Soyal AR-101-H Скачать руководство пользователя страница 6

V221024

- 6 -

Access Controller

  

Command List

   

Function

Enter program mode

Master code setting

Suspend tag
Delete tag
Add a batch of sequential cards by 
inputting card number (M6)
Recover the suspended cards(M4/M8)

Card number modification(M4/M8)

Add card by presenting(M4/M8)

Add/Delete tag by presenting(M6)
Delete all tags

Enable/Disable Door open for any Tag

Mifare tag / card format (Optional)
(M4/M8)

Administrator Card setting
(M4/M8)

Enable the security trigger signal 
( with AR-721RB)
Control mode setting

Card or PIN (M4/M8)

Modify the PIN with user address, change 

the pass mode into Card or PIN

Card and PIN (M4/M8)

Modify the PIN with user address, change 

the pass mode into Card and PIN

Card or PIN(M6)

Set up the mutual PIN in Card or PIN mode

Card and PIN(M6)

Set up the mutual PIN in Card and PIN mode

Setting duress PWD(M4/M8)

Setting arming PWD(M4/M8)

Node ID setting 

(Connected to 716E)

(M4/M8)

Node ID setting 

(Connected to the PC directly 

without 716E)

 (M4/M8)

Door Relay Time setting

Alarm Relay Time setting

Arming Delay Time setting

Alarm Delay Time setting

Arming Pulse Time setting
Door Close Time

Controller time clock setting

Same tag reading interval time

Command

     PPPPPP
09     PPPPPPRRRRRR

10     SSSSS     EEEEE
10     SSSSS     EEEEE

11     SSSSS     EEEEE

11     SSSSS     EEEEE

16     UUUUU     SSSSSCCCCC

19     UUUUU     QQQQQ
22     N
29     29

0

01     N

07     SSSSS     EEEEE

34      ???

04     N

12     UUUUU      ????

13     UUUUU      ????

15      ????

17      ????

15      ????

17      ???? 

00     NNN

00     NNN     VVV     nnn

02     TTT

03     TTT

05     TTT

06     TTT

14     TTT
18     TTT
25     YYMMDDHHmmss
31     TTTT

Description

PPPPPP

=Master Code, default value=

123456

PPPPPP

=6-digit new master code

RRRRRR

=Reconfirm the new master code

     =Suspend         =Delete;

SSSSS

=Starting User Address

EEEEE

=Ending User Address

SSSSS

=Starting card number 

EEEEE

=Ending card number

SSSSS

=Starting card number 

; 

EEEEE

=Ending card number

UUUUU

= User Address; 

SSSSS

=5-digit site code; 

CCCCC

= 5-digit card code

UUUUU

=User Address; 

QQQQQ

=Card quantity (00001: 

for adding a single card or a batch of random numbering cards)

N

=0(Delete tag); 

N

=1(Add tag)

After enabling Door Open For Any Tag, all cards in same 
frequency as controller can pass directly.

N

:

0=ISO14443A

1=ISO14443B

2=ISO15693

3=I Code1

4=I Code2

PS.1. Please select the transmission standard first. 

      2. Ensure both reader and card using the same 

          transmission standard.

SSSSS-EEEEE=00000-00255 
(Administrator Card can enter the program mode after 
present the card and press       in 3 seconds, 
also can exit program mode by present the card.)

Change the "Arming"  to the security trigger signal, 
when controller is connected with AR-721RB.

Please refer t

Compound Command Function List 

for details.

N=4: M4; N=6: M6; N=8: M8
Pass by Card or PIN; 

UUUUU

=User Address;

????

=4-digit PIN (0001~9999); 

0000=Set as card only
Pass by Card and PIN; 

UUUUU

=User Address;

????

=4-digit PIN (0000~9999)

????

=4-digit PIN(0001~9999 ; default value=4321)

????=

4-digit PIN(0001~9999 ; default value=1234)

0000= Set as card only

????

=4-digit PIN(0001~9999 ; default value=4321)

The Duress Code 0000 means that disable Duress 

Function and the default value is set as 0000 already.

????

=4-digit PIN(0001~9999 ; default value=1234)

NNN

=Node ID of Access Controller (range: 001~016)

NNN

=Node ID of Access Controller (range: 001~254) 

VVV

=Virtual 716E Node ID, nnn=Door number (range:001~254)

TTT

=Door relay time   000= Output continuously

                                     001~600=1~600 sec.

                                     601~609=0.1~0.9 sec.

TTT

=Alarm relay time  000= Output continuously  

001~600=1~600 sec.

TTT

=the buffer time before entering arming mode  

001~600=1~600 sec.

TTT

=the buffer time before the alarm is activated  

001~600=1~600 sec.

TTT

=Arming output time; 000=output continuously 

001~250=0.1~2.5 sec.

TTT

=Door Close Time: 001~600=1~600 sec.; 

default value: 15 sec. 

YYMMDDHHmmss

=Year/ Month/ Day/ Hour/ Min./ Sec.

TTTT

=10~6000 (Base on 10ms, range from 10 to 6000; 

default value: 1 sec.

0100)

9

9

(07        Starting User Address        Ending User Address        )

Master 

Code 

Setting

Card 

Setting 

Commands

Additional

Card Function

Setting

Access Mode

Setting

Arming /Duress

Function

 Setting

(M4/M8 applicable

, but not M6)

Node ID

Setting

Time /Delay

 Setting

Содержание AR-101-H

Страница 1: ... Edge Indicator Function Wire Color Description RS 485 1 Thick Green RS 485 B 2 Thick Blue RS 485 A Function Wire Color Description Lock Relay 1 Blue White N O DC24V1Amp 2 Purple White N C DC24V1Amp 3 White COM DC24V1Amp Door Contact 4 Orange Negative Trigger Input Exit Switch 5 Purple Negative Trigger Input Alarm 6 Gray Transistor Output Max 12V 100mA Open Collector Active Low Power 7 Thick Red D...

Страница 2: ... RTE PB Door Sensor 1 2 1 2 3 4 J3 WG Reader Ex Keyboard Optional AR WG KEYBOARD Door Contact Request To Exit 1 FORM C Relay Output Module AR 821RB Alarm Wiring USB Converter TCP IP Converter Power Electric Bolt AR 1207 or Magnetic Lock Cabinet Lock or Electric Strike a DMET 101PJ01 Slim US Type b DMET 101PJ02 Rectangle US Type c DMET 101PJ03 Square EU Type Remove the black ABA Screw Nut from Butt...

Страница 3: ... presented again it will exit programming mode Green Blue Plug in cable the wire connection is as below figure After connection then have power transmission to controller Below programming is for AR 101 H only P2 Mode4 Mode6 Mode8 Mode 6 the number of users up to 65535 since it reads CARD CODE 5 digits only unlike that Mode4 Mode8 read SITE CODE and CARD CODE 10 digits If Access Mode setting to us...

Страница 4: ...ing Setting and Alarm Trigger Procedure Arming Mode Disarming Mode Triggering Alarm Condition Triggering Alarm Condition VS abnormal door position door open too long door is forced openg door is forced openg Door Relay TM Arming Delay TM Enable Arming Alarm Relay TM Door Close TM Alarm Delay TM Enable Arming Status Alarm Trigger Door open Green Led Flash Quickly Red Led Flash Quickly Alarm trigger...

Страница 5: ...hout Enter Programming Mode Standby Mode Enter Arming Code default value of arming PWD is 1234 34 Function Selection Value Application Default Value Enable the RF after door sensor closed to GND Invalid card to activate alarm relay Turn off all sounds of beeper Mute the sounds of egress button RTE Reserved Keep beeing while arming is enabled Door relay connected to AR 721RB suited to models withou...

Страница 6: ...1 for adding a single card or a batch of random numbering cards N 0 Delete tag N 1 Add tag After enabling Door Open For Any Tag all cards in same frequency as controller can pass directly N 0 ISO14443A 1 ISO14443B 2 ISO15693 3 I Code1 4 I Code2 PS 1 Please select the transmission standard first 2 Ensure both reader and card using the same transmission standard SSSSS EEEEE 00000 00255 Administrator...

Страница 7: ...his function ex AR 725 H UUUUU User Address S 4 sets of lift control 0 3 FFFFFFFF 8 assigned floor F 0 Disable 1 Enable NNN site number TTT relay time 000 600 1 600 sec UUUUU User Address FF Floor 01 32 floor Command 20 24 28 08 N HHMMhhmm 7123456H 26 SSSSS EEEEE N simultaneously 24 002 21 UUUUU S FFFFFFFF 23 NNN TTT 27 UUUUU FF Controller Additional Function Setting Lift Control Setting Exit Prog...

Отзывы: