 Green White Net RX 6 Gerrn Net RX 7 CN7 CN9 CN10 Connect to Electric Strike Conne...

Страница 3: ...ess programming mode Tools Language EN Succeeded Initial system 5 1 0 N C N O COM 12V E BZ RLED GLED WG 0 WG 1 12V GND 12V GND Exit Switch 12V GND BZ RLED GLED Door Output WG 0 WG 1 WG DS WG PB EXI EX...

Страница 4: ...perating in Programming Mode or flashing an existed card in card learn mode it comes 2 beeps warning and LCD panel displays Same Card user address card number Error red invalid card with 2 beeps warni...

Страница 5: ...The AR 837EF 9000DO needs to collect twice for each fingerprint however AR 837EF 1500DO needs to collect three times for each fingerprint 2 6 Deleting Access programming mode User Setting Delete FP K...

Страница 6: ...17 0 33 0 49 0 9 0 25 0 41 0 57 0 1 2 3 4 3 0 19 0 35 0 51 0 11 0 27 0 43 0 59 0 2 0 18 0 34 0 50 0 10 0 26 0 42 0 58 0 4 0 20 0 36 0 52 0 12 0 28 0 44 0 60 0 5 0 21 0 37 0 53 0 13 0 29 0 45 0 61 0 6...

Страница 7: ...ISP Firmware 1 Input the Target Address and Port 2 Load F W open the documents that have the new ISP Firmware 3 Click the new ISP Firmware and Open it 4 Click Update F W to start the firmware update...

Страница 8: ...Ethernet Module device Please alter the IP address as you want and then click Update button After updating the IP please re connect the Web Browser by the new IP address User Password The password is...

Отзывы: