V091021
LCD Access Controller
Metal Case / Standard
Access programming mode
→
Add/Delete
→
Antipass Group
→
Input Start address
→
Input End address
→
1: Yes; 2: No;(select one)
1
9
Card set-up
Usually, anti-pass-back is commonly applied to parking lots in order to prevent from multi-entry with one card, requires to set bith card and
device as the flowings:
E. Anti-pass-back(M4/M8 only)
Device set-up
Access programming mode
→
Parameters[2]
→
Anti-pass-back
→
1: Yes; 2: No;(select one)
→
1: In; 2: Out;(select one)
4
7
F. Lift control
Connect with
AR-401RO16B
to control which floors the user will be able to access.
Set Floor
1
0
17
0
9
0
25
0
1
2
3
0
19
0
11
0
27
0
2
0
18
0
10
0
26
0
4
0
20
0
12
0
28
0
5
0
21
0
13
0
29
0
6
0
22
0
14
0
30
0
7
0
23
0
15
0
31
0
8
1
24
0
16
1
32
0
Access programming mode
→
Tools
→
Termingal Port
→
1
:
AR-401RO16
5
4
Setting Lift control
Access programming mode
→
User Setting
→
Single Floor
→
Input 5-digit user address
→
Input single floor number: 1~32
2
4
Single floor set-up
Access programming mode
→
User Setting
→
Single Floor
→
Input 5-digit user address
→
Select range: 1 or 2
→
Input 16 digits multi
floors number [0:disable, 1: enable]
[e.g.] Set NO. 114, to access the 8th and the 16th floors.
Access programming mode
→
User Setting
→
Single Floor
→
114
→
1
→
0000000100000001
2
2
5
5
Multi floors set-up
G.Setting Up the Arming
Conditions:
1. Arming is enabled
2.Alarm system connected
Application:
1. Door open over time
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: When power is off and turn back on, reader on arming bffore power off.
Enable:
Access programming mode
→
Quit & Arming
7
Disable:
Access programming mode
→
Quit
6
Enable/Disable Arming status:
Standby Mode
Enter Program Mode
Card only
Card or Passcode
Card and Passcode
After door open
Induct valid card
→
Input 4 digit
arming code
→
Input 5 digit user address
→
Input 4 digit pass code
→ →
Input 4 digits arming code
→
Induct valid card
→
Input 4 digit
pass code
→ →
Input 4 digits
arming code
→
Door is not open
→
Input 4 digit arming code
→
Induct valid card
Manu Tree
5. Tools
1. Language
2. Master Code
3. Master Range
4. Terminal Port
5. AR401RO16 Node
6. Open Time Zone
7. Information
8. Clock Setting
9. Control Mode
0. View Events
6. Quit
7. Quit & Arming
4. Parameters[2]
1. Auto Relock
2. Egress(R.T.E)
3. Attendance
4. Master Node
5. Force Open
6. Close & Stop
7. Anti-pass-back
8. Duress Code
9. Factory Reset
0. Key (#) is Bell
3. Parameters[1]
1. Node ID
2. Auto open Zone
3. Door Relay Tm
4. Door Close Tm
5. Alarm Relay Tm
6. Alarm Delay Tm
7. Arming Delay Tm
8. Arming PWD
9. Arming Pulse
0. Auto Alarm Tm
2. User Settings
1. Password
2. Access Mode
3.Extend Options
4. Single Floor
5.Multi Floor
1. Add/ Delete
1. Add Card >ID
2. Add > RF Learn
3. Suspend > Address
4. Suspend > ID #
5. Delete > Address
6. Delete > ID #
7. Recover > Address
8. Recover > ID #
9. Antipass Group
Access programming mode
→
Tools
→
Control Mode
→
1:M4, 2:M6, 3:M8
(refer to below chart)
→
Succeeded
5
9
D.Setting up the control mode (M4/M6/M8)
※
The users up to 65,535 in
Mode 6
, since it reads
CARD CODE
(5 digits) only, unlike that Mode4/Mode8 read
SITE CODE
and
CARD CODE
(10 digits).
Mode
Networking/
Stand-Alone
Stand-Alone
Networking/
Stand-Alone
Networking/
Stand-Alone
User
Capacity
Access Mode
M4
M6
M8
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
32
No
32
11
No
11
1,200
No
1,200
1,024
(0~1,023)
65,535
(1~65,535)
1,024
(0~1,023)
Auto-show
Duty time
Event log
Capacity
120
Holidays
Anti
force
Time
Zone
Lift
Control
Anti-pass-
back
1.Card only
2.Card and PIN
(4-digit PIN)
3.Card or User address
(5-digit)
+ Individual PIN
(4-digit individual PIN)
1.Card only
2.Card and PIN
(4-digit public PIN= Arming PWD)
3.Card or PIN
(4-digit public PIN= Duress code)
1.Card only
2.Card and PIN
(4-digit individual PIN)
3.Card or PIN
(4-digit individual PIN)