V110412
Access Controller
Touch-panel Metal Housing / Illuminated Touch-panel
Enable/Disable auto open zone
Access programming mode
→
20 004 [004= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]
Enable/Disable auto open door without presenting card
Access programming mode
→
24 001 [001= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]
[e.g.] No. 154 enable the anti-pass-back, and induction into the door has not been induced to leave. When he represent into the door will become
invalid , then he needs to set the reset. Access programming mode
→
26 00154 00154 2
→
Reset
[e.g.] User address from 00152 to 00684 enable the anti-pass-back function:
26 00152 00684 0
Enable card
Access programming mode
→
26 SSSSS EEEEE N
[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]
Enable controller
Access programming mode
→
20 DDD [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Access/Exit(0=Exit; 1=Access).]
Access programming mode
→
20 128 (Please refer to function default value for details.)
[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128
N: 2 sets of auto-open zone (N=0=1st set; N=1=2nd set)
HHMMhhmm=Staring time to ending time (e.g. 08301200=08:30 to 12:00)
6543217H= 7 days of week + Holiday (Sat/Fri/Thu/Wed/Tue/Mon/Sun) (F= 0: disable; 1: enable); Holidays establish by the software.
Set up open time
Access programming mode
→
08 N HHMMhhmm 6543217H
[e.g.] To set the second time zone as 9:30 AM to 4:20 PM, Monday, Wednesday and Friday: 08 1 09301612 01010100
→
Done
M4/M8: Individual pass code
Card or PIN:
Access programming mode
→
12 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]
Card and PIN:
Access programming mode
→
13 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]
M6: Public pass word
Card or PIN:
Access programming mode
→
15 PPPP [Input 4-digit pass code, default value: 4321]
Card and PIN:
Access programming mode
→
17 PPPP [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]
Access programming mode
→
00 NNN [Node ID: 001~254]
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need
access and exit monitor.
Door will keep open after the first flashing card.There are 2 time zones supported when Stand-Alone, and 63 time zones when it connect to AR-716E.
Access programming mode
→
28 064 [064= Dual Door Control]
Controller with an reader to do the "Dual Door Control".
Access programming mode
→
04 N [N=4/6/8]
D. Set up the password
E. Dual Door Control(M4/M8)
F. Anti-pass-back(M4/M8)
G. Auto Open Time Zone
B. Chang the Node ID of Controller
C.Set up M4/M6/M8
H. Lift control
Enable
Access programming mode
→
24 002 [002= enable lift control]
[e.g.] User address NO. 168, only to the 6th and the 20th floor:
Access programming mode
→
21 00168 0 00100000
→
21 00168 2 00001000
Multi floors
Access programming mode
→
21 UUUUU S FFFFFFFF
[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)
Single floor
[e.g.] User address NO. 45, allow to access the 24th floor:
27 00045 24
Access programming mode
→
27 UUUUU FF
UUUU=User Address FF=Floor number (01~32 floor)
Connect with
AR-401RO16B
to control floors which the user will be able to access.
Set
Floor/ Stop
F
8
16
24
32
0
1
2
3
F
6
14
22
30
F
7
15
23
31
F
5
13
21
29
F
4
12
20
28
F
3
11
19
27
F
2
10
18
26
F
1
9
17
25
Please refer to below floor chart
Master Code modification
Access programming mode
→
09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] Set the Master code to be 876112, input
123456
→
09 876112876112