Soyal AR-321H Скачать руководство пользователя страница 3

SOYAL

ACCESS CONTROL SYSTEM

®

AR-321H/AR-331H/

AR-721H/AR-725H/AR-757H

V110412

AR-321H

P2

P4

P6

P1

P3

P1

P3

P2

P4

P6

P1

P2

P3

P4

P5

P1

P2

P3

P4

P5

P1

P2

P3

P4

P5

P1

P2

P3

P4

P5

P1

P2

P3

P4

P5

125kHz

125kHz

125kHz

125kHz

125kHz

13.56MHz

13.56MHz

13.56MHz

13.56MHz

13.56MHz

Main Board

Main Board

I/O Board

I/O Board

   

10 9 8 7 6 5 4 3 2 1

1

2

3

4

5

P8

P7

P1

Cable:

P7

Cable:

Wire Application

Wiegand

Beeper

LED

Wire Application

LED

Beeper

Wiegand

Pin

1

2

3

4

5

Pin

1

2

3

4

5

Color

Thin Blue

Thin Green

Pink

Brown

Yellow

Color

Brown

Yellow

White

Blue

Green

Description

Wiegand DAT:1 Input

Wiegand DAT:0 Input

Beeper Output 5V/100mA, Low 

LED Green Output 5V/20mA, Max

LED Red Output 5V/20mA, Max

Description

LED Green Output 5V/20mA, Max

LED Red Output 5V/20mA, Max

Beeper Output 5V/100mA, Low 

Wiegand DAT:1 Input

Wiegand DAT:0 Input

P2

Cable:

P8

Cable:

Wire Application

Networking 

Module

Pin

1

2

Color

Thick Green

Thick Blue

Description

RS-485(B-)

RS-485(A+)

P3

Cable:

Contact Rating: 1A 125VAC/24VDC

After S/N: 0706-XXXXXX

Wire Application

Tamper Switch

Pin

1

2

3

Color

Red

Orange

Yellow

Description

N.C.

COM

N.O.

P4

Cable:

(Optional)

(for external WG Reader)

(Directly connected at the Access controller)

Wire Application

3-PIN Connector

Pin

1

2

3

Color

Black

White

Purple

Description

GND.

Duress

Arming/ Security trigger signal 

P5

Cable:

Wire Application

Door bell

Arming

Duress

LED indicator

Pin

1

2

3

4

Color

Brown White

Red White

Yellow White

Green White

Description

BE Output

AR Output/ Security trigger signal Output

DU Output/ TTL out

Hi input/ Green light brighten

P6

Cable:

AR-321H

AR-721H

AR-331H

AR-725H

AR-757H

Wire Application

Lock Relay

Common-COM-Point

Door contact

Exit Switch

Alarm Relay

Power

Wire Application

Power

Exit Switch

Networking Module

Lock Relay

Networking Module

Tamper Switch

Alarm Relay

Door contact

Pin

1

2

3

4

5

6

7

8

Pin

1

2

3

4

5

6

7

8

9

10

Color

Blue White

Purple White

White

Orange

Purple

Gray

Thick Red

Thick Black

Color

Black

Red

 Purple

Green

White

Blue

Yellow

Brown

Gray

Orange

Description

(N.O.) DC24V1Amp

(N.C.) DC24V1Amp

(COM) DC24V1Amp

Negative Trigger Input

Negative Trigger Input

Low output; Max 12V/100mA (Open Collector)

DC Power 12V

DC Power 0V

Description

DC Power 0V

DC Power 12V

Negative Trigger Input

RS-485(B-)

Low output; Max 12V/100mA (Open Collector)/

Security trigger signal Output

RS-485(A+)

N.O.

COM

Low output; Max 12V/100mA (Open Collector)

Negative Trigger Input

Connector Table

AR-321H
AR-331H
AR-721H
AR-725H
AR-757H

Connectors Comparison

P1 P2 P3 P4

(     

Optional

)

P5

P7 P8
P1 P2 P3 P4

(     

Optional

)

P5

P1 P2 P3 P4

(     

Optional

)

P5

P1 P2 P3 P4 P6

Notice

The communication wires and power line should NOT be bound in the same conduit or tubing.

Don’t equip controller and lock with the same power supply. The power for controller may be unstable when the lock is activating, that may make 
the controller malfunction.
The standard installation: Door relay and lock use the same power supply, and controller use independent power supply.

Use AWG 22-24 Shielded Twist Pair to avoid star wiring.

1.Tubing:
2.Wire selection:
3.Power supply:

Содержание AR-321H

Страница 1: ...725X 1 Product 1 Product 1 Product 1 Product 1 Products 1 Products 1 Products 3 User Guide 2 Optional 2 User Guide 2 User Guide 2 User Guide 2 User Guide 2 User Guide 4 Terminal Cables 3 Terminal Cab...

Страница 2: ...the metal casing back and lock it with security screw Finally put the Protection plug into the hole Turn on the power and LED will light and beep will sound Pull the cables from the square hole of th...

Страница 3: ...White Green White Description BE Output AR Output Security trigger signal Output DU Output TTL out Hi input Green light brighten P6 Cable AR 321H AR 721H AR 331H AR 725H AR 757H Wire Application Lock...

Страница 4: ...nel Strengthen security with AR 721RB Connect to Access Control for Connect to arming tools for Connect to Reader Alarm Alarm Tamper Alarm Controller Reader Controller Controller AR 716E Controller Co...

Страница 5: ...sequential tags 62312 62332 Access programming mode 19 00101 00120 Close Tag into RF Area only use the tag NO 62312 OK Tag Information SITE CODE CARD CODE SITE CODE CARD CODE Mode6 At this mode User...

Страница 6: ...User address 00001 and pass code 1234 input 13 00001 1234 M6 Public pass word Card or PIN Access programming mode 15 PPPP Input 4 digit pass code default value 4321 Card and PIN Access programming mod...

Страница 7: ...thout cards at auto open zone Alarm Output Lift Control Stop Alarm by door close or by push button Door bell 0 Disable 0 Alarm Output 0 None 0 Disable Networking Stand Alone Networking Stand Alone Net...

Страница 8: ...ay time 001 600 1 600 sec SSSSS EEEEE 00000 01023 00000 03000 for AR 725H SSSSS Starting user address EEEEE Ending user address N 0 1st time zone 1 2nd time zone HHMM Starting time hhmm ending time i...