Soyal AR-101-H Скачать руководство пользователя страница 4

V221024

- 4 -

   

Access Controller

D. Setting Up the Arming 

[Only for connect to external K-series reader]

M4/M8: Individual pass code

Card or PIN:

 

Access programming mode

 → 

12     UUUUU      ????       [e.g. User address: 00001 and pass code: 1234, input 12     00001     1234     ]

Card and PIN:

 

Access programming mode

 → 

13     UUUUU      ????       [e.g. User address: 00001 and pass code: 1234, input 13     00001     1234     ]

M6: Public pass word
Card or PIN:

 

Access programming mode

 → 

15      ????       [Input 4-digit pass code, default value: 4321]

Card and PIN:

 

Access programming mode

 → 

17      ????       [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]

B. Set up the password 

[Only for connect to external K-series reader]

C. Lift control

Enable

Access programming mode

 → 

24     002       [002= enable lift control]

Connect with 

AR-401RO16B

 to control floors which the user will be able to access.

[e.g.] User address NO. 168, only to the 6th and the 20th floor:

        Access programming mode

 → 

21     00168     0     00100000     

 → 

21     00168     2     00001000

Multi floors

Access programming mode

 → 

21     UUUUU     S     FFFFFFFF

[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)

Single floor

[e.g.] User address NO. 45, allow to access the 24th floor:

 

27     00045     24

Access programming mode

 → 

27     UUUUU     FF

UUUU=User Address FF=Floor number (01~32 floor)

Set

Floor/ Stop

F

8

16

24

32

0

1

2

3

F

6

14

22

30

F

7

15

23

31

F

5

13

21

29

F

4

12

20

28

F

3

11

19

27

F

2

10

18

26

F

1

9

17

25

1.

Normal Opening

 

2.

Abnormal Opening

 

Arming Setting and Alarm Trigger Procedure : 

Arming Mode

Disarming Mode

T

riggering Alarm 

Condition:

T

riggering Alarm

 Condition:

VS

abnormal door 

position

door open to

o

long

door is for

ced

openg

door is for

ced

openg

Door Relay TM

Arming Delay TM

Enable Arming

Alarm Relay TM

Door Close TM

Alarm Delay TM

Enable

Arming Status

Alarm Trigger

Door open 

Green Led Flash Quickly

Red Led Flash Quickly

Alarm trigger

Green Led Flash

Standby Mode

(Arming is not enable)

Enable

Arming Status

Alarm Trigger

Green Led Flash Quickly

Red Led Flash Quickly

Green Led Flash

Arming Delay TM

Enable Arming

Standby Mode

(Arming is not enable)

Alarm Relay TM

Alarm Delay TM

Alarm trigger

In the security management of access control system, the controller or reader status is divided into Standby Mode or Disarming Mode and Arming 

Mode. The conditions for triggering the alarm in these two modes is different, as shown in the following comparison:

Alarm conditions:

1. Door is forced open

Application:
1. Door open too long

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal

: Arming is enabled and the power is suddenly off then on.

The default value of access function of M6 is Card and PIN, it will have 3 beeps for hinting you input PIN 

number after card presentation. Access function modification please refer the table below:

17      ????           15      0000

????=4-digit PIN(0001~9999 ; default value=1234)

????=4-digit PIN(0001~9999 ; default value=4321)

17      0000           15      0000
17      0000           15      ????

Card and PIN
Card only
Card or PIN

Access Mode

Command

Description

Содержание AR-101-H

Страница 1: ... Edge Indicator Function Wire Color Description RS 485 1 Thick Green RS 485 B 2 Thick Blue RS 485 A Function Wire Color Description Lock Relay 1 Blue White N O DC24V1Amp 2 Purple White N C DC24V1Amp 3 White COM DC24V1Amp Door Contact 4 Orange Negative Trigger Input Exit Switch 5 Purple Negative Trigger Input Alarm 6 Gray Transistor Output Max 12V 100mA Open Collector Active Low Power 7 Thick Red D...

Страница 2: ... RTE PB Door Sensor 1 2 1 2 3 4 J3 WG Reader Ex Keyboard Optional AR WG KEYBOARD Door Contact Request To Exit 1 FORM C Relay Output Module AR 821RB Alarm Wiring USB Converter TCP IP Converter Power Electric Bolt AR 1207 or Magnetic Lock Cabinet Lock or Electric Strike a DMET 101PJ01 Slim US Type b DMET 101PJ02 Rectangle US Type c DMET 101PJ03 Square EU Type Remove the black ABA Screw Nut from Butt...

Страница 3: ... presented again it will exit programming mode Green Blue Plug in cable the wire connection is as below figure After connection then have power transmission to controller Below programming is for AR 101 H only P2 Mode4 Mode6 Mode8 Mode 6 the number of users up to 65535 since it reads CARD CODE 5 digits only unlike that Mode4 Mode8 read SITE CODE and CARD CODE 10 digits If Access Mode setting to us...

Страница 4: ...ing Setting and Alarm Trigger Procedure Arming Mode Disarming Mode Triggering Alarm Condition Triggering Alarm Condition VS abnormal door position door open too long door is forced openg door is forced openg Door Relay TM Arming Delay TM Enable Arming Alarm Relay TM Door Close TM Alarm Delay TM Enable Arming Status Alarm Trigger Door open Green Led Flash Quickly Red Led Flash Quickly Alarm trigger...

Страница 5: ...hout Enter Programming Mode Standby Mode Enter Arming Code default value of arming PWD is 1234 34 Function Selection Value Application Default Value Enable the RF after door sensor closed to GND Invalid card to activate alarm relay Turn off all sounds of beeper Mute the sounds of egress button RTE Reserved Keep beeing while arming is enabled Door relay connected to AR 721RB suited to models withou...

Страница 6: ...1 for adding a single card or a batch of random numbering cards N 0 Delete tag N 1 Add tag After enabling Door Open For Any Tag all cards in same frequency as controller can pass directly N 0 ISO14443A 1 ISO14443B 2 ISO15693 3 I Code1 4 I Code2 PS 1 Please select the transmission standard first 2 Ensure both reader and card using the same transmission standard SSSSS EEEEE 00000 00255 Administrator...

Страница 7: ...his function ex AR 725 H UUUUU User Address S 4 sets of lift control 0 3 FFFFFFFF 8 assigned floor F 0 Disable 1 Enable NNN site number TTT relay time 000 600 1 600 sec UUUUU User Address FF Floor 01 32 floor Command 20 24 28 08 N HHMMhhmm 7123456H 26 SSSSS EEEEE N simultaneously 24 002 21 UUUUU S FFFFFFFF 23 NNN TTT 27 UUUUU FF Controller Additional Function Setting Lift Control Setting Exit Prog...

Отзывы: