Soyal AR-723H Скачать руководство пользователя страница 4

V110713

   

Access Controller

Command List

Function

Command

Description

Mode

Entering programming mode

     PPPPPP

PPPPPP=Master Code, default value=

123456

M4/M6/M8 

Exiting programming mode

M4/M6/M8

Exiting programming mode and enabling arming status

M4/M8

Node ID setting

 (Connecting to 716E

00     NNN

NNN=Node ID

range: 001~254

M4/M8

Node ID setting

 (Connecting to PC directly without 

via 716E)

00     NNN     VVV     nnn

NNN=Node ID of Access Controller, VVV=Virtual 716E Node ID, 

nnn=Door number;      range:001~254

M4/M8

Mifare tag / card format

 (Optional)

01     N

N: 0=ISO14443A;

 

1=ISO14443B; 2=ISO15693;

     3=I Code1; 4=I Code2

PS.1. Please select the compliance,first. 

      2. Make sure reader and card using the same compliance.

M4/M8

Door relay time setting

02     TTT

TTT=Door relay time

  

000= Output constantly

                                     001~600=1~600 sec.

                                     601~609=0.1~0.9 sec.

M4/M6/M8

Alarm relay time setting

03     TTT

TTT=Alarm relay time

  

000= Output constantly  001~600=1~600 sec.

M4/M6/M8

Control mode setting

04     N

N=Mode

 

4=Mode4

6=Mode6; 8=Mode8

M4/M6/M8

Arming delay time setting

05     TTT

TTT=Alarm relay time

  

001~600=1~600 sec.

M4/M6/M8

Alarm delay time setting

06     TTT

TTT=Alarm delay time

  

001~600=1~600 sec.

M4/M6/M8

Master card setting

07     SSSSS     EEEEE

SSSSS-EEEEE=00000-01023 (00000-03000 for AR-725H);

SSSSS=Starting user address; EEEEE=Ending user address

M4/M8

Auto-open time zone setting

08     N     HHMMhhmm     7123456H

N= 0(1st time zone) / 1(2nd time zone)

HHMM= Starting time; hhmm= ending time

(i.e.: 08301200=08:30 to 12:00)

7123456H= 7 days of week (Sun/Mon/Tue/Wed/Thu/Fri/Sat)+ Holiday

(H= 0: disable; 1: enable); Holidays establish by the software. 

M4/M6/M8

Master code setting

09     PPPPPPRRRRRR

PPPPPP=New master code

RRRRRR=Repeat the new master code

M4/M6/M8

Setting

Suspend tag(M6)

10     SSSSS     EEEEE

      =Suspend        =Delete;

SSSSS=Starting user address, EEEEE=Ending user address

M4/M6/M8

Delete tag(M4)

10     SSSSS     EEEEE

M6

Set a sequence of cards as "read and access"

11     SSSSS     EEEEE

SSSSS=Starting card number

EEEEE=Ending card number

M4/M8

Active the suspended cards

11     SSSSS     EEEEE

SSSSS=Starting user address

EEEEE=Ending user address

M4/M8

Set the cards as Card mode OR PIN mode by user 
address

12     UUUUU     PPPP

Access mode: 

Card or PIN

; UUUUU=user address;

                                          PPPP=4-digit pass code 0001~9999

M4/M8

Set  the  cards  as  Card  AND  PIN  mode  by  user 
address

13     UUUUU     PPPP

Access mode: 

Card and PIN

; UUUUU=user address;

                                             PPPP=4-digit pass code 0001~9999

M4/M6/M8

M4: Duress code setting 
M6: Public PIN setting

 (Card or PIN)

15     PPPP

PPPP=4-digit pass code (default value=

4321

P.S. Duress code will be unavailable and become a public PIN at access mode “

Card or PIN

” of 

M6

M4/M8

Card number modification

16     UUUUU     SSSSSCCCCC

UUUUU= User address; SSSSS=5-digit site code;

CCCCC=5-digit card code

M4/M6/M8

M4: Arming pass code setting
M6: Public PIN setting

 (Card and PIN)

17     PPPP

PPPP=4-digit pass code ( default value=

1234

; disable Arming PWD=

0000

)

P.S. Arming PWD code will be unavailable and become a public PIN at access mode “

Card  PIN

” and of 

M6

M4/M6/M8

Door open waiting time

18     TTT

TTT=Door open waiting time: 001~600=1~600 sec.; default value: 15 sec. 

M4/M8

Set the card by induction

19     UUUUU     QQQQQ

UUUUU=User address;

QQQQQ=Card quantity(

00001

=Continuously inducting)

M4/M6/M8

Reader additional setting

20     DDD

Please refer to function default value for details.

M4/M6/M8

Lift control setting: multi-doors

21     UUUUU     S     FFFFFFFF

UUUUU=User address, S=4 sets of lift control(0~3); FFFFFFFF=8 assigned floor

(F=0: Disable, 1: Enable)

M4/M8

Add/Delete tag by induction

 (M6 only)

22     N

N=0(Delete tag); N=1(Add tag)

M6

AR-401ROsite number dip switch

23     NNN     TTT

NNN=site number, TTT= relay time: 000~600=1~600 sec.

M4/M8

Controller parameter setting

24     DDD

Please refer to function default value for details.

M4/M6/M8

Controller time clock setting

25     YYMMDDHHmmss

YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec.

M4/M6/M8

Anti-pass-back

 (Enable user)

26     SSSSS     EEEEE     N

SSSSS=Starting user address; EEEEE=Ending user address;

N=0/Enable; N=1/Disable; N=2/Initial

M4/M8

Single floor setting

27     UUUUU     FF

UUUUU=User Address; FF=Floor (01~32 floor)

M4/M8

Dual door control/ Active or inactive arming for force open

28     DDD

Please refer to function default value for details.

M4/M6/M8

Delete all tags

29     29

M4/M6/M8

Enable the security trigger signal ( with AR-721RB)

34     064      

(Enable)

34     000      

(Disable)

To Change the "Door Lock" become the security trigger signal, when 

controller is  connected with AR-721RB.

M4/M6/M8

9