Soyal AR-716E Скачать руководство пользователя страница 2

c. Go “My Network Places” → Click right of mouse “Properties” → Local Area 

    Connection → Click right of mouse “Properties” → Click “Internet  

    Protocol (TCP/IP)” twice to open its properties

d. Select “Use the following IP address” and key-in 

           

IP address: 192.168.001.64  (Assumed original IP:156.137.86.8)

              Subnet mask: 255.255.255.0

      →“OK ” to exit

e. Switch both DIP-SW 1 and DIP-SW 2 to “OFF”

f .  Install “Device Tools.exe”, and then run the Net727 

     software

g. Click “Get” to get TCP/IP module’s default local IP address, 

     gateway, netmask and TCP port.

h. Change new IP address, gateway, netmask and TCP port 

     instead of default values

 i.  Click “ Write ” to change the data

Write

h.

g.

i.

v070604

Setting

Notes

Defines own IP Address of the 

TCP/IP module
Defines the IP Address of the default 

gateway
Defines the IP Address range for the 

local network segment
The TCP port that o 

use to contact this device. To avoid 

conflicts with standard TCP ports.
The MAC (Media Access Control) 

address is a unique identifier set 

at the factory.
Forces TCP/IP       

time into the same data frame.
Defines the amount of data in the 

serial, Ethernet buffer at which the 

break condition will be generated 

and the contents of buffer will be 

sent out via the Ethernet port.

Allows contact with only the specified 

remote IP address.
To avoid the hacker use this IP to 

intercept data when Remote IP 

Address doesn’t receive data.
Console password
Changes current baud rate of the  

TCP/IP module’s serial port (from 

2400bps to 57600bps).
This device automatically closes TCP 

connection if there is no TCP activity 

for the given time.
An exchange of signal over specific 

wires which each device indicates its 

readiness to send or receive data.

Selecting the enable option allows 

DHCP to automatically assign the  

TCP/IP module’s IP address.

Local IP Address
Local Gateway 

IP Address

Local Subnet Mask 

TCP Port

MAC Address

Force Transmit time

Force Transmit 

Bytes

Lock Remote IP 

Address
Lock Serial Port

(Free Run or 

Freeze Over)
Setup Password

Serial Port Speed

TCP Auto 

Disconnect 

Time (Second)
Serial Port Hardware 

Handshaking 

(RTS/CTS)

DHCP

Value

192.168.001.127

192.168.001.254

255.255.255.000

1621

00.E0.4C.00.00.50

5

32

-

-

-

-

none

9600

60

TCP/IP Module Specification

2

AR-716E

SOYAL

j.Please chang yau PC IP back to 156.137.86.8 
  or tick Obtain an IP address automatically at 
  Internet Protocol (TCP/IP) Properties