![Soyal AR-716E Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/soyal/ar-716e/ar-716e_user-manual_1338208002.webp)
c. Go “My Network Places” → Click right of mouse “Properties” → Local Area
Connection → Click right of mouse “Properties” → Click “Internet
Protocol (TCP/IP)” twice to open its properties
d. Select “Use the following IP address” and key-in
IP address: 192.168.001.64 (Assumed original IP:156.137.86.8)
Subnet mask: 255.255.255.0
→“OK ” to exit
e. Switch both DIP-SW 1 and DIP-SW 2 to “OFF”
f . Install “Device Tools.exe”, and then run the Net727
software
g. Click “Get” to get TCP/IP module’s default local IP address,
gateway, netmask and TCP port.
h. Change new IP address, gateway, netmask and TCP port
instead of default values
i. Click “ Write ” to change the data
Write
h.
g.
i.
v070604
Setting
Notes
Defines own IP Address of the
TCP/IP module
Defines the IP Address of the default
gateway
Defines the IP Address range for the
local network segment
The TCP port that o
use to contact this device. To avoid
conflicts with standard TCP ports.
The MAC (Media Access Control)
address is a unique identifier set
at the factory.
Forces TCP/IP
time into the same data frame.
Defines the amount of data in the
serial, Ethernet buffer at which the
break condition will be generated
and the contents of buffer will be
sent out via the Ethernet port.
Allows contact with only the specified
remote IP address.
To avoid the hacker use this IP to
intercept data when Remote IP
Address doesn’t receive data.
Console password
Changes current baud rate of the
TCP/IP module’s serial port (from
2400bps to 57600bps).
This device automatically closes TCP
connection if there is no TCP activity
for the given time.
An exchange of signal over specific
wires which each device indicates its
readiness to send or receive data.
Selecting the enable option allows
DHCP to automatically assign the
TCP/IP module’s IP address.
Local IP Address
Local Gateway
IP Address
Local Subnet Mask
TCP Port
MAC Address
Force Transmit time
Force Transmit
Bytes
Lock Remote IP
Address
Lock Serial Port
(Free Run or
Freeze Over)
Setup Password
Serial Port Speed
TCP Auto
Disconnect
Time (Second)
Serial Port Hardware
Handshaking
(RTS/CTS)
DHCP
Value
192.168.001.127
192.168.001.254
255.255.255.000
1621
00.E0.4C.00.00.50
5
32
-
-
-
-
none
9600
60
TCP/IP Module Specification
2
AR-716E
SOYAL
j.Please chang yau PC IP back to 156.137.86.8
or tick Obtain an IP address automatically at
Internet Protocol (TCP/IP) Properties