About Master Card

Enter the program mode

Input      123456      or      PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input  

   

876112

     → 

program mode accessed

Exit the program mode

Input

Operation process

M4/M8: Individual pass code

Card or PIN:

 

Access programming mode

 → 

12     UUUUU     PPPP       [e.g. User address: 00001 and pass code: 1234, input 12     00001     1234     ]

Card and PIN:

 

Access programming mode

 → 

13     UUUUU     PPPP       [e.g. User address: 00001 and pass code: 1234, input 13     00001     1234     ]

M6: Public pass word
Card or PIN:

 

Access programming mode

 → 

15     PPPP       [Input 4-digit pass code, default value: 4321]

Card and PIN:

 

Access programming mode

 → 

17     PPPP       [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]

Enable controller

Access programming mode

 → 

20     DDD       [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Access/Exit(0=Exit; 1=Access).]

         Access programming mode

 → 

20     128      (Please refer to function default value for details.)

[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128

Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need 

access and exit monitor.

C. Anti-pass-back(M4/M8)

B. Set up the password 

[Only for connect to external K-series reader]

Master Code modification

Access programming mode

 → 

09     PPPPPPRRRRRR         [Input the 6-digit new master code twice.]

[e.g.] Set the Master code to be 876112, input  

   

123456

     → 

09     876112876112

A. Enter/ Exit Program Mode

Adding Tag

Present Master Card

Deleting All Tags

Present Master Card

P.S. Once MASTER CARD is presented after one 

        warning beep, all card data will be cleared.

After 3 short beeps

[Access programming mode]

After 3  short beeps

[Access programming mode]

Present one new card at a time

1 long warning beep after 2sec.

Present Master Card

[Exit programming mode]

5 short beeps after 5sec: cards cleared

1.

1.

2.

2.

3.

3.

4.

4.

MASTER CARD Setting for Stand-Alone

Use the MASTER CARD software

Input the MASTER CARD number, and press [Write].

Cut off and then transmit the power, the master card number will be activated.

Present the card, and the reader will flash green light 3 times and sound 3 beeps. Then the card becomes MASTER CARD and accesses programming 

mode.If MASTER CARD is presented again, it will exit programming  mode.

Black

Orange

White

Yellow

Converter

Red

[e.g.] No. 154 enable the anti-pass-back, and induction into the door has not been induced to leave. When he represent into the door will become 
         invalid , then he needs to set the reset.  Access programming mode

 → 

26     00154     00154     2     

 → 

Reset

[e.g.] User address from 00152 to 00684 enable the anti-pass-back function:

 

26     00152     00684     0

Enable card

Access programming mode

 → 

26     SSSSS     EEEEE     N      

[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]

D. Lift control

Enable

Access programming mode

 → 

24     002       [002= enable lift control]

Connect with 

AR-401RO16B

 to control floors which the user will be able to access.

Plug in       cable instead of       cable, the wire connection is as below figure. After connection, then have power transmission to controller.

P4