V110713
Access Controller
Command List
Function
Command
Description
Mode
Entering programming mode
PPPPPP
PPPPPP=Master Code, default value=
123456
M4/M6/M8
Exiting programming mode
M4/M6/M8
Exiting programming mode and enabling arming status
M4/M8
Node ID setting
(Connecting to 716E
00 NNN
NNN=Node ID
,
range: 001~254
M4/M8
Node ID setting
(Connecting to PC directly without
via 716E)
00 NNN VVV nnn
NNN=Node ID of Access Controller, VVV=Virtual 716E Node ID,
nnn=Door number; range:001~254
M4/M8
Mifare tag / card format
(Optional)
01 N
N: 0=ISO14443A;
1=ISO14443B; 2=ISO15693;
3=I Code1; 4=I Code2
PS.1. Please select the compliance,first.
2. Make sure reader and card using the same compliance.
M4/M8
Door relay time setting
02 TTT
TTT=Door relay time
000= Output constantly
001~600=1~600 sec.
601~609=0.1~0.9 sec.
M4/M6/M8
Alarm relay time setting
03 TTT
TTT=Alarm relay time
000= Output constantly 001~600=1~600 sec.
M4/M6/M8
Control mode setting
04 N
N=Mode
4=Mode4
;
6=Mode6; 8=Mode8
M4/M6/M8
Arming delay time setting
05 TTT
TTT=Alarm relay time
001~600=1~600 sec.
M4/M6/M8
Alarm delay time setting
06 TTT
TTT=Alarm delay time
001~600=1~600 sec.
M4/M6/M8
Master card setting
07 SSSSS EEEEE
SSSSS-EEEEE=00000-01023 (00000-03000 for AR-725H);
SSSSS=Starting user address; EEEEE=Ending user address
M4/M8
Auto-open time zone setting
08 N HHMMhhmm 7123456H
N= 0(1st time zone) / 1(2nd time zone)
HHMM= Starting time; hhmm= ending time
(i.e.: 08301200=08:30 to 12:00)
7123456H= 7 days of week (Sun/Mon/Tue/Wed/Thu/Fri/Sat)+ Holiday
(H= 0: disable; 1: enable); Holidays establish by the software.
M4/M6/M8
Master code setting
09 PPPPPPRRRRRR
PPPPPP=New master code
RRRRRR=Repeat the new master code
M4/M6/M8
Setting
Suspend tag(M6)
10 SSSSS EEEEE
=Suspend =Delete;
SSSSS=Starting user address, EEEEE=Ending user address
M4/M6/M8
Delete tag(M4)
10 SSSSS EEEEE
M6
Set a sequence of cards as "read and access"
11 SSSSS EEEEE
SSSSS=Starting card number
;
EEEEE=Ending card number
M4/M8
Active the suspended cards
11 SSSSS EEEEE
SSSSS=Starting user address
;
EEEEE=Ending user address
M4/M8
Set the cards as Card mode OR PIN mode by user
address
12 UUUUU PPPP
Access mode:
Card or PIN
; UUUUU=user address;
PPPP=4-digit pass code 0001~9999
M4/M8
Set the cards as Card AND PIN mode by user
address
13 UUUUU PPPP
Access mode:
Card and PIN
; UUUUU=user address;
PPPP=4-digit pass code 0001~9999
M4/M6/M8
M4: Duress code setting
M6: Public PIN setting
(Card or PIN)
15 PPPP
PPPP=4-digit pass code (default value=
4321
)
P.S. Duress code will be unavailable and become a public PIN at access mode “
Card or PIN
” of
M6
M4/M8
Card number modification
16 UUUUU SSSSSCCCCC
UUUUU= User address; SSSSS=5-digit site code;
CCCCC=5-digit card code
M4/M6/M8
M4: Arming pass code setting
M6: Public PIN setting
(Card and PIN)
17 PPPP
PPPP=4-digit pass code ( default value=
1234
; disable Arming PWD=
0000
)
P.S. Arming PWD code will be unavailable and become a public PIN at access mode “
Card PIN
” and of
M6
M4/M6/M8
Door open waiting time
18 TTT
TTT=Door open waiting time: 001~600=1~600 sec.; default value: 15 sec.
M4/M8
Set the card by induction
19 UUUUU QQQQQ
UUUUU=User address;
QQQQQ=Card quantity(
00001
=Continuously inducting)
M4/M6/M8
Reader additional setting
20 DDD
Please refer to function default value for details.
M4/M6/M8
Lift control setting: multi-doors
21 UUUUU S FFFFFFFF
UUUUU=User address, S=4 sets of lift control(0~3); FFFFFFFF=8 assigned floor
(F=0: Disable, 1: Enable)
M4/M8
Add/Delete tag by induction
(M6 only)
22 N
N=0(Delete tag); N=1(Add tag)
M6
AR-401ROsite number dip switch
23 NNN TTT
NNN=site number, TTT= relay time: 000~600=1~600 sec.
M4/M8
Controller parameter setting
24 DDD
Please refer to function default value for details.
M4/M6/M8
Controller time clock setting
25 YYMMDDHHmmss
YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec.
M4/M6/M8
Anti-pass-back
(Enable user)
26 SSSSS EEEEE N
SSSSS=Starting user address; EEEEE=Ending user address;
N=0/Enable; N=1/Disable; N=2/Initial
M4/M8
Single floor setting
27 UUUUU FF
UUUUU=User Address; FF=Floor (01~32 floor)
M4/M8
Dual door control/ Active or inactive arming for force open
28 DDD
Please refer to function default value for details.
M4/M6/M8
Delete all tags
29 29
M4/M6/M8
Enable the security trigger signal ( with AR-721RB)
34 064
(Enable)
34 000
(Disable)
To Change the "Door Lock" become the security trigger signal, when
controller is connected with AR-721RB.
M4/M6/M8
9