Soyal AR-101-H Скачать руководство пользователя страница 1

SOYAL

®

AR-101-H/U

V221024

ACCESS & INDUSTRIAL CONTROL

- 1 -

8

7

2

1

6

5

1

2

3

4

4

3

2

1

ON

1    2

  

AR-WG-KEYBOARD

AR-101-H/U

CN1

CN2

AR-721-RB

DMET-101PJ

AR-821-RB

A

B

ON

1    2

A

B

  

CN2

CN1

J3

Feature

Content

Connector Table

1

Product

4

Optional (panel)

3

Black ABS

5

Optional(only 101-H)

2

Terminal Cables

or

Front

Back

Selectable working frequencies: 125KHz/13.56MHz
From the DIP switch to select to be RS485 or WG output reader
Flexible to integrate with SOYAL or other access control system
Interface of the Proximity Reader have WG26/34 (By order)
Elegant design with colorful Edge Indicator
Flush-Mounted Design gives neat installation

Dip-switch must adjust at 2nd layer of mainboard.   

    Highly suggest to fixed WG34/26 before order

Step 1.

Open lightly the upper board 

cover with screwdriver

How to adjust dip-switch:

Step 2.

Adjust the DIP switch according to 

the function and put upper cover 

back on the upper board

AR-101-U (RS485/WG)

AR-101-H 

Selectable working frequencies: 13.56MHz

Including the input of door contact, offering the alarm system of both 

door opening too long and being forced to open
Built-in Multi-Output: Door Lock/ Alarm/ Security trigger signal
Have the "MASTER CARD" functions, convenient operation
Mini Flush-Mounted design gives neat installation
Elegant design with colorful Edge Indicator

Function

Wire

Color

Description

RS-485

1

Thick Green RS-485(B-)

2

Thick Blue

RS-485(A+)

Function

Wire

Color

Description

Lock Relay

1

Blue White (N.O.) DC24V1Amp

2

Purple White (N.C.) DC24V1Amp

3

White

(COM) DC24V1Amp

Door Contact

4

Orange

Negative Trigger Input

Exit Switch

5

Purple

Negative Trigger Input

Alarm

6

Gray

Transistor Output Max. 12V/100mA 

(Open Collector Active Low)

Power

7

Thick Red DC 9~24V

8

Thick Black DC 0V

CN1

CN1

AR-101-H/U

AR-101-H

AR-101-U Dip-switch &

Wire

Color

Function

Description

 

RS-485 Mode/

Polling Mode 

(Connected to AR-716-E16)

WG Mode

Dip-switch-SW1

---

---

ON

OFF

ON

OFF

Dip-switch-SW2

---

---

ON

ON

OFF

OFF

Description

---

---

Auto-open Time Zone

WG34

(default)

WG26

Auto Open with 

swiping 1st valid 

card at Auto-open 

Time Zone

Auto-open door at 

auto open zone

CN1 Cable

1

Blue White ---

WG Output

WG DATA 1 Output

2

Green White ---

WG DATA 0 Output

3

White

Door Lock Output

---

Transistor Output Max. 24V/1.5A 

(Open Collector Active Low)

4

Orange

Door Sensor

LED R 

Negative Trigger Input

5

Purple

Exit Button

LED G

Negative Trigger Input

6

Gray

Buzzer

Transistor Output Max. 12V/100mA 

(Open Collector Active Low)

7

Thick Red Power

DC 12V

8

Thick Black

DC 0V

CN2

2PIN Cable

8PIN Cable

8PIN Cable

Extenal Relay :

Master Card :

(Keyless editing)

Wiegand Keyboard :

※ 

Dip-switch is only available for AR-101-U

  J3

4PIN Cable

Function

Wire

Color

Description

Wiegand Reader/

Ex. Keyboard

1

Thick Red DC 9~24V

2

Thick Black DC 0V

3

Thick Blue

Wiegand DAT:1 Input

4

Thick Green Wiegand DAT:0 Input

AR-101-H/U

Содержание AR-101-H

Страница 1: ... Edge Indicator Function Wire Color Description RS 485 1 Thick Green RS 485 B 2 Thick Blue RS 485 A Function Wire Color Description Lock Relay 1 Blue White N O DC24V1Amp 2 Purple White N C DC24V1Amp 3 White COM DC24V1Amp Door Contact 4 Orange Negative Trigger Input Exit Switch 5 Purple Negative Trigger Input Alarm 6 Gray Transistor Output Max 12V 100mA Open Collector Active Low Power 7 Thick Red D...

Страница 2: ... RTE PB Door Sensor 1 2 1 2 3 4 J3 WG Reader Ex Keyboard Optional AR WG KEYBOARD Door Contact Request To Exit 1 FORM C Relay Output Module AR 821RB Alarm Wiring USB Converter TCP IP Converter Power Electric Bolt AR 1207 or Magnetic Lock Cabinet Lock or Electric Strike a DMET 101PJ01 Slim US Type b DMET 101PJ02 Rectangle US Type c DMET 101PJ03 Square EU Type Remove the black ABA Screw Nut from Butt...

Страница 3: ... presented again it will exit programming mode Green Blue Plug in cable the wire connection is as below figure After connection then have power transmission to controller Below programming is for AR 101 H only P2 Mode4 Mode6 Mode8 Mode 6 the number of users up to 65535 since it reads CARD CODE 5 digits only unlike that Mode4 Mode8 read SITE CODE and CARD CODE 10 digits If Access Mode setting to us...

Страница 4: ...ing Setting and Alarm Trigger Procedure Arming Mode Disarming Mode Triggering Alarm Condition Triggering Alarm Condition VS abnormal door position door open too long door is forced openg door is forced openg Door Relay TM Arming Delay TM Enable Arming Alarm Relay TM Door Close TM Alarm Delay TM Enable Arming Status Alarm Trigger Door open Green Led Flash Quickly Red Led Flash Quickly Alarm trigger...

Страница 5: ...hout Enter Programming Mode Standby Mode Enter Arming Code default value of arming PWD is 1234 34 Function Selection Value Application Default Value Enable the RF after door sensor closed to GND Invalid card to activate alarm relay Turn off all sounds of beeper Mute the sounds of egress button RTE Reserved Keep beeing while arming is enabled Door relay connected to AR 721RB suited to models withou...

Страница 6: ...1 for adding a single card or a batch of random numbering cards N 0 Delete tag N 1 Add tag After enabling Door Open For Any Tag all cards in same frequency as controller can pass directly N 0 ISO14443A 1 ISO14443B 2 ISO15693 3 I Code1 4 I Code2 PS 1 Please select the transmission standard first 2 Ensure both reader and card using the same transmission standard SSSSS EEEEE 00000 00255 Administrator...

Страница 7: ...his function ex AR 725 H UUUUU User Address S 4 sets of lift control 0 3 FFFFFFFF 8 assigned floor F 0 Disable 1 Enable NNN site number TTT relay time 000 600 1 600 sec UUUUU User Address FF Floor 01 32 floor Command 20 24 28 08 N HHMMhhmm 7123456H 26 SSSSS EEEEE N simultaneously 24 002 21 UUUUU S FFFFFFFF 23 NNN TTT 27 UUUUU FF Controller Additional Function Setting Lift Control Setting Exit Prog...

Отзывы: